Solenoid Electromagnetic Induction Coil 400325-142 / 400325-242 / 400325117 / 400325217

City & Province ningbo zhejiang
Categories Paper Holders
InquireNow

Product Details

Solenoid Electromagnetic Induction Coil 400325-142 / 400325-242 / 400325117 / 400325217

 

 

 

Pulse valve is mainly used in environmental dust industries, such as electromagnetic or pneumatic control by the pilot valve can open and close the high-pressure gas source to generate pulse valve diaphragm valve in an instant , but also commonly known as electromagnetic pulse were pulsed valve or gas control valve .
 
what's it used for?
Electromagnetic pulse valve ( also called diaphragm valve ) is a pulse jet bag filter cleaning system air "switch", Control pulse controller output signal control, bag- by-row ( room ) injection cleaning , so dust resistance remain within the set range, in order to ensure the processing power and dust collection efficiency .
Z type pulse valve for the right angle , the angle between the import and export of 90 °, suitable for mounting the air bag and the link between the injection tube , air flow, providing cleaning gas pulses to meet the requirements .
Y type is submerged pulse valve ( also known as embedded valve ) , it is mounted directly on the air bag has better flow characteristics . Pressure loss decreased for the lower air pressure in the workplace .
 
How it works?
Before the diaphragm into the electromagnetic pulse valve , after two chambers , when connected to compressed air , compressed air through the orifice into the gas chamber , when the diaphragm chamber pressure will close the valve outlet , electromagnetic pulse valve is in the " off" state.
Electrical pulse controller of the pulse valve armature moves , the bleed hole to open the valve chamber , the gas chamber after rapid loss of pressure . After the diaphragm moves , blowing compressed air through the valve outlet . The pulse is "on" state.
Pulse jet control device signals disappear , electromagnetic pulse valve armature reset , after the chamber put stomatal closure , after the chamber pressure rises close to the diaphragm valve outlet , electromagnetic pulse valve is in the "off " state.
 
 
Pressure range(MPA)0.2~0.8
Ambient temperature(℃)-5~55
Use MediaCleaning Air
Relative Humidity﹤85%
VoltageDC24V AC220V

 

 

Hot Products

Pouch Packing mechine pneumatic solenoid valves poppet type Specification: 1. The model : CV-20 2. ...
CU16NiI - 15S SMC Pneumatic Free Mount Cylinder Single Rod Double Acting Cylinder CU 16*15 Ordering ...
Free Mount cylinder CU20NiI - 20S Air Pneumatic Cylinder Single Rod CU 20*20 Ordering Code: CU20NiI...
SMC CU Series Pneumatic Air Cylinders CDU25NiI - 25S Pneumatic Actuator Cylinder Ordering Code: ...
SMC Free mount cylinder CU Series CDU32NiI - 15S CDU32-15 Single Acting Pneumatic Cylinder Ordering ...
MGPM12G - 30Nil SMC MGPM MGPL Double Acting Cylinder Pneumatic GMPM12-30Z Ordering Code: MGPM12G...