Home Companies Suzhou Cherish Gas Technology Co.,Ltd.

Reliable Stable VPSA Oxygen Concentrator Long Service Life Low Failure Rate

Suzhou Cherish Gas Technology Co.,Ltd.

Contact Us

[China] country

Trade Verify

Address: No. 78 Tongxin Road, Tongan Town, High-tech Development Zone, Suzhou City, Jiangsu Province, China

Contact name:Jack Shi

Inquir Now

Suzhou Cherish Gas Technology Co.,Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Reliable Stable VPSA Oxygen Concentrator Long Service Life Low Failure Rate

Country/Region china
City & Province suzhou jiangsu
Categories Air Conditioners
InquireNow

Product Details

Reliable And Stable VPSA Oxygen Concentrator With Long Service Life And Low Failure Rate

 

Product nameVPSA Oxygen Generator
Oxygen delivery≤270Nm3/hr
Purity93%±3
Pressure0.2~0.3 Mpa
Atmospheric dew point≤-50℃

 

Working Principle Description:

Compression Stage:

Ambient air generated externally is compressed using an air compressor to increase its pressure and concentration.

During compression, the volume of air decreases, resulting in increased concentrations of oxygen and nitrogen.

 

Inlet Pretreatment Stage:

The compressed air undergoes pretreatment to remove moisture, oil contaminants, and impurities before entering the VPSA system.

Pretreatment steps typically involve cooling, filtration, and drying to enhance the quality and purity of the air.

 

Adsorption Stage:

The pre-treated compressed air enters the adsorption beds.

The adsorption beds are filled with adsorbent materials such as molecular sieves or zeolites.

In the adsorption beds, nitrogen molecules are selectively adsorbed by the adsorbent material, while oxygen passes through and is collected.

During the adsorption process, the pressure inside the beds gradually increases until it reaches a state of saturated adsorption.

Regeneration Stage:

When the adsorption beds reach a state of saturated adsorption, regeneration is required to release the adsorbed nitrogen.

The regeneration process typically involves two steps: pressure equalization and desorption.

Pressure Equalization: The pressure in the adsorption beds is equalized with the system pressure to prepare for desorption.

 

Desorption: The pressure in the adsorption beds is reduced, for example, by connecting a vacuum pump, allowing the nitrogen to desorb from the adsorbent material.

 

Bed Switching Stage:

Once one adsorption bed completes regeneration, the system switches to the other bed for the adsorption stage, while the previous bed undergoes regeneration.

The cyclic switching of the beds ensures continuous oxygen production.

 

By repeating these stages in a cycle, the VPSA system continuously extracts high-purity oxygen from the air to meet various oxygen requirements. A control system monitors and adjusts parameters throughout the stages to ensure the stability and efficiency of the oxygen production process.

 

Product Advantages:

Robust Construction: The VPSA oxygen generator is built with high-quality materials and components that are designed to withstand the rigors of continuous operation. Robust construction ensures durability and minimizes the risk of structural damage or component failure.

 

Advanced Monitoring Systems: VPSA oxygen generators are equipped with advanced monitoring systems that continuously track key operational parameters, such as pressure, temperature, and flow rates. Real-time monitoring enables early detection of any deviations or abnormalities, allowing prompt corrective actions to prevent potential failures.

 

Comprehensive Maintenance Plans: VPSA oxygen generators often come with comprehensive maintenance plans that include regular inspections, cleaning, and servicing of critical components. Scheduled maintenance helps identify and address potential issues before they escalate into major failures, ensuring long-term reliability.

 

Redundancy and Backup Systems: To enhance reliability, VPSA oxygen generators may incorporate redundancy and backup systems. For example, multiple adsorption units or adsorbent beds can be included, allowing uninterrupted oxygen production even if one unit or bed requires maintenance or experiences a temporary malfunction.

 

Quality Control and Testing: VPSA oxygen generators undergo rigorous quality control procedures during the manufacturing process. Each unit is thoroughly tested to ensure proper functioning, performance, and adherence to safety standards. This meticulous quality control process helps minimize the occurrence of defects or malfunctions that could lead to failures.

 

Continuous Improvement and Upgrades: Manufacturers of VPSA oxygen generators invest in continuous improvement initiatives to enhance product reliability and performance. They incorporate user feedback, conduct research and development, and implement technological advancements to reduce failure rates and extend the lifespan of the equipment.

 

Experienced Technical Support: VPSA oxygen generator manufacturers often provide experienced technical support to assist users in troubleshooting, maintenance, and addressing any operational issues. This ensures prompt and effective resolution of problems, minimizing downtime and maximizing the reliability of the equipment.

 

In summary, a reliable and stable VPSA oxygen generator exhibits a long lifespan and a low failure rate. Its robust construction, advanced monitoring systems, comprehensive maintenance plans, redundancy measures, quality control procedures, continuous improvement efforts, and access to technical support contribute to its overall reliability.

 

Technical parameters:

● Oxygen delivery: ≤270Nm3/hr;

● Purity: 93%±3

● Pressure: 0.2~0.3 Mpa

● Atmospheric dew point: ≤-50℃

 

Product picture:

Hot Products

PSA Oxygen Generators That Reduce Footprint And Storage Space, Flexibly Applied In Hospitals, ...
PSA Oxygen Generators That Reduce Footprint And Storage Space, Flexibly Applied In Hospitals, ...
PSA Oxygen Generator With Strong Stability And Automated Control, Real-Time Monitoring To Improve ...
Reliable And Stable PSA Oxygen Generator With Low Noise Pollution, Suitable For Special Places Such ...
PSA Oxygen Generators Operate Stably With Strong Adaptability, Adapting To Different Temperatures, ...
PSA Oxygen Generator With Adjustable Purity Can Adjust The Purity Of The Extracted Oxygen As Needed ...