Home Companies Chongqing Bio Newvision Medical Equipment Ltd.

Static Automated Perimetry Machine With Abundant Inspection Modes

Chongqing Bio Newvision Medical Equipment Ltd.

Contact Us

[China] country

Trade Verify

Address: 2nd floor of building #5, 27 Fengsheng Road, Jinfeng Town,High-Tech Industrial Development Zone, 401329 Chongqing, People's Republic of China

Contact name:Robert Wang

Inquir Now

Chongqing Bio Newvision Medical Equipment Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Static Automated Perimetry Machine With Abundant Inspection Modes

Country/Region china
City & Province chongqing chongqing
InquireNow

Product Details

Provide multiple report analysis Automated Perimetry Machine

 

BIO-1000 automatic computer vision instrument is developed by our R&D team to absorb the advantages of international advanced models. It integrates sound, light, mechanical and electrical technologies, adopts international general random detection mode for visual marking, and has a wide examination range (0-90°) to help doctors to judge the patient's eye condition more comprehensively.Automated Perimetry Machine Adopt the high-end computer configuration, compared with the domestic similar products, stability, reliability is higher.Support Windows XP, Win7 platform, beautiful software interface, simple operation, easy to learn and use.According to international standards, it provides a very comprehensive software testing program and multiple report analysis to assist in the diagnosis of diseases related to visual impairment and help to make a more accurate diagnosis
 
 Automated Perimetry Machine Specifications:
 

Basic specification

Provide multiple report analysis ​ Automated Perimetry Machine

Inspection range

90°

Inspection distance

30cm

Background light brightness

White 31.5asb

Visual target brightness

1asb--- -10000asb

Visual target size

GoldmannIII

Visual target interval time

200ms

Visual target interval time

Standard or adjustment according to patient reflection

Threshold test model

Center5-°16, center10° -68, 24 -2, 30-2, 30° -60° nasal step

Upper Threshold test model

30°- 40, 30°-76, P-60, 60°-81, 60°-120,190°-135 nasal side

Special detection strategy

Esterman monocular, Esterman binocular . user- customized test, 150P driver monocular fast detection, 150P driver monocular standard detection , upper 36 detection, blind spot detection,150horizontal straightness detection

Pupil size test

Automatic

Fixation monitoring

Blind spot monitoring , eye position eye position deviation alarm, eye deviation curve

Environment light detection

Automatic

Analysis software

Reliability analysis , single vision report, triple vision report, GPA half vision analysis, GPA glaucoma developing analysis , VFI vision index analysis

Operation system

Win7 above
 

Feature

Automated Perimetry Machine
1. Comprehensive real-time monitoring, heiji-krakau physiological blind spot monitoring. Gaze tracking/head position tracking, automatic measurement of pupil diameter, reduce the impact of pupil effect on visual field detection.
2. Personalized design, accurate clinical analysis, accurate and rapid examination strategy.
3. Under international Goldman standard, providing a variety of calssic test procedures and report analysis.
 

 
Features:

1,Multiple fixation monitoring programs to ensure high reliability

Comprehensive real-time monitoring, HeiJji-krakau physiological blind spot monitoring, gaze tracking/head position tracking, automatic measurement of pupil diameter, reduce the impact of pupil effect on visual field detection


2,Abundant inspection modes for both accuracy and speed
• Rich threshold inspection and suprathreshold inspection modes to detect earlier visual field defects
• The scientific and intelligent interactive inspection strategy improves your work efficiency. It only takes 3 minutes to inspect the 30°field of view.


3,Comprehensive Analysis Software
• 6 kinds of analysis: reliability analysis, single-report analysis, multi-report analysis, glaucoma half-field analysis, glaucoma progression analysis, VFI visual field index analysis;
• Half-field analysis designed for glaucoma, making glaucoma diagnosis easier
• Analysis of glaucoma progression, where very subtle progression is more visible and continues to suggest new progression


 
 
 
 
 
Company Introduction

 
























Hot Products

Digital Eye Fundus Camera retinal imaging camera fully automatic digital eye fundus camera RETICAM ...
Non Mydriatic Automatic Fundus Camera retinal fundus camera Small Pupil Imaging Red Free Non ...
High Resolution Optical Coherence Tomography Machine for Microscopic Imaging The Retiview 500 is an ...
Fully Display Three-Dimensional Structure Information Fundus Optical Coherence Tomography Machine ...
Compact Design No External Computer Is Needed Optical Coherence Tomography Machine Compared to other ...
High-end computer configuration Automated Perimetry Machine The Bio-1000 plus automated computer ...