Home Companies Newscen Biopharm Co., Limited

ISO Ambient Storage 40 Kits HIV Rapid Test Cassette

Newscen Biopharm Co., Limited
Active Member

Contact Us

[China] country

Address: No. 65 Sixth Ave .,TEDA Tianjin , 300457 P. R. China

Contact name:Randy.Zhang

Inquir Now

Newscen Biopharm Co., Limited

ISO Ambient Storage 40 Kits HIV Rapid Test Cassette

Country/Region china
City & Province tianjin tianjin
Categories Dyestuff Intermediates
InquireNow

Product Details

HIV(1+2) Antibody Rapid Test Kit


For qualitative detection of HIV(1+2) Antibodies in serum/plasma and whole Blood

 

Home Use HIV1+2 Antibody Screening Test Colloidal Gold For Sexually Transmitted Diseases
 
Main Features


► Sensitivity: 100%
► Specificity: Higher than 99%
► Simple: No Instrument Required
► Ambient Storage
► Reliable: able to differentiate HIV Type I and Type II
► Certified by Authoritative Certification
► Unique 3-line Patented Design
► Winner of "the 2008 National HIV Antigen Diagnostic Kit for Clinical Performance Assessment"
 
Intended Use


The HIV-1/2 Rapid Diagnostic Test (RDT) is a qualitative test for the detection of antibodies to Human Immunodeficiency Virus type 1 and 2 (HIV-1/2) in human serum/plasma. It is considered as an initial screening test for HIV-1/2 antibodies. All positive specimens must be confirmed with Western Blot or other qualified EIA.


 


Principle


HIV-1/2 RDT is a chromatographic immunoassay (CIA) for the detection of antibodies to HIV-1/2 in human serum/plasma. HIV-1/2 specific antigens are precoated onto membrane as a capture reagent on the test region.
 
During the test, specimen is allowed to react with the colloidal gold particles, which have been labeled with HIV-1/2 specific antigens. Antibodies to HIV-1/2, if present, a red colored band will develop on the membrane in proportion to the amount of HIV-1/2 antibodies present in the specimen.
 
Absence of this red colored band in the test region suggests a negative result. To serve as a procedural control, red colored band in the control region will always appear regardless the presence of antibodies to HIV-1/2.
 
Assay Procedure


► Place the test cassette on flat surface. Before unseal the pouch, allow the test cassette to reach room temperature(4-30°C) .Use it immediately once unsealed.
► Open the pouch and add 1drop(30-40uL) of specimen into the sample well(S) .
► When the specimen is completely absorbed, slowly add1drop(45-55pL) of diluent buffer vertically into the sample well(s) .
► Avoid dropping specimen or diluent buffer in the observation window.
► Do not allow the diluent buffer bottle touch the sample well when dropping the diluent buffer so as to prevent the cross contamination with the specimen.
► Observe the result between 15-30 minutes after the diluent buffer added.
 
Interpretation of Results



► Negative: No apparent band in the test region (1 and 2), only one red band appears in the control region (C). This indicates that no HIV1/2 antibodies have been detected.
► Positive: In addition to the band in the control region (C), other one or two red bands will appear in the test region (1 and 2). This indicates that the specimen contains HIV1/2 antibodies.
► Invalid: If no band appears in the control region(C), regardless of the presence or absence of line in the test region (1 and 2). It indicates a possible error in performing the test. The test should be repeated using a new device.
 


Reagents and Materials Provided


Each kit contains:
► 40 test cassettes(individually pouched)
► One bottle of diluent buffer(5ml)
► 40 disposable plastic droppers
► Each pouch contains one cassette with one desiccant bag
► Instruction for use
 
Materials Required But Not Provided


► Timer or stopwatch
► Biohazard disposal container
► Blood collection devices, for the testing of venous whole blood, serum or plasma
► Disposable gloves
 
For finger stick samples, the following materials are required:
Alcohol pad
Sterile lancet
Sterile gauze or cotton
 
Warning


For Invitro Diagnostic Use ONLY
Read the package insert completely before use. It is very important that the correct procedure is followed. Fail to add the patient sample may lead to a false negative result (i.e.a missed positive) .
 
Storage


Newscen HIV(1+2) Antibody Rapid Test can be stored at room temperature(4-30℃, do not freeze) for 24 months from the date of manufacture.
Keep the test cassette in sealed pouch until use. Once you have taken the test cassette out of the pouch, perform the test as early as possible(within 1hour) to avoid test cassette from becoming moist. Do not use the test beyond the indicated expiration date.
The diluent buffer should be stored at room temperature(4-30℃, do not freeze) .
 

 

Hot Products

Where To Get Tested For Covid 19 Throat Swab Or Nasal Swab Screening Test Coronavirus Ag Rapid Test ...
CE TUV Certification Antigen And Antibody Coronavirus Test PCR Antigen Testing For SARS-CoV-2 COVID...
Home Use COVID-19 Antigen Rapid Test COVID-19 Rapid Antigen Test Swab How To Get Tested For Covid 19 ...
Where To Get Tested For Covid 19 Throat Swab Or Nasal Swab Screening Test Coronavirus Ag Rapid Test ...
Hot Sale In Vitro Diagnostic Coronavirus Antigen Rapid Test Cassette (Swab) Used At Home COVID-19 ...
Spanish CE Certification Home Use Coronavirus Ag Rapid Test Cassette High Accurate COVID-19 Antigen ...