Home Companies Newscen Biopharm Co., Limited

99% Tuberculosis Rapid Test Kit

Newscen Biopharm Co., Limited
Active Member

Contact Us

[China] country

Address: No. 65 Sixth Ave .,TEDA Tianjin , 300457 P. R. China

Contact name:Randy.Zhang

Inquir Now

Newscen Biopharm Co., Limited

99% Tuberculosis Rapid Test Kit

Country/Region china
City & Province tianjin tianjin
Categories Dyestuff Intermediates
InquireNow

Product Details

TB (Tuberculosis) Rapid Dignostic Cassette

 

For the Qualitative Detection of Antibody against Tuberculosis in serum and plasma

 

Main Features

 

► Sensitivity: 100%

► Specificity: Higher than 99%

► Simple Use: No Instrument Required

► Ambient storage.

► Reliable Performance

► Certified by Authoritative Certification

► Winner of "the National Rapid Diagnostic Kit for Clinical Performance Assessment"

 

Intended Use


The TB Rapid Test is a chromatographic immunoassay (CIA) for direct qualitative detection of Tuberculosis antibody in human serum or plasma

 

 

Principle

 

Tuberculosis remains an important socio-economical and medical problem throughout the world. According to the Centers for Disease Control, the incidence of TB is expected to increase from 7.5 million cases per year in 1995 to 11.9 million in 2005. The case fatality rate is estimated at 55% for untreated people and 15% for the treated patients.

 

The commonly used diagnostic tests for the tuberculosis such as sputum examination of acid fast bascilli, culture of sputum or other fluids, the tuberculin skin test and radiological investigations do not achieve the required diagnostic sensitivity.

 

TB is a chromatographic immunoassay test for the detection of TB antibody in human serum or plasma. Specific antigens are pre-coated onto membrane as a capture reagent on the test region. During the test, specimen is allowed to react with the antigens firstly. The chasing buffer mixed with specific mouse anti-human antibody, which is conjugated with colloidal gold, will flow up the membrane. If TB antibody is present, a red colored band will appears on the test region of membrane.

 

Absence of this red colored band in the test region suggests a negative result. To serve as a procedural control, a red colored band in the C region will always appear regardless of the presence or absence of TB antibody.

 

 

Materials Supplied

 

► Test Cassette

► Pipette Dropper

► Desiccant

► Buffer

► Package Insert

 

Material Required But Not Provided


► Clock or Timer
► Specimen collection containers.
► Timer
► Lancets (for fingerstick whole blood only)
► Centrifuge (for plasma only)

 

Sample Collection and Preparation

 

Plasma

► Have a certified phlebotomist collect whole blood into a purple, blue or green top collection tube (containing EDTA, citrate or heparin, respectively) by veinpuncture.

► Separate the plasma by centrifugation.

► Carefully withdraw the plasma for testing, or label and store it at 2-8°C for up to 5 days. Plasma may be frozen at -20℃ for up to 3 months.

 

Serum

► Have a certified phlebotomist collect whole blood into a red top collection tube (containing no anticoagulants) by veinpuncture.

► Allow the blood to clot.

► Separate the serum by centrifugation.

► Carefully withdraw the serum for testing or label and store it at 2-8°C for up to 5 days. Serum may be frozen at -20℃ for up to 3 months.

 

 

Interpretation of Results

 

 

► Negative: No apparent band in the test region (T), a pink-colored band appears in the control region (C). This indicates that no TB antibody has been detected.


► Positive: In addition to a pink-colored band in the control region (C), a pink-colored band will appear in the test region (T). This indicates that the specimen contains TB.


► Invalid: If no band appears in the control region (C), regardless of the presence or absence of line in the test region (T). It indicates a possible error in performing the test. The test should be repeated using a new device.


Warnings and Precautions


► For professional In Vitro diagnostic use only.
► Warning: the reagents in this kit contain sodium azide which may react with lead or copper plumbing to form potentially explosive metal azides. When disposing of such reagents, always flush with large volumes of water to prevent azide build-up.
► Do not use it if the tube pouch is damaged or broken.
► Test is for single use only. Do not re-use under any circumstances.
► Handle all specimens as if they contain infectious agents. Observe established standard procedure for proper disposal of specimens
► Wear protective clothing such as laboratory coats, disposable gloves and eye protection when specimens are assayed.
► Humidity and temperature can adversely affect results.

 

 

Storage and Stability


All reagents are ready to use as supplied. Store unused test device unopened at 2°C-30°C.


If stored at 2°C-8°C, ensure that the test device is brought to room temperature before opening. The test device is stable through the expiration date printed on the sealed pouch. Do not freeze the kit or expose the kit over 30°C.

 

Hot Products

Where To Get Tested For Covid 19 Throat Swab Or Nasal Swab Screening Test Coronavirus Ag Rapid Test ...
CE TUV Certification Antigen And Antibody Coronavirus Test PCR Antigen Testing For SARS-CoV-2 COVID...
Home Use COVID-19 Antigen Rapid Test COVID-19 Rapid Antigen Test Swab How To Get Tested For Covid 19 ...
Where To Get Tested For Covid 19 Throat Swab Or Nasal Swab Screening Test Coronavirus Ag Rapid Test ...
Hot Sale In Vitro Diagnostic Coronavirus Antigen Rapid Test Cassette (Swab) Used At Home COVID-19 ...
Spanish CE Certification Home Use Coronavirus Ag Rapid Test Cassette High Accurate COVID-19 Antigen ...