Philip IntelliVue MP70 Patient Monitor LCD Display Frame Assemble M8000-65001

Country/Region china
City & Province guangzhou guangdong
InquireNow

Product Details

 

Philipilip IntelliVue MP70 Patient Monitor LCD display Frame assemble new version M8000-65001

 

 

►Brief Introduction

 

Philipilip IntelliVue MP70 Patient Monitor have color LCD TFT displays with a wide viewing angle, providing high resolution waveform and data presentation. Philipilip IntelliVue MP70 Patient Monitor integrate the display and the processing unit into one device. It is 38cm (15˝) color XGA monitor display with 4, 6 or 8 waveforms is bright and easy to read.

The Display Controller Interface consists of a video controller chip, video RAM and the controlling software. The Display Controller interface processes the high level display commands (character and graPhilipilipic generation, wave drawing) and translates them into pixels, which are written into the video RAM where the video controller chip generates the video synchronization signals and the pixel stream for the Color LCD Display.

 

 

 

Disassembly

1. Remove the bottom cover in Removing the ECG Out board if no SRL2 board is plugged.
2. Remove integrated module slot and measurement server mount as described in Removing the Integrated Module Slot, the Measurement Server Mount or blank covers.
3. Unplug the video cable by pulling downwards and the touch controller cable by pulling outwards on the tab.

4. Place the monitor in an upright position and pull off the display assembly.

Reassembly Note: When reassembling the monitor, make sure you insert the cables into the slots at the bottom of the assembly and to slide the display assembly into its hooks.

 

 

 

Integrated Touch Display not functioning

 

SymptomsPossible Causes of FailureFailure Isolation and Remedy
Touch Screen not functioningTouch controller cable not connectedCheck connection from the touch controller board to the main board
Touch panel cable not connectedCheck connection from touch controller board to touch panel
Touch controller board defectiveReplace touch controller board
Note: Linearization data must be loaded and recalibrated after replacing the touch controller
board
Touch Sensor defectiveReplace Touch Sensor
Main board defectiveReplace main board

 

 

 

►Shipment Arrangements

In order to make the deal runs successfully, please make it a point and manage your time of placing orders on the basis of your business needs. If you have any questions such as your order is taking much more time than expected or you need to know when will your order arrive, you can contact us at anytime. We will reply you as soon as possible.

 

As for delivery time, we will try our best to process the orders and ship them out as soon as possible. Please be patient and keep contact with us. Generally speaking, most orders will be shipped in 3 to 5 working days and can arrive on time. However, during the busy days the shipment may be delayed over 5 working days. If you are in urgent need of your item, please be sure to confirm with us before placing your orders. Thanks for cooperation.

 

 

Thank you for your time and interest in Philipilip IntelliVue MP70 Patient Monitor LCD display Frame assemble new version M8000-65001. "Quality assurance" is our eternal pursuit and promise. Don't be hesitant to contact us If you have any questions! Welcome to place your orders.

 

Hot Products

004-0004-004 2016792-002 REV A GE Dash4000 patient monitor display assembly 10.4inch Display ...
2026653-019 GE Dash3000 Dash4000 Dash5000 Patient Monitor Battery Door Battery door features High ...
P/N 2019271-001 GE Dash3000 Dash4000 Dash5000 Patient Monitor Display Flex Flat Cable About company ...
P/N 801394-001 GE Dash3000 Dash4000 Dash5000 Patient Monitor Power Supply Board The monitor ...
P/N 2026653-037 GE Dash3000 Dash4000 Dash5000 Patient Monitor Handle The handle has a variety of ...
P/N 1076374(1058272) Philipilip V60 Ventilator Battery 14.4V 11.0Ah 163Wh LOT M91484-P1 Install an ...