Telecom Sites Rack Data Center With DC Inverter Rack Mounted Precise AC Units

Country/Region china
City & Province hefei anhui
InquireNow

Product Details

Rack Data Center For Telecom Sites With DC Inverter Rack Mounted Precise AC Units
 


Product Introduction                                          

What is an all-in-one cabinet? The integrated cabinet is an in-depth integration of data center infrastructure products, including UPS, power distribution, refrigeration, fire protection and other subsystems, through the monitoring system to complete the overall management of all systems, simplifying the planning and construction process. The reliable UPS power distribution system continuously escorts the IT equipment, and at the same time is equipped with a good cooling system to ensure the operating environment of the IT equipment, the deployment of the dynamic ring monitoring system, and the real-time monitoring of the operating status of the equipment. Coolnet all-in-one cabinets are popular among small and medium-sized enterprises due to their small footprint, long service life and low cost.

Feature                                                                    

Power Distribution System
 

  • 3-30KVA capacity optional
  • Rack mount
  • Backup power time customized (15-120m)
  • ATS dual input switch (optional)
  • Industrial-grade devices, built-in C-level lightning protection
  • Comprehensive monitoring, real-time power display

 

 

Advantages                                                                 

  • The reliable UPS power supply and distribution system continuously escorts IT equipment, and can also customize a highly reliable system architecture that meets the national standard A and B standards to meet the availability requirements of different users.
  • Equipped with emergency ventilation device, when the air conditioner fails, natural ventilation can be turned on to provide time for users to back up; it can also be linked with the fire fighting system to make fire extinguishing gas smoothly enter the cabinet.
  • High-efficiency and energy-saving: high-frequency UPS, the efficiency of the whole machine reaches 92%; cabinet-level refrigeration + fully enclosed hot and cold aisle refrigeration, which saves more than 30% energy than the traditional cooling method, and the PUE of the whole machine can be lower than 1.45.
  • Reserve an external emergency power supply interface, which can supply power to the internal equipment through the external power supply system when the power is off.
  • The box has the characteristics of dust-proof, sun-proof and rain-proof, and is fully adapted to the outdoor environment.

 

Technical Parameter                                                    

 

ModelEC08EC12EC20ERx
Power3KVA3-6KVA6-30KVA
Number of cabinets0.8m high cabinet, available space 8U1.2m high cabinet, available space 16UStandard 42U cabinet, free space 30U2-10 standard 42U glass door cabinets
Enclosed cabinetGlass door, IP5X, full cold and hot channel sealing
Power supply220VAC, 3KVA UPS, power backup customized as required, Class C lightning protection220VAC, 3-6KVA UPS, customized standby power, C-level lightning protection220V/380VAC, 6-30KVA UPS, power backup customized as required, Class C lightning protection
RefrigerationUnique air duct design, without air conditioner and outdoor unitRefrigerating capacity 3.5-6.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation;Refrigerating capacity 3.5-10.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation;
Monitor1U rack type monitoring host, monitoring temperature and humidity, door magnet, smoke sensor, electricity, etc., without display1U rack type monitoring host/10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring

 

Certification                                                                     

 

 

Packing&Delivery                                                             

 

Case                                                                             

 

 

 

 

 

Hot Products

Precision Air Handling Units For Server Rooms With EC Fan And Large Airflow Product Introduction ...
Coolnet Precision Air Handling Units For Precise Work Places With EC Fans Product Introduction ...
Hermetic Compressor Computer Room Air Cooling Unit For Large Switch Stations Products Introduction ...
Brand New 70-80Kw Coolnet Precision Air Conditioning Units For Mobile Stations Product Introduction ...
80-100Kw Large Cooling Capacity Precision Air Conditioners For Communication Base Stations Products ...
Electronic Centrifugal Fan 80-90kw Precision Air Conditioning Units For Clean Rooms Product ...