Home Companies Shenzhen Zhongguanda Technology Co., Ltd.

High Power High Frequency Online UPS Battery Backup Power Supply

Shenzhen Zhongguanda Technology Co., Ltd.
Active Member

Contact Us

[China] country

Address: 708, No.218, Changchun Road, Shangcun Community, Gongming Street, Guangming District, Shenzhen

Contact name:Mark

Inquir Now

Shenzhen Zhongguanda Technology Co., Ltd.

High Power High Frequency Online UPS Battery Backup Power Supply

Country/Region china
City & Province shenzhen
Categories Uninterrupted Power Supply (UPS)
InquireNow

Product Details

High Power High Frequency Online UPS Battery Backup Power Supply

 

High Frequency High Power Ups Online Ups Backup Power Supply With Battery​

 

Routine Maintain

To make sure UPS work normal, appropriate maintenance should be schedule periodically, below items should be checked:.

 

Check UPS running status.

If the utility power is normal, UPS should work in line mode or in battery mode. And there is no warning or fault indication.

 

Check UPS running mode switch.

Cut off the line input to simulate the utility power interrupt, UPS should transfer to battery mode, and connect the line input, UPS return to line mode again.

 

Check UPS panel.

Check UPS panel display if it is consistent with UPS running mode

 

 

 

 

Specification​
Model item1K(R)1K(R)S2K(R)2K(R)S3K(R)3K(R)S6K6K(R)S10K10K(R)S
Rated power1000VA/800W2000VA/1600W3000VA/2400W6kVA/5.4kW10kVA/9kW
AC InputInput systemSingle phase (L/N+PE)
 Nominal voltage

HV: 208/220/230/240Vac

LV:100/110/120/127Vac

 Frequency50/60Hz
 Voltage range

HV: 90~300VAC±5VAC

LV: 60-145Vac±3VAC

 Frequency range(40~70)±0.5Hz
 Input power factor>0.99
 Bypass Voltage Range

HV: 115~285VAC×(1±3%)

LV: 80~140VAC×(1±3%)

 

 

Battery

Input

Nominal Voltage24V36V48V72V72V96V192V192V192V/240V
 Battery Capacity & Quantity

12V/9AH

x 2pcs

External

12V/9AH

x 4pcs

External

12V/9AH

x 6pcs

External12V/9AH x 16pcsExternal

12V/9AH

x16/20pcs

External
 Backup Time

Half loaded≥8minutes,

Full loaded ≥3minutes(standard)

Half loaded≥6minutes,

Full loaded ≥3minutes(standard)

 Battery charger timeCharger to 90% battery capacity in 5 hours(standard) Dependent on the capacity of external batteries (long backup time)

 

 

 

AC Output

Output systemSingle phase (L/N+PE)
 

Inverter Mode

Output voltage

HV:208/220/230/240Vac±2%

LV:100/110/120/127Vac±2%

 Waveform

Sine Wave

THD<3% (linear load)

THD<7% (nonlinear load)

Sine Wave

THD<2% (linear load)

THD<5% (nonlinear load)

 Output frequency

50/60±4Hz (Sync mode)

50/60Hz±1% (Fix Freq. mode)

 

 

 

 

 

Hot Products

1KVA 3KVA Single Phase Online UPS Network Rack Mount Battery Backup Rack Mount UPS High Frequency ...
100VAC 240VAC 1000va Rack Mount UPS Single Phase Battery Backup #detail_decorate_root .magic-0...
High Frequency 230VAC 6KVA Rack Mountable UPS With Snmp Card Rack Mount UPS High Frequency Online ...
19 Inch Small Rack Mount UPS 1kva 2kva 3kva 6kva High Frequency Online Pure Sine Wave UPS Zero ...
Rack UPS Power Supply Rack Mount 1KVA ~ 10KVA Single Phase UPS Built-in Battery For Home True double...
19 Inch Small Rack Mount UPS 1kva 2kva 3kva 6kva High Frequency Online Pure Sine Wave UPS Zero ...