Technical Parameter                                                                                                                                      

 

 Right angleEmbeddedInlinePlug
Design-pressure0.3~0.8MPa0.2~0.8MPa0.3~0.8MPa0.2~1.0MPa
Working-pressure0.3~0.6MPa0.2~0.6MPa0.3~0.6MPa0.2~0.6MPa
Ambient Temperature-25~60℃ Customized for lower or higher temperature
Relative Humidity≤85%
Working MediumClean Air
VoltageAC220V/DC24V/AC110V/AC24V Customized
Protection ClassIP65
Diaphragm LifeOver One Million Cycles
Cv/KvCall us for detail

 


 

Body : ADC12 die cast

Armature : 430 FR stainless steel

Diaphragm : Nitrile or Viton

Spring : 321 stainless steel

Fasteners : 302 stainless steel

 

Good quality membranes shall be selected and used for all the valves , with each part checked in each manufacturing procedure , and put into the assembly ling conforming to all the procedures . Every finished valve shall be taken the electriferous blowing test .

 


During installation and commissioning                                                                                                          

 

Failure phenomena 

 

1 . The valves cannot all be opened, but the leading part does act.

2 . Some valves do not work, but the others are normal.

3 . The valves cannot all be closed. There is leakage. There is no way to establish a gas dome.

4 . Some valves cannot be closed. There is leakage.

5 . A valve closing is slowly.

 

Possible Reason

 

1 . Check the gas dome pressure to see if it is too low.

2 . Check the valve coil connection and coil

3 ( 1 ) . Y-valve. Some valves for the same gas dome are leaking, thus causing leakage for all the valves.

3 ( 2 ) . Z-valve. The valve inlet and blowing muzzle are installed backwards.

4 . There is some dirt or debris on the membrane, ii is blocking the moving iron core.

5 . The membrane orifice is blocked.

 

Troubleshooting

 

1 . Check the leakage

2 . Replace the accessories

3 ( 1 ) . Check the leakage

3 ( 2 ) . Re-install

4 . Clean the membrane and check that the membrane is complete. Check the moving iron core and air lock.

5 . Dredge the membrane orifice

 

 


During use period                                                                                                                                         

 

Failure phenomena

 

1 . Some valves are leaking. The membrane cannot close tightly and the valve is always open a

little.

2 . Coil is hot and burned out.

3 . Voltage exists but the valve does not operate.

4 . Ambient temperature is below -20℃. The valve is leaking and cannot open.

 

Possible Reason

 

1 . There is some dirt or debris on the membrane, the leading part is damaged. Moving iron core is blocked.

2 . It has been turned on for too long.

3 . Membrane is damaged and the orifice is blocked.

4 . Ambient temperature is too low and here is frost in the valve.

 

Troubleshooting

 

1 . Clean the membrane and check that the membrane piece is complete. Check the moving iron core and the air lock. Replace the accessories if necessary.

2 . Check the working condition of the control system.

3 . Replace the accessories in time.

4 . Pay attention to insulation and maintaining proper temperatures.


Hot Products

AFC , BFC AirTAC Type Instrument Air Filter Regulator Lubricator High Performance The structrue is ...
AC901 -15 / 20 Series Filter Regulator + Lubricator G Thread 1 1 / 2 " , 2 " Port Size Specification ...
399 - 08 / 15 / 20 / 25 HERIO Series Instrument Air Filter Regulator Lubricator Why choose us 1: ...
AF2000 BF2000 Filter AirTAC Type Air Source Equipment Units AitTac Type FRL Units Air Compressor ...
GF200 GF300 Filter Air Source Equipment Units FRL Units Air Compressor Parts Sanmin All FRL units ...
AF2000 AF4000 Filter SMC Type Air Source Equipment Units SMC Type FRL Units Air Compressor Parts ...