Server Room Cooling Units For Precise Experiment Rooms

Country/Region china
City & Province hefei anhui
Categories Toilet Tissue
InquireNow

Product Details

Server Room Cooling Units For Precise Experiment Rooms To Provide Fixed Temperature

 

 

Product Introduction                                          

Cool-smart series is a series of unit air conditioners developed for small and medium-sized communication data centers. It can control the temperature and humidity of the computer room, and has a variety of cooling capacity models, which can be flexibly selected according to the actual situation of the client room. Each air-cooled Cool-smart series system consists of an indoor unit and an outdoor unit.

 

Features                                                                          

 

High reliability

  • Provide Constant temperature & humidity, cleanness precision environment to ensure the main equipment in good running condition
  • 24-hour running design guarantee main equipment operation safety
  • All units had passed a severe running test before delivery, which can ensure units’ high reliability.

 

High energy efficiency

  • SHR (sensible heat ratio) is larger than 90%.
  • Compressor EER is larger than 3.1
  • Optimal and high efficiency compressor and fan in CRAC industry.
  • Maximum evaporator in CRAC industry ensures the highest heat exchange efficiency.
  • Optimal CFD air duct design: minimum air duct resistance & minimumfan power
  • Inverter IDU: high efficiency & long working life
  • Advanced control logic: avoid competitive running and output cooling capacity according to actual cooling capacity demand.

 

Easy maintenance

  • Front panel maintenance: all maintenance operation can be finished
  • from the front panel
  • Air filter with metal frame: cleanable repeatedly with low maintenance cost.
  • Auto-clean function: lower maintenance work
  • Metal frame with marine protection grade: durable and less maintenance work.
  • All metal fans of ODU & IDU: durable & high end
  • Remote control: convenient management & maintenance

 

Scope of Application                                                    

 

  • Small-Medium size computer room
  • Communication base
  • Rail road, Army, Broadcast base
  • Power room, substation
  • Monitoring room, Power distribution room, Battery room
  • High precision lab, Test room, Inspection room, Measuring room
  • Industrial control room, Precision workshop
  • Archives,Store room, Museum, Wine cellar

 

Product Specification                                            

ModelM04M06M08M13M16M20
Power Supply220V1Ph-50Hz380V3Ph-50Hz
Air dischargeUp Front/Down
Technical Data Sheet
AC FanTotal cooling capacity-KW4.26.47.512.516.820.2
Sensible cooling capacity-KW3.95.86.911.315.318.3
Unit FLA-A(heating, humidifying type)20.025.016.822.023.528.6
Compressor Quantity1
Fan Quantity1
Air Volume-m3/h160019002300360051006500
Heater Capacity-KW3.03.06.06.06.06.0
Humidification-kg/h333366
Power of humidifier-KW2.32.32.32.34.54.5
Outdoor Condenser
ModelSCA020SCA020SCA030SCA030SCA050SCA050
Standard unit operating temperature range-℃-15-45℃
Low Temperature Components Operating Temperature Range-℃-40-45℃

 

Certificates                                       

Factory Details                                               

 

Delivery & Packing                                          

 

Case                                                    

 

 

 

 

Hot Products

Large Air Volume And Cooling Capacity Precise Air Conditioners For Industrial Test Room Product ...
Precision Air Conditioning System For IT Data Center With Hermetic Compressor Product Introduction ...
Precise Large Server Room Air-Conditioning Units For High-Tech Industrial Workplaces Product ...
25-35KW High Utilized Air Conditioning Units For Precise Workshops With EC Fan Product Introduction ...
Direct Driven Fan Precision Air Conditioning System For Industrial Workplaces Product Introduction ...
Computer Room Air Handler Precision Air Conditioner With Hermetic Compressor Product Introduction ...