300 VA Automated Peripheral Vision Test Equipment 1060 HPa Computer Instrument

Country/Region china
City & Province chongqing chongqing
Categories Electronics Production Machinery
InquireNow

Product Details

peripheral vision test equipment fully automatic computer vision instrument Support Windows XP, WIN7

 

 

peripheral vision test equipment absorbs the advantages of international advanced models, set acoustic, optical, mechanical, electrical technology in one, using large-scale integrated circuit design, using projection mode, visual marking using international general random detection mode, and has a wide inspection range (0-90°).The automatic vision instrument adopts high-end computer configuration, which is more stable and reliable than similar domestic products. peripheral vision test equipment has been recognized by many eye hospitals in China and widely used. It supports Windows XP and Win7 platforms, with beautiful software interface, simple operation and easy to learn and use by ophthalmologists.According to international standards, comprehensive software testing procedures and multiple report analysis are provided to assist in the diagnosis of diseases related to visual impairment.

 

Features of Automated Perimetry Machine

 

1. Comprehensive real-time monitoring, heiji-krakau physiological blind spot monitoring. Gaze tracking/head position tracking, automatic measurement of pupil diameter, reduce the impact of pupil effect on visual field detection.

2. Personalized design, accurate clinical analysis, accurate and rapid examination strategy.

3. Under international Goldman standard, providing a variety of calssic test procedures and report analysis.

 

Specifications:

Basic specification

 High-end computer configuration Automated Perimetry MachineAutomated Perimetry Machine

Inspection range

90°

Inspection distance

30cm

Background light brightness

White 31.5asb

Visual target brightness

1asb--- -10000asb

Visual target size

Goldmann III

Visual target interval time

200ms

Visual target interval time

Standard or adjustment according to patient reflection

Threshold test model

Center5-°16, center10° -68, 24 -2, 30-2, 30° -60° nasal step

Upper Threshold test model

30°- 40, 30°-76, P-60, 60°-81, 60°-120,190°-135 nasal side

Special detection strategy

Esterman monocular, Esterman binocular . user- customized test, 150P driver monocular fast detection, 150P driver monocular standard detection , upper 36 detection, blind spot detection,150horizontal straightness detection

Pupil size test

Automatic

Fixation monitoring

Blind spot monitoring , eye position eye position deviation alarm, eye deviation curve

Environment light detection

Automatic

Analysis software

Reliability analysis , single vision report, triple vision report, GPA half vision analysis, GPA glaucoma developing analysis , VFI vision index analysis

Operation system

Win7 above

 

Feature

Automated Perimetry Machine

1. Comprehensive real-time monitoring, heiji-krakau physiological blind spot monitoring. Gaze tracking/head position tracking, automatic measurement of pupil diameter, reduce the impact of pupil effect on visual field detection.

2. Personalized design, accurate clinical analysis, accurate and rapid examination strategy.

3. Under international Goldman standard, providing a variety of calssic test procedures and report analysis.

 

 

Transportation and storage

6.1visual field instruments with complete packaging can be transported by conventional means of transportation or as stipulated in the contract. During the transportation, precautions should be taken against moisture, sun protection, inversion and violent vibration and collision.

6.2 after packaging, the visual field instrument should be stored in the environment temperature range of 0 ℃ ~ 55 ℃, relative humidity ≤ 85%, atmospheric pressure range: 760 hPa ~ 1060 hPa, non-corrosive gas and clean room with good ventilation.

6.3 if the installed instruments need to be carried or moved over a short distance, the connecting wires between the instruments must be removed and carried separately. If the instrument needs to be transported for a long distance, it should be repacked into the original package for handling.

 

Company Introduction

 

 

 

 

Hot Products

non mydriatic retinal camera a field of view of 50 degrees for fundus imaging non mydriatic retinal ...
ultra wide field fundus camera Xenon lights Digital camera small pupil shooting function ultra wide ...
digital eye fundus camera high definition images 3.3mm small pupils Automated Fundus Camera RETICAM ...
ultra wide field fundus camera CE DICOM 3.0 Gamma,contrast,brightness,color of image can be adjusted ...
fundus photography equipment ultra wide field fundus camera with FFA/FAF Introductions: fundus ...
eye fundus camera automatic with intelligent operation simple and fast What can Automated Fundus ...