Home Companies Zhengzhou Great Electric Co.,Ltd.

Phase Angle Error CT PT Test Set

Zhengzhou Great Electric Co.,Ltd.
Active Member

Contact Us

[China] country

Address: No.1207-1, Building #1, the National University Sci-Tech Park of Henan Province, No.11 Changchun Road, Zhengzhou, Henan 450000

Contact name:Tony Han

Inquir Now

Zhengzhou Great Electric Co.,Ltd.

Phase Angle Error CT PT Test Set

Country/Region china
City & Province zhengzhou henan
InquireNow

Product Details

 

Digital Transformer Tester HEWE series CT PT Test Equipment Comparator

 

 

Technical Parameter

Accuracy class2
Current range5A, 1A
Voltage range100V,100/√3V
Percentage ErrorLess than 1.5%*FS
Basic Error
When testing CT PT error & impedance & admittance, the error will not beyond:

ΔX=±(X*2%+Y*2%+Dx)

ΔY=±(X*2%+Y*2%+Dy)

ΔX: basic error limit value of in-phase component

ΔY: basic error limit value of Quadrature Component

X: Indication absolute value of in-phase component

Y: Indication absolute value of Quadrature Component

Dx & Dy: Zero error and Quantizing Error

When testing CT & PT, Dx,Dy=1(or 2)%*(Error limit value of CT & PT

When testing Z & Y, Dx,Dy= 3 digits

 

Measure Range & Resolution

CT PT classTest RangeResolution
In-phase componentQuadrature ComponentIn-phase componentQuadrature Component
0.01±0.4000±13.7520.0001%0.001'
0.02
0.05
0.1±4.000±137.520.001%0.01'
0.2
0.5
1.0±40.00±999.90.01%0.1'
Impedance Measure Range & Resolution
RangeMeasure Range (Ω)Resolution
5A±1.0000.0001
1A±6.0000.0001
Admittance Measure Range & Resolution
RangeMeasure Range (mS)Resolution
100V±9.99990.0001
57.7V±9.99990.0001

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Features

 

1) LCD display

2) Test of ratio, ratio error, phase angle error, impedance, admittance

3) Test data values are all displayed

4) Used for testing of class 1 to 0.01 instrument transformer with rated current 5A and 1A, 

    rated voltage 100V, 100V√3V

5) Display ratio error & phase angle error of all test points under rated burden or lower limit

    burden 1%-120% Rated current or 20%-120% rated voltage

 

                                            Design for options

Hot Products

High Accuracy Class Three Phase Electric Meter Test Bench 1) Standard Meter accuracy: 0.05%, 0.02% ...
0.05 Class Three Phase Electric Meter Test Bench Technical Parameters Accuracy class 0.05, 0.1 ...
3 meters serial connection semi-automatic water meter test bench 1. Main technical index 1.1 ...
0.05 Class Three Phase Electric Meter Test Bench Major Application and Functions: 1) Touch screen ...
0.05 Class Three Phase Electric Meter Test Bench Major Application and Functions: 1) Touch screen ...
0.05 Class Three Phase Electric Meter Test Bench 1.1:LCD touch screen: After power on, then ...