Home Companies China World Technology Medical Equipment Service Group

Hospital Medical Patient Monitor Accessories Philip M1604A CBL 5 Lead Snap Chest IEC ICU 989803144921

China World Technology Medical Equipment Service Group

Contact Us

[China] country

Trade Verify

Address: TianHe District,GuangZhou,GuangDong

Contact name:Kiara

Inquir Now

China World Technology Medical Equipment Service Group

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Hospital Medical Patient Monitor Accessories Philip M1604A CBL 5 Lead Snap Chest IEC ICU 989803144921

Country/Region china
City & Province guangzhou guangdong
Categories Connectors
InquireNow

Product Details

 

Hospital Medical Patient Monitor Accessories Philipilip M1604A CBL 5 Lead Snap Chest IEC ICU 989803144921  

 

 

 

► Brief Introduction

These products are intended for use only with Philipilip devices that are listed as accessories in the device's instruction manual. Additionally, they can be used with the following Philipilip/Agilent/HP devices: 78352C, 78354C, 78834C, M1001A/B, M1002A/B, M3000A, M3002A, M8102A, M8105A, 863063, 863064, 863065, 863066, 863068, 8630.

Electrode placement is color-coded in accordance with IEC 60601-2-27 and AAMI recommendations.

All ECG trunk cables can be used with AAMI or IEC color-coded lead sets. Electrode terminations are available with grappling hooks, snaps and mini clips.

This symbol indicates that the ECG cable, when used in combination with the above-mentioned monitors, is designed to have special protection against electric shock (especially with regard to the permissible leakage current) and is defibrillator-proof.

 

 

 

Specifications

LeadsProductDescriptionReusable/SingleLengthPackagingUse with:
5 chestM1604AICU, snapReusable1 m (3.3ft)1 each5+5 Trunk cable M1949A, M1663A

 

 

Electrode-to-Patient Contact

 

Poor electrode-to-patient contact can result in poor signal quality and relative waveforms, as well as false alarms. Poor contact could result from to poor skin preparation, dried electrode gel, and/or defective ECG cables or lead wires.

Keep in mind the following guidelines to ensure good contact:

  • Once attached, electrodes should not move in any way.
  • Check electrodes periodically for firm adhesion and complete contact. If an electrode moves easily, the electrode connection is too loose and may need to be changed.
  • Tape down the lead wire about 3-4 inches away from the electrode, with slack in the wire to prevent it from pulling on the electrode.

 

 

Lead Selection

It is important to select a suitable lead that shows the largest amplitude and cleanest signal so that a QRS complex and R-wave, in particular, can be accurately detected by the monitor. Consider the following lead selection guidelines:

  • The QRS complex should be tall and narrow (recommended amplitude > 0.5 mV).
  • The R-wave should be above or below the baseline (but not biPhilipilipasic).
  • The P-wave should be smaller than (1/5) R-wave height.
  • The T-wave should be smaller than (1/3) R-wave height.

To prevent detection of P-waves or baseline noises as QRS complexes, the minimum detection level for QRS complexes is set at 0.15 mV, according to AAMI-EC 13 specifications.

 

 

 

Customer satisfaction. Our biggest pursuit! If you want to explore more details about Philipilip M1604A CBL 5 Lead Snap Chest IEC ICU 989803144921, please let us know.

Hot Products

Hospital Medical Equipment Stryker Endoscopy X-6000 X6000 Xenon Light Source, 220-185-000 ►Brief ...
Refurbished GE DASH2000 Patient Monitor Standard Parameter For Sale GE Dash2000 device is designed ...
Hospital Medical Equipment Mindray BeneHeart R12 ElectrocardiograPhilipilip ECG Machine ► Brief ...
004-0004-004 2016792-002 REV A GE Dash4000 patient monitor display assembly 10.4inch Display ...
2026653-019 GE Dash3000 Dash4000 Dash5000 Patient Monitor Battery Door Battery door features High ...
P/N 2019271-001 GE Dash3000 Dash4000 Dash5000 Patient Monitor Display Flex Flat Cable About company ...