100~240V 4-20mA RS485 Online pH controller with Automatic Dosing Control for water

 

The APX1-G2 pH/ORP controller from Dreifenol connects to a variety of conventional pH/T or ORP combination sensors. The APX series of industrial on-line pH/ORP controllers not only meet the continuous measurement and display function, but also achieve signal output and control functions. There are a variety of output configurations to choose from to meet the different needs of low cost and high performance.

 

Advantages of pH/ORP controller:

  • pH glass electrode measurement method
  • Two configurable SPST multifunction relays
  • With 2 high-precision 0/4-20mA current output
  • 3.2 inch LCD screen, rich content
  • 1 two-wire RS485 communication interface
  • Support solution grounding, which can eliminate part of the solution leakage interference
  • AC and DC power modes, both wide voltage
  • Housing material reinforced ABS, protection class IP66

 

pH ORP controller Parameters:

 

Product Name

PH ORP controller

Product ModelAPX1-G2
PH Range

0~14pH

ORP Range± 2000mV
Temperature Range

-10~150℃ /14~302℉

Resolution

0.01pH / 1mV/ 0.1℃

Accuracy

PH:±0.02 pH /ORP:±2 mV

Solution Grounding

It can eliminate the leakage interference of part of the solution

Stability

0.05% of the measurement range per 24 hours, no accumulation

Temp Compensation

NTC10K/PT1000 automatic selection or 25°C conversion manual selection

Sensor Diagnosis

Screen image display

Analog Current Output

2 channel 0/4~20mA,load 1000 ohms,and support long-term calibration

Relay Control

2 configurable SPST relays with a maximum load of 3A/250VAC

Digital communication

1 two-wire RS485 communication interface; MODBUS RTU

Screen Display

128*64 3.2-inch large graphic dot matrix LCD

Calibration method

pH: 3-point calibration/5-point calibration, ORP: 2-point calibration

quick calibration menu available

Operating Environment

0~60℃, RH< 95%

Storage Environment

-20~70℃, RH < 55%

Power Supply

AC: 100~240V 50/60Hz or DC:18~36V

Power Consumption3 W

Shell Material

Enhanced ABS

Size

100×100×120 mm(hole size 92*92mm)

Weight500g

Mounting Method

Panel installation

 

Temperature conversion:

 

Temperature conversion refers to converting the current measured pH value to the value when the temperature is 25℃. (Assuming that all other things are constant and only the temperature changes, the pH value required by many standards generally refers to the pH value at 25°C. As we said above, the pH value measured by our pH meter is the pH value at the current temperature, which will be deviated from the pH value at 25°C. The temperature coefficients of different solutions also differ greatly. Pure water is about 0.015pH/C, and the temperature coefficient of trace (mg/L grade) contaminated pure water rises to about 0.033pH/C. So in strict cases, you have to convert 25°C.

 

pH ORP controller Applications:

 

    In real life production, the control of pH value (pH) is a very important process. At the same time, with the strengthening of human awareness of environmental protection, the national requirements for environmental protection are becoming higher and higher, more and more attention, the control of wastewater discharge in the process of industrial production is more and more strict, a variety of biochemical indicators are included in the supervision, pH value is one of the very important indicators; If the pH value is too acidic or too alkaline discharged into the rivers, lakes and seas, it will cause irreversible impact on the water body and water ecology. The traditional manual pH value monitoring will gradually be replaced by automatic control because of the time and power consumption, and the control precision cannot be guaranteed. At the same time automatic control because of the use of high precision, long life pH meter to measure the pH value, so the control accuracy will reach a new height, conducive to pharmaceutical, chemical, electroplating and other factories in the production monitoring.

 

 

If you are interested in the product PH ORP controller APX1-G2, please contact us.

 

 

 

 

Hot Products

5 Points Multi-Slope Calibration And Differential Signal Solution Ground Analog PH/ ORP Controller ...
Analog PH/ ORP Controller With Historical data records and RS485 For Sewage Or Drinking Water pH ...
Analog PH/ ORP Controller With RS485 Two Relays Control Dosing For Sewage Or Drinking Water The pH ...
Online PH/ ORP Controller With Two Relays Control Dosing For Water Treatment Plant pH controllers ...
Online PH/ ORP Transmitter with RS485 Two Relays two 0/4~20mA Output For Sewage Or Drinking Water ...
Online PH/ ORP Controller With Differential Signaling Solution Grounding 5-Point Calibration For ...