Digital Eye Fundus Camera 135° Wide Field Soft Lighting Intelligent Operation

Country/Region china
City & Province chongqing chongqing
Categories Other Cables
InquireNow

Product Details

digital eye fundus camera 135° wide field soft lighting automatic intelligent operation

 

digital eye fundus camera RETICAM 3100 is based on the traditional fundus camera of our company, after years of research and development, through binocular stereo vision and XYZ 3D image feature recognition automatic positioning, and through the division line to achieve automatic focus. Through CCD imaging feedback, the exposure light is measured and the exposure intensity is determined automatically and correctly. Focusing step is controlled according to the image resolution, and image definition is adjusted to obtain clear and accurate fundus image.Automated Fundus Camera RetiCam 3100 has excellent optical imaging capability, easy to operate, less dependence on the operator, easier to obtain images.

digital eye fundus camera RETICAM 3100  Fundus auto fluorescence (FAF), as a new retinal imaging technology, has been widely used in clinical medicine since its advent. It has been demonstrated that FAF can be used to diagnose and monitor many fundus diseases, including posterior uveitis, quickly and noninvasively.

As a new application of non-invasive, non-contact, non-invasive, rapid and repeatable observation and monitoring of many fundus diseases including posterior uveitis, FAF has begun to play its unique role, and has attracted more and more attention of ophthalmologists and medical technicians.

 

 

Acquisition ModesAutomated Fundus Camera/mydriatic Anterior photography /Red-free(optional)(FFA)/(FAF)
Field View50°
Working Distance35mm
Minimum Pupil≥3.3mm
Focus ModesManual/Auto
Alignment ModesDouble dots auxiliary
ExposureManual /Auto
PhotographySLR Camera
Image definition24 Megapixel
Compensation±25D
FixationExternal /Internal (any position available)
DICOM 3.0Support

 

For patients who have an allergic reaction to strong light or who cannot receive light stimulation, please consult the physicians before imaging.

                                               Automated Fundus Camera in the world
BrandTOPCON(NW-400)DRSNEWVISON(RETICAM3100)
operationautomatic(one key taking picutre)/manualautomatic(one key taking picutre)/manualautomatic(one key taking picutre)/manual
Acquisition modesfundus/anterior/?fundus/anterior/red-free filterfundus/anterior/red-free filter/FFA(optional)/FAF(optional)
Filed of view45 degree40-45degree45-50degee
Mosic degee 80 degree135degree
Minimum pipil size3.3mm3.5mm3.3mm
Resolutionabove 18megapiexlsensor size:5 megapixel sensor resoultion: 48 pixel/degreeabove18 megapixel (24 megapixel optional )
Fixation9 internal + 1 outside fixaiton7 internal fixationcountless fixaiton, any position is available during range + 1 outside fixation
Technology of focus  Dual camrea technology
exposure lighstandardstandardnew technology, more soft, one patient same eye can take picuture consecutive with almost same performace

 

 

 

 

Company Introduction

Focusing on the two major public health problems of adolescent myopia and elderly ophthalmology, our company researches new diagnostic and treatment equipment for ophthalmology, develops low-cost applicable technology products, realizes industrialization, reduces the cost of social medical and health system, and serves the strategic needs of national health.The company always adhere to the "high-tech,new vision" for the enterprise development concept.We have a strong technical force, has been awarded 11 patents, and obtained 13,485 quality system certification.Bio has established an efficient marketing team and a perfect after-sales service system to provide medical equipment with the highest cost performance and meticulous service.

Hot Products

non mydriatic retinal camera one click automatic FFA small pupil dual camera Automated Fundus Camera ...
digital eye fundus camera 135° wide field soft lighting automatic intelligent operation digital eye ...
automated fundus camera DICOM and AI system small pupil multifunctional software system Automated ...
non mydriatic retinal camera a field of view of 50 degrees for fundus imaging non mydriatic retinal ...
ultra wide field fundus camera Xenon lights Digital camera small pupil shooting function ultra wide ...
digital eye fundus camera high definition images 3.3mm small pupils Automated Fundus Camera RETICAM ...