Cabinet Micro Data Center With Rack Mounted Precision Air Conditioner

Country/Region china
City & Province hefei anhui
Categories Toilet Tissue
InquireNow

Product Details

Cabinet Data Center Micro Data Center With Rack Mounted Precision Air Conditioner

 

Product Introduction                                                           

Coolnet Cabinet Data Center is an integrated cabinet which contains cooling system, power system, monitoring system and rack system, etc.. There are more and more micro data centers, and it has been facing the dilemma that it is difficult to unify the planning, construction and operation management. The integrated cabinet deeply integrates data center infrastructure products, including multiple subsystems such as UPS, power distribution, refrigeration, cabinets, and fire protection, and implements overall management of the entire system through the monitoring system.

 

Advantages                                                                          

1. More precise. In-depth integration of UPS integrated cabinet products, and factory pre-verification tests are more standardized, safe and reliable than on-site construction; the fully sealed design eliminates the harm of external air dust and corrosive gases to IT equipment; the dynamic environment monitoring system is fully Monitor infrastructure in all directions, alert abnormal conditions in time, and be safe and secure.


2. More time-saving. The productized design allows the IC series cabinet-type smart data center to complete the installation and delivery within one day on site, which is more than 2 times faster than the traditional construction mode.


3. Lower space. The Coolent integrated cabinet data center design saves more than 40% of the floor space compared to the traditional computer room and saves supporting investment: fully enclosed design, can be installed in various environments (computer room, utility room, aisle, etc.), without the need for special investment in computer room construction and supporting facilities Save construction time.

 

Feature                                                                                    

 

Cooling System

 

Adopting international advanced components and self-developed precision control system, it has been successfully used in a large number of data centers and integrated cabinets. The cooling capacity is 7KW-12KW, and it can operate for 7*24*365 hours in order to provide a stable working environment for the equipment.

 

UPS System

 

As a public power grid, the mains system is connected to thousands of various loads, some of which are larger inductive, capacitive, switching power supplies and other loads, not only obtain power from the grid, but also have an impact on the grid in turn Deteriorating the quality of the grid. The UPS integrated in the cabinet can provide a stable power supply, which is enough to ensure the stable operation of the server.

 

Rack System

 

Using visual monitoring and display, the main interface is the overall information display, and the detailed information of each subsystem is also viewed, making it easier for managers to obtain equipment information.

 

 

Technical Parameter                                                                

 

ModelEC08EC12EC20ERx
Power3KVA3-6KVA6-30KVA
Number of cabinets0.8m high cabinet, available space 8U1.2m high cabinet, available space 16UStandard 42U cabinet, free space 30U2-10 standard 42U glass door cabinets
Enclosed cabinetGlass door, IP5X, full cold and hot channel sealing
Power supply220VAC, 3KVA UPS, power backup customized as required, Class C lightning protection220VAC, 3-6KVA UPS, customized standby power, C-level lightning protection220V/380VAC, 6-30KVA UPS, power backup customized as required, Class C lightning protection
RefrigerationUnique air duct design, without air conditioner and outdoor unitRefrigerating capacity 3.5-6.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation;Refrigerating capacity 3.5-10.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation;
Monitor1U rack type monitoring host, monitoring temperature and humidity, door magnet, smoke sensor, electricity, etc., without display1U rack type monitoring host/10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring

 

Factory View                                                                                 

 

Case                                                                                     

 

 

 

 

 

 

 

 

 

Hot Products

12.5kW Precision Air Conditioning For Small And Medium-Sized Data Centers Black Color Products ...
Single Phase 6.4kW Precision Air Conditioning DX Units For Small Data Center And It Equipment Room ...
17.5kW PACU Designed With A Large Air Volume And A Small Enthalpy For IT Equipment Room Products ...
Constant Temperature and Humidity Precision air conditionning 7.5KW three-phase 380V 50Hz Products ...
Quiet And Efficient Indoor Precision Air Conditioning Unit 17.5kW 20.2kW For Base Station Products ...
Precision Control With The Smallest Footprint Feasible 50kW CyberMasterSeries Of DX Unit Introductio...