Home Companies YIKANG AUTOMATION

Orion Stainless Steel Auto Drain Valve Refrigeration Facilities Filter AD - 5

YIKANG AUTOMATION

Contact Us

Trade Verify

Address: Liandong-U-Gu 17-2#, Shengyuan Road 1#, Jiangkou Street, Fenghua District, Ningbo City, Zhejiang Province, China

Phone: +86-

Contact name:Jaren

Inquir Now

YIKANG AUTOMATION

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Orion Stainless Steel Auto Drain Valve Refrigeration Facilities Filter AD - 5

City & Province ningbo zhejiang
Categories Air-Compressor Parts
InquireNow

Product Details

 

Orion Stainless Steel Auto Drain Valve Refrigeration Facilities Filter AD - 5

 

Ordering Code: AD-5

 

Specification

1. Note: The product is for industrial. Please attention to use.
2. For the proper operation of the product, please readthis carefully.

For security, be sure to comply with it.
Warning: if use it in a wrong way, may cause the user serious injury or death.
1. When clean, repair and check, please pumping out the compressed air in the pressure container. If there is residual air, the component will fly up, cause damage.
2. For installation, must according to this manual. Wrong installation will cause water leakage or air leakage.
3. Do not use other liquid, only the specified. Authorized liquid, is compressed air, Others may cause the product broken, like breakdown, leakage and etc.
4. Confirm the piping of drainage. Inappropriate piping, will cause leakage and get wet the facility.
5. When transfer and lend the products, please transmit the manual too. When sell or transfer the used products, in order to let the new user could use safely, please place the manual obviously.
6. No drain without water. Please close the handle of the inlet drainage device. Or, the valve core will be abnormal abrasion.
7. How to keep the product (Long time without use)
1). Dismantle the product after close the ball valve.
2). Drain out the water in drain-pipe. Get rid of the water in the drainage device. Observe from the bottom up, turn right, to drain out the water in the cup.
3). Keep away the garbage, dust and rainwater when keep the product.
Attention: If there's water residual in the drain-pipe, will cause the internal parts corrosion and damage, lead to breakdown.

Installation
1. Attention: As include plastic parts, cannot be installed at the environment which contains the following materials. Direct sunlight also should be avoid.

Chemicals TypeTypeMain productsGeneral use
Inorganic chemicalsAcidHydrochloric acid, Sulfuric acid, Fluorine acid, Phosphoric acid, Chromic acid, etcMetal pickling solution, Acidic degreaser, Leather coating liquid
Orgnic chemicalsAromatic hydrocarbonBenzene, Toluene, Xylene, Ethylbenzene, Styrene, etcPaint diluent
AlcoholMethyl alcohol, Medicinal alcohol, Cyclohexylethanol, Benzil alcohol, etcAntifreeze liquid
PhenolMethyl carbonate, Cresol, Naphthol, etcRaw material of Detergent and Phenol resin
KetoneAcetone, Methyl ethyl ketone, Cyclohexanone, Acetopheneone acid, etc 
Carbon acidFormic acid, Acetic acid, Butyric acid, Acrylic acid, Oxalic acid, Phthalate, etcChemical base of Dyeing agent and Aluminum coating treatment
Oxygen acid; AlkydGlycolic acid, Lactic acid,
Malic acid, Citric acid, etc
Food additive
AmineMethylamine, Dimethylamine,
Ethylamine, Aniline, Acetainilide, etc
Brake oil additives, Antistatic agent, Dye for plastic

2. Installation method.
Note: When install the drain-pipe, please be sure the status in outlet. Inappropriate piping, will cause leakage and get wet the facklity.
1). Pipe size
Inlet: Rc1/2    Outlet: Rc1/2
2). Installation and piping of drainage
When the drain-pipe outlet is downward, the product should be vertical installation. Check valve must be installed at the drain-pipe inlet.

Application method
1. Regulate the water displacement
The working clearance of drainage device will be different, according to the load and pressure. Cannot regulate the valve when the cup filed with water.
2. Note: Water comes from the compressed air is limited, so please do not set for empty working continuous. If not, will cause:
1). Valve core will be abnormal abrasion.
2). The insterstice will get shorter.
3). Abrasion will be speed up.
4). Spray continuously.
3. Note: If there is too much oil, will cause:
1). Output will be reduced.
2). The interstice will get longer. If there is too much oil, please regulate the oil regulator.

 

Product show:


 

Quality Standards :

 

The company for the products are brand new original products, no second-hand and refurbished products, or leave a compensable ten and return the full amount , but the buyer due to our purchase of model error is not responsible for returns, another of the company's sales of products enjoy one year from the date of shipment quality assurance , according to the original quality standards , during warranty with product problems , need confirmation testing by the manufacturer , the supplier to be solved , the demand side due to storage , use, poor maintenance caused by lower-quality product , and not raise objections 

 

Warranty:

 

All item Comes with Basic 3 Month Sellers Warranty, if item defective in 3 Month, We will offer replacement without extra Charger(including shipping fee)After we Receive the Defective item.
If item Defective after 3 Month, Buyers can still send it back, We will contact suppliers or Manufactory for Warranty. Buyers Might Need to pay the Shipping fee For resend the replaced item.

 

Competitive Advantage:

 

Our product features:Our Services Guarantee:
1) Competitive price1) Prompt respond (Reply with 24 hours)
2) Good quality2) Free Samples (Customer pay for the delivery cost)
3) Professional Packaging,3) Registration support.
4) Produce according to Customers’ instruction4) Photos/videos are available during production.
5) None delay shipment

5) Loading inspection, and send loading photos before shipment.

 

Hot Products

CU16NiI - 15S SMC Pneumatic Free Mount Cylinder Single Rod Double Acting Cylinder CU 16*15 Ordering ...
Free Mount cylinder CU20NiI - 20S Air Pneumatic Cylinder Single Rod CU 20*20 Ordering Code: CU20NiI...
SMC CU Series Pneumatic Air Cylinders CDU25NiI - 25S Pneumatic Actuator Cylinder Ordering Code: ...
SMC Free mount cylinder CU Series CDU32NiI - 15S CDU32-15 Single Acting Pneumatic Cylinder Ordering ...
MGPM12G - 30Nil SMC MGPM MGPL Double Acting Cylinder Pneumatic GMPM12-30Z Ordering Code: MGPM12G...
Compact Guide Pneumatic Air Cylinders MGPM16G - 30Nil Tri - Axial Cylinder GMPM 16*30 Ordering Code: ...