Telecom Sites Electrical Cabinet Air Conditioner 600W Air Conditioner

Country/Region china
City & Province hefei anhui
Categories Toilet Tissue
InquireNow

Product Details

Telecom Sites Electrical Cabinet Air Conditioner ​600W Air Conditioner

 

 

Product Introduction                                                           

Coolent is a professional thermal control solutions provider for outdoor cabinets. Coolnet has accumulated rich technological experience and lots of application in this field. The EA series is the result of Coolent technology applied in AC and DC dual powered outdoor cabinet.The cooling range is 1000~3000W, heat exchanger range is 80w/k~120w/k.

Coolnet also has many other series products for outdoor cabinet and base station usage. Such as AC air conditioner, DC air conditioner and heat exchanger.

 
 
 
Benefits                                                                                  

 

Features                                                                                   

● The product is durable and anti-corrosion, with a service life of 15 years.

● Flexible and diverse product configuration

● Integrated temperature control system (fan, heat exchanger or air conditioning)

● High protection grade, protection grade up to IP55.

●EMC/RFI protection.

● Noise reduction processing.

● Using electrophoresis and special outdoor powder to enhance outdoor corrosion resistance and UV resistance.

● The main equipment, temperature and voltage equipment and wiring module in the cabinet implement subdivision design, which is convenient for future classification maintenance.

● Anti-theft design, high anti-damage coefficient.

● Earthquake resistance.

● Integrated electrical wiring and AC/DC distribution system.

 

Advantages                                                                            

Compared with traditional cabinets and equipment rooms, the outdoor integrated cabinet occupies a small area, shorens the construction period, reduces the single-path faults between functional modules, and greatly improves the compatibility between systems. In addition, the outdoor integrated cabinet maximizes the space utilization of the user's equipment room and provides users with a small intelligent equipment room system that is more consistent, integrated, manageability, and expansibility.

The outdoor integrated cabinet is mainly used for wireless communication base stations, including the new generation 5G system, communication/network integrated service, access/transmission exchange station, emergency communication/transmission, etc. The hot dip zinc plate with thickness greater than 1.5mm is adopted, which is composed of the outer box, the inner metal parts and accessories assembly. The cabinet is divided into equipment room and battery room according to its functions. Compact structure, easy installation, excellent sealing performance.

 

Technical Specification                                                                         

 

Model EA-300
Power Supply( V,Hz) 1P 220,50
Dimension (mm)W286
H445
D175
Cooling Capacity 300W
Running Current 1.48A
Starting Current 6.5A
Power 287W
Refrigerant Type R134a
Noise Level 55dB
Cabinet Protection Rationinternal circuitIP34
external circuitIP33
Cabinet Temperature Limits 25℃~38℃(Factory Set 30℃)
Ambient Temperature Limits -5℃~43℃
Power Connection Triangle Power Plug( 2 Meters Length)
Weight 15Kg
Color RAL 7035(Light Gray)
Flow Rateinternal circuit70m3/h
external circuit150m3/h
Temperature Control Type Digital Display

Test condition: dry bulb temperature inside the cabinet 35 ℃, wet bulb temperature 26 ℃;

dry-bulb temperature outside the cabinets 35 ℃

 

Certification                                                                                            

 

Packing&Delivery                                                                      

 

 

 

 

 

 

Hot Products

Precision Air Conditioning Cooling System For Large Computer Rooms IDC Internet Data Center Product ...
Precision Laboratory Precision Air Conditioner And Constant Temperature And Humidity Air Conditioner ...
Precision Air Conditioner Designer Solution In Computer Room Product Introduction The computer room ...
Precision AC Air Conditioning For Telecom And Data Center Products Introduction Coolnet precision ...
Server Air Conditioner Cooling Machine For Telecommunications Network Product Introduction Sever air ...
Computer Room Air Handler For Telecom And Data Center Product Introduction Computer Room Air Handler ...