0 ~ 100℃ ± 2000mV Ring Shaped Platinum ORP Electrode For Sewage Water

Country/Region china
City & Province suzhou
Categories Other Titanium
InquireNow

Product Details

 

0~100℃ ±2000mV Ring-Shaped Platinum ORP Electrode For Sewage Water

 

 

Oxidation-reduction potential, abbreviated as ORP (abbreviation of English Oxidation-Reduction Potential) or Eh, has been used for a long time as a comprehensive indicator of environmental conditions of media (including soil, natural water, culture medium, etc.). It characterizes the relative degree of oxidative or reductive properties of the medium.

 

The unit of the ORP sensor is mv. It consists of ORP composite electrode and mv meter. An ORP electrode is an electrode that can absorb or release electrons on the surface of its sensitive layer, which is an inert metal, usually made of platinum and gold.  The reference electrode is the same silver/silver chloride electrode as the pH electrode.

 

It is used for potentiometric measurement, and at the same time it cannot participate in the chemical reaction process, which means that it has to withstand chemical shocks. Therefore, only precious metals such as platinum, gold or silver can be used here. As a reference electrode, an Ag/AgCl reference system is used as in the pH value measurement.

 

Specification:

  Product Name
 
  ORP sensor
Model
ASR401-VYD05
ORP Range
±2000mV
Reference Electrode
Ag/AgCl
Electrolyte
Crystal
Detection Heads
Ring-shaped platinum
Working Pressure
0~4 Bar
Working TEMP
0~100℃
Shaft Material
PPS
Membrane
Porous Teflon membrane
 Thread Size

 1 inch NTP(both ends)

 

Dimension
D: 35mm L: 260 mm ( include cleaning cover)
Lead Wire
Standard 5m
Temperature Unit
Vacant/NTC10K (optional)
Application
Industrial sewage
 Cleaning

  A protective cover with its own cleaning interface(Optional)

 

 

Please click the catalog of ORP controller here:

Daruifuno Catalog.pdf

 

Brief introduction:

◆ ORP composite electrode, ring-shaped platinum detection head, the body is packaged in high-performance PPS plastic case

◆ Sturdy structure, with installation threads at the beginning and end, easy to install; 

◆ The electrode is divided into 2 basic models according to the temperature unit packaging method, which is convenient for users to measure the temperature of the liquid simultaneously; 

◆ The electrode is equipped with a protective cover with its own cleaning interface

◆ The reference adopts a large-area annular porous Teflon membrane, 

◆ The reference system is a double-salt bridge design, the reference electrode is Ag/AgCl, and the reference is filled with saturated

 

Aplication:

Water treatment monitoring

Drinking water,surface water,water quality analyze,ground water,ect.

 

Industrial process monitoring and dosing control

Chemical,petroleum,paper,food and medicine,PCB manufacturing,etc.

 

FAQ

1. Does ORP measurement require temperature compensation?

A: ORP measurement is not temperature controlled, so the ORP sensor does not require temperature compensation.

 

2. How do we choose the ORP electrode when the oxidation level is high?

A: In occasions where the oxidation level is high, that is, the ORP value is high, platinum electrodes are recommended, otherwise gold electrodes are recommended. ORP measurements usually use the above two inert materials as indicator electrodes.

 

3. What is the wire length of the ORP electrode?

A: The lead wire of this electrode is 5m by default, other lengths need to be customized, contact our customer service, the price will vary with the change of length.

 

4. What should ORP electrodes be used with?

A: ORP electrode cannot be used alone, it must be connected with PH/ORP controller. We have a matching controller with a suitable price, and you can choose.

 

5: Are you trading company or manufacturer ?

A: Yes, We are SENSOR manufacturer and exporter in china with 10+ years experience and with the factory authorized by SGS.committed to producing high accuracy, long-term stability, cost-efficient online, portable(single-parameter and multi-parameter), water analysis instruments


6: What's your quality control system?
A: All of our products will be fully pre-inspection by QC departments before shipping to you . We have the certification of ISO,CE .


7: What is your shipping method?
A: Small orders are delivered with DHL, FedEx, TNT, UPS , EMS. Large orders are recommended to ship by sea.


8: Do you provide samples ? 
A: Yes,we have materials in stock to help you to get the samples as soon as we can.


9: How long will you give me the reply? 
A: We can support you 24Hours online service via email, skype, what’sapp, facebook etc within 1 hour.

 

10: Do you offer the OEM service?

A: Yes, we can offer OEM service and design the logo marking for you. But the minimum quantity is 50pcs for the first order .

 

11: What is your delivery time?

A: It is in 6-8 working days since the payment confirmed . If quantity is more than 100pcs /order, it will need extra 3-5 working days .

 

 

12.  Any discount?
A : For bulk purchase or distribution agents, we will apply the best price for you,If we have any promotions, we will post in store and send you an email to inform you

 

Hot Products

RS485 Interface PH Controller -2~+16pH For Water Treatment Monitoring DUC2-PH-H-A is a self...
Digital pH Meter With cleaning control For Industrial Processing Control DUC2-PH-H-D is a self...
OTA Online PH Transmitter with two settable 0/4~20mA current outputs DUC2-PH-H-A pH transmitter is ...
Date Record RS485 Interface PH Water Analyzer For Water Quality Monitoring DUC2-PH-S-D pH controller...
5 Points Multi-Slope Calibration And Differential Signal Solution Ground Analog PH/ ORP Controller ...
Analog PH/ ORP Controller With Historical data records and RS485 For Sewage Or Drinking Water pH ...