Customization In Row Air Cooled Unit For Laboratory

Country/Region china
City & Province hefei anhui
InquireNow

Product Details

Customization In Row Air Cooled Unit For Laboratory
 
 

Product Introduction                         

The In row air condition is a device placed between the columns of the server cabinet, and the heat source directly dissipates heat. The precision air conditioner in the inter-row room is a type of air conditioner in the room. It is a horizontal air supply unit. Due to the increasing heat dissipation of the server or communication equipment used in the data center, the traditional air conditioning refrigeration method can no longer meet the requirements of the equipment for temperature and humidity. In order to achieve efficient cooling of the equipment and avoid local overheating phenomenon, cold air must be organized into the interior of the equipment for heat dissipation. At this time, the cold and hot channel isolation or closure of the cold and hot channel can effectively control the short circuit of the cold air flow and hot air flow, and reduce the cooling effect.

 

Advantage                                          

 

  • The unit is specially designed for the inter-column channel, pure sheet metal production, solid and reliable.
  • The frame is made of 2.0mm thick cold rolled plate, coated with black plastic powder, lined with sound absorption and heat insulation material, with good tightness.
  • The shell is made of 1.5mm thick cold rolled sheet, coated with black plastic powder, lined with heat insulation and sound absorption material, good tightness, can prevent air leakage to ensure heat exchange effect, and effectively reduce noise.
  • The unit is provided with a back door with hinges and door locks, and 4 side doors with door locks, easy to assemble and disassemble, convenient to provide maintenance services.
  • The door lock must be opened with a special key for convenient management.

 

 

 

Technical Features                              

High Efficiency-DC Inverter Compressor of DX System
Dynamic cooling to adapt to the rapidly changing load of the computer room; Save energy and improve energy efficiency under low load; It can greatly reduce the number of compressor starts and stops, and improve system reliability
 
High Efficiency-Electronic Expansion Valve
Smoothly adjust the throttle opening, ma
tched with variable capacity compressor To achieve energy saving;
Wide adjustment range, reduce superheat and improve energy efficiency ratio Reduce cooling capacity and load;
Fast response speed, realizing precise refrigeration;
 
High Efficiency-Backward Centrifugal EC Fan
Compared with ordinary standard AC motors, the electronically commutated synchronous EC motors can save energy by 30%;
Automatically adjust the fan speed according to the cooling demand or wind pressure, and provide the air volume on demand;
Fan N+1 redundant configuration, any fan failure can still ensure full air volume operation;
 
Soft start function, low starting current
Easy maintenance design

 

 

Factory Details                                         

Precision Air Conditioning Unit In Row For Modular Data Center 6
 
Delivery & Packing                                              

 
 

Cases                                                                

 

Precision Air Conditioning Unit In Row For Modular Data Center 5

 

 

 

 

 

 

 
 
 
 

Hot Products

12.5kW Precision Air Conditioning For Small And Medium-Sized Data Centers Black Color Products ...
Single Phase 6.4kW Precision Air Conditioning DX Units For Small Data Center And It Equipment Room ...
17.5kW PACU Designed With A Large Air Volume And A Small Enthalpy For IT Equipment Room Products ...
Constant Temperature and Humidity Precision air conditionning 7.5KW three-phase 380V 50Hz Products ...
Quiet And Efficient Indoor Precision Air Conditioning Unit 17.5kW 20.2kW For Base Station Products ...
Precision Control With The Smallest Footprint Feasible 50kW CyberMasterSeries Of DX Unit Introductio...