Product Details

 

OMRON H3CR-A8-600 NEW 24-48 VAC 50/60HZ/ 12-48VDC TIMER

Lead time: 3-5 days

New with one year warranty

 

Time Ranges

 

Note: When the time setting knob is turned below "0" until the point where the time setting knob stops, the output will
operate instantaneously at all time range settings.
For details, refer to your OMRON website.

 

Standard (0.05-s to 300-h) Models

 

 

Time units (sec)×10 s (10 sec)min (min)×10 min (10 min)h (hrs)×10 h (10 hrs)
Full scale
setting
1.20.05 to 1.21.2 to 120.12 to 1.21.2 to 120.12 to 1.21.2 to 12
30.3 to 33 to 300.3 to 33 to 300.3 to 33 to 30
121.2 to 1212 to 1201.2 to 1212 to 1201.2 to 1212 to 120
303 to 3030 to 3003 to 3030 to 3003 to 3030 to 300

Characteristics

 

Accuracy of operating
time
±0.2% FS max. (±0.2%±10 ms max. in a range of 1.2 s or 3 s)
Setting error±5% FS ±50 ms *1
Reset timeMin. power-opening time: 0.1 s max.
Min. pulse width: 0.05 s (H3CR-A/-AS)
Reset voltage10% max. of rated supply voltage
Influence of voltage *2±0.2% FS max. (±0.2%±10 ms max. in a range of 1.2 s or 3 s)
Influence of temperature±1% FS max. (±1%±10 ms max. in a range of 1.2 s or 3 s)
Insulation resistance100 MΩ min. (at 500 VDC)
Dielectric strength2,000 VAC (1,000 VAC for H3CR-A[]S), 50/60 Hz for 1 min (between current-carrying
metal parts and exposed non-current-carrying metal parts)
2,000 VAC (1,000 VAC for H3CR-A[]S), 50/60 Hz for 1 min (between control output
terminals and operating circuit)
2,000 VAC, 50/60 Hz for 1 min (between contacts of different polarities)
1,000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other)
2,000 VAC, 50/60 Hz for 1 min (between input and control output terminals and
operation circuit) for H3CR-AP
Impulse withstand
voltage
5 kV (between power terminals) for 100 to 240 VAC/100 to 125 VDC, 1 kV for 24 to 48
VAC/12 to 48 VDC
5 kV (between current-carrying terminal and exposed non-current-carrying metal
parts) for 100 to 240 VAC/100 to 125 VDC, 1.5 kV for 24 to 48 VAC/12 to 48 VDC and
24 to 48 VAC/VDC
Noise immunity±1.5 kV (between power terminals) and ±600 V (between no-voltage input terminals),
square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)
Static immunityMalfunction: 8 kV
Destruction: 15 kV
Vibration resistanceDestruction: 10 to 55 Hz with 0.75-mm single amplitude each in 3 directions for 2 hours
each
Malfunction: 10 to 55 Hz with 0.5-mm single amplitude each in 3 directions for 10
minutes each
Shock resistanceDestruction: 1,000 m/s2 3 times each in 6 directions
Malfunction: 100 m/s2 3 times each in 6 directions
Ambient temperatureOperating: -10°C to 55°C (with no icing)
Storage: -25°C to 65°C (with no icing)
Ambient humidityOperating: 35% to 85%
Life expectancy *4Mechanical: 20,000,000 operations min. (under no load at 1,800 operations/h)
Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 1,800
operations/h) *3
EMC(EMI) EN61812-1
Emission Enclosure: EN55011 Group 1 class A
Emission AC Mains: EN55011 Group 1 class A
(EMS) EN61812-1
Immunity ESD: IEC61000-4-2
Immunity RF-interference: IEC61000-4-3
Immunity Burst: IEC61000-4-4
Immunity Surge: IEC61000-4-5
Immunity Conducted Disturbance: IEC61000-4-6
Immunity Voltage Dip/Interruption: IEC61000-4-11
Case colorLight gray (Munsell 5Y7/1)
Degree of protectionIP40 (panel surface)
WeightApprox. 90 g

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


Ironman Technology Co.,LTD

 

About us:

We specializes in automation parts and industrial controls, PLCS,DCS,Module/Board,Power supply,Controller, etc.We maintains an inventory of new and obsolete parts utilized in all areas of the manufacturing and industrial sectors.


Featured Brand:
● HONEYWELL ● AB ● OMRON ●SIEMENS ●SCHNEIDER

● ROSEMOUNT● ABB ● NOTIFIER ●MTL ● GE   ●And many more !


 

 

 

 


 

We have good price on AB PLC,Omron PLC and Honeywell C200,C300,model number such like TC/TK/MC/CC/511/512/513/514 and some FC series goods,
If you have other enquiry,pls feel free to let me know.
 
 

Hot Products

FC-TSAI-1620m Honeywell Safety Analog Input Field Termination Assembly Ironman Technology Co.,LTD ...
Honeywell TC-PRS021 51404305-225 C200 Control Processor New Genuine Ironman Technology Co.,LTD About ...
1756 BA1 PLC Control Module Allen Bradley ControlLogix PLC Battery AB New In Box Ironman Technology ...
1756-PA75R/A Allen Bradley ControlLogix Redundant Power Supply PLC Ironman Technology Co.,LTD About ...
Ironman Technology Co.,LTD About us: We specializes in automation parts and industrial controls, ...
High Level Analog Input with HART (4) IOM 1. There are two models of High Level Analog Input such as...