Customizable Smart Power Distribution unit

Country/Region china
City & Province hefei anhui
Categories Other Chargers
InquireNow

Product Details

Customizable Smart Power Distribution unit

 

Product introduction                                 

PDU (Protocol Data Unit) refers to the data unit transmitted between peer-to-peer levels. The common PDU in the field of computer room and communication hardware refers to the power socket of the cabinet. It is the English "Power Distribution Unit" or "DESIGNTED POWER DISTRIBUTION UNIT FOR". Abbreviation for "CABINET". That is, the power distribution unit, through the use of industry-standard PDU products, can improve the power security of network products and meet the power input requirements of important equipment.

 

With the development of computer network technology, the demand for key equipment such as servers, switches, and various electronic equipment is also increasing. The business undertaken by PDUs is becoming more and more critical, and the requirements for the environment where the equipment is located (such as computer rooms, cabinets, etc.) are also higher. , all facilities involved in the operation of critical equipment must have high reliability and availability. For the power outlet, it is the last point of power consumption for all devices. If it is not stable enough and lacks sufficient protection functions, it may lead to the destruction of expensive equipment or even the collapse of the entire system. Therefore, the safety and stability of power sockets is one of the powerful guarantees for the value of equipment and business systems.

 

Main Functions                                        

 

1. Multiple circuit protection functions

  • Surge protection: maximum impact current: 20KA or higher; limit voltage: ≤500V or lower; professional testing by Beijing Lightning Protection Test Center, can be used as equipment-side fine surge protection alarm protection: LED digital current display and Full current monitoring with alarm function
  • Filter protection: with fine filter protection, output ultra-stable pure power
  • Overload protection: Provides two-pole overload protection, which can effectively prevent problems caused by overload.
  • Anti-misoperation: PDU main control switch ON/OFF with protective barrier to prevent accidental shutdown, and provides optional dual-circuit

 

2. Interface compatibility

  • The standard power socket hole module of various countries in the world can meet the different needs of customers in many countries.
  • It can realize dual input, IEC socket input, product front panel input, product rear input, product end input and other forms.
  • National standard, British standard, German standard, American standard and Indian standard with various specifications.
  • Plugs of various specifications such as 10A, 16A and industrial couplers are available.

 

Parameter                                               

 

PDU

 

Parameters

 

 

input

Input typeAC single phase, AC three phase,-48VDC,240VDC,336VDC
Input mode

Transparent open type junction box,power cord, cable,

industrial connector, socket etc.

Input voltage range100-277VAC/312VAC-418VAC/11VDC-240VDC/-43VDC- -56VDC
AC input frequency50/60Hz
total load currentMAX 63A

 

 

Output

Storage temperature-40 - +70
Relative humidity5-95% (No condensation)
Atmospheric pressure70kPa - 106kPa
Working altitudeNo more than 4000M

 

 

Environmental

Working temperature-10 - +75
Storage temperature-40 - +80
Relative humidity5-95% (No condensation)
Working altitudeNo more than 4000M
IP ratingIP20
Protectioninput protection moduleCircuit breaker, lightning protection, leakage protector, temperature insepction module (optional)
Output protection moduleCircuit breaker, fuse box, fuse(optional)

 

Installation method                                 
250VAC PDU Unit For Computer Room Normal Operation 3

Certification                                           
250VAC PDU Unit For Computer Room Normal Operation 4

Case                                             
250VAC PDU Unit For Computer Room Normal Operation 5

Factory                                         
250VAC PDU Unit For Computer Room Normal Operation 6

 

 

 

 

Hot Products

12.5kW Precision Air Conditioning For Small And Medium-Sized Data Centers Black Color Products ...
Single Phase 6.4kW Precision Air Conditioning DX Units For Small Data Center And It Equipment Room ...
17.5kW PACU Designed With A Large Air Volume And A Small Enthalpy For IT Equipment Room Products ...
Constant Temperature and Humidity Precision air conditionning 7.5KW three-phase 380V 50Hz Products ...
Quiet And Efficient Indoor Precision Air Conditioning Unit 17.5kW 20.2kW For Base Station Products ...
Precision Control With The Smallest Footprint Feasible 50kW CyberMasterSeries Of DX Unit Introductio...