Dynamic Corporation Limited |
Verified Suppliers
|
|
Dcl 110V Electric Control Actuator with Valve, Quarter Turn
Actuator with handwheel
Feature:
Permanently Lubricated Heavy Duty Aluminum Alloy
Manual Override (except on the M25)
Adjustable Travel Stops
NEMA 4, 4X Weatherproof Enclosure
ISO 5211 Direct Mount Capabilities
1/2" NPT Conduit Entries (2),G1/2 water-proof cable
Thermal Overload Protection
80% Duty Cycle
4 Limit Switches
Standard 110V AC Single Phase Options
Type DCL-05 Series actuator Performance Parameters:
Motor power :24VDC 24VAC 110VAC 220VAC 380VAC
Standard time/Torque:25s/50Nm
Optional Time/Torque:4s/20Nm 10s/30Nm,60s/50Nm
Turning Angle: 0~360 degree
Total weight:2.0kg
Protection Class:IP67
Installation angle: 360degree at any angle
Electric interface:Two G1/2 water-proof Cable connectors, one for
power line and one for signal line.
Optional Fuction : Heater for eliminating mositure
Square: 9*9 11*11 14*14
Flange: F03 F05 F07
Description
DCL common series electric actuator are typically used to drive quarter turn butterfly valves, ball valves, dampers and swinging arms. On receipt of a continuous power signal, the motor runs one direction and via an all metal gear box with last stage worm gear train rotates the output drive 90°. The motor is automatically stopped by internal cams striking limit switches. On receipt of a reversing continuous signal, the motor turns in the opposite direction reversing the output drive position.
Over torque protector is optional only if accurate output torque is needed. PTC electronic heating component is also used as thermostatically controlled anti-condensation heater that will protect actuator against damage from condensation.
Specification:
Actuator Type | Standard Time/Torque | Optional Time/Torque | Turning Angle(Max.range) | Total Weight | Power Supply | Selected Control Circuit |
DCL-02 | 15S/18Nm | 7S/9Nm 60S/18Nm | 0~90°Adjustable | 1.2Kg | DC24V/AC24V AV110V/AC220V | Types of A/B/E/G |
DCL-05 | 20S/50Nm | 4S/20Nm 10S/30Nm 60S/50Nm | 0~360°Adjustable | 2.5Kg | DC24V/AC24V AV110V/AC220V/AC380V | Types of A/B/C/D/E/F/G/H |
DCL-10 | 30S/100Nm | 15S/50Nm 60S/100Nm | 0~360°Adjustable | 4.5Kg | DC24V/AC24V AV110V/AC220V/AC380V | Types of A/B/C/D/E/F/G/H |
DCL-20 | 30S/200Nm | 15S/100Nm 60S/200Nm | 0~90°Adjustable | 9Kg | DC24V/AC24V AV110V/AC220V/AC380V | Types of A/B/C/D/E/F/G/H |
DCL-40 | 30S/400Nm | 15S/200Nm 60S/400Nm | 9.5Kg | |||
DCL-60 | 45S/600Nm | 10Kg | ||||
DCL-100 | 30S/1000Nm | 15S/500Nm | 0~90°Adjustable | 19Kg | AV110V/AC220V/AC380V | Types of A/B/C/D/E/F/H |
DCL-160 | 48S/1600Nm | 19.5Kg | ||||
DCL-250 | 75S/2500Nm | 20Kg | ||||
Performance Parameters List of Adjusting type(Type E) | ||||||
DCL-MZZ | 18Nm | 3r | 1.2Kg | DC24V | Type MZZ | |
DCL-10GE | 30S/0~100Nm | 15S/0~100Nm | 0~90°Adjustable | 4.5Kg | DC24V±10% | Type GE |
DCL-40GE | 30S/100~600Nm | 15S/100~400Nm | 9.5Kg |
Actuator Type | Butterfly Valve(≤PN1.0MPa) | Ball Valve(≤PN1.6MPa) | Vent Valve(≤PN0.1MPa) |
DCL-02 | ≤DN40 | ≤DN32 | |
DCL-05 | DN50~65 | DN40 | DN50~80 |
DCL-10 | DN80~100 | DN50~65 | DN100~200 |
DCL-20 | DN125~150 | DN80~100 | DN250~300 |
DCL-40 | DN200 | DN125 | DN350~450 |
DCL-60 | DN250 | DN150 | DN500~600 |
DCL-100 | DN300 | DN200 | DN700~800 |
DCL-160 | DN350~400 | DN250 | DN900 |
DCL-250 | DN450~600 | DN300~350 | DN1000~1200 |