C2-8 Samsung Medison curved array Ultrasound Probe MySono U6, SonoAce R7, SonoAce R5, SonoAce R3

 

 

Samsung Medison C2-8 curved array ultrasound probe specializes primarily in both abdominal and OB-GYN (obstetrics and gynecological) application images. The C2-8 has a higher frequency range then most abdominal transducers - ranging from 2 MHz. to 8 MHz. It is compatible with a range of Samsung ultrasound machines, including the MySono U6, SonoAce R7, SonoAce R5, SonoAce R3.

 

 

 

Bandwidth2 – 8 MHz
Center of Frequency4.6 MHz
ApplicationsAbdomen, Obstetrics, Gynecology
Field of View68°
CompatibilityAccuvix XG, UGEO H60, MySono U6, SonoAce R7, SonoAce R5, SonoAce R3

 

 

Probe Precautions

 

The sensor can be easily damaged due to misuse or exposure to certain chemicals. Check the sensor cable, housing and lens before and after each use according to the instructions in the manual.

 

CAUTION:

  • Do not subject the sensor to mechanical shock.
  • Do not place the sensor cable on the floor where it can be pulled over the cable, such as the rollers. Do not bend or pull the cable with excessive force.
  • Do not immerse the sensor in unsuitable substances such as alcohol, bleach, ammonium chloride and hydrogen peroxide.
  • Do not expose the sensor to temperatures of +50 ° C or higher

 

Sensor use and infection control

 

Ultrasound scanners use ultrasound that is in direct contact with the patient during use. Depending on the type of examination, this contact may extend to several sites, including normal skin or blood transfusion sites during surgery.

The most effective way to prevent a patient from becoming infected is to use each probe only once.

However, the sensors may need to be reused due to their complex and expensive design. Therefore, it is necessary to use protective equipment, such as guards, and to follow the safety instructions carefully to minimize the patient's risk of infection.

 

Electric shock

 

The sensor consumes electricity. Contact with conductive materials poses a risk of electric shock to the patient or user.

 

Cleaning

Cleaning is an important process before disinfecting the sensor. The sensor must be cleaned after each use.

 

 

CAUTION:

  • Do not use surgical brushes to clean the sensor. Using a soft brush can also damage the sensor.
  • During the cleaning and disinfection process, the part of the sensor that is kept dry during the wetting process is higher than the other parts until all parts are dry. This prevents liquid from entering the leaking area of ​​the pipe.

 

1. Disconnect the sensor from the system.

2. Remove any biopsy adapters or needle guides. (The biopsy adapter can be reused and sterilized.)

3. Discard the cuff. (The lid is a disposable item.)

4. Lightly dampen it with a soft cloth dampened with a mild soap or compatible cleaning fluid, and remove any particles and body fluids left on the sensor or cable.

5. Remove residual particles by rinsing with water until submerged.

6. Clean with a dry cloth.

7. If necessary, clean with a cloth dampened with water to remove soap residue.

 

Disinfection

Disinfect only the vaginal and rectal probes. Following the disinfection procedures in this manual and using the following solutions recommended by Samsung Medison, pathogens should be reduced by 10-6

1. Store, use, and dispose of the disinfectant in accordance with the instructions on the disinfectant label.

2. Mix a disinfectant compatible with the probe according to the solution strength instructions.

3. As shown in the figure below, immerse the probe in the disinfectant.

4. Follow the instructions on the disinfectant to rinse the probe after the soaking process is complete.

5. Air-dry the probe or wipe it with a clean cloth.

 

Hot Products

3D4-8ET Samsung Medison Ultrasound Probe for Accuvix V20. Accuvix V10. SonoAce R7 Live 3D. SonoAce ...
Mindray IMEC7 Patient Monitor With ECG, RESP, NIBP, SpO2, PR, TEMP Parameters Mindray iMEC 7 patient ...
Hospital Medical Equipment Used Patient Monitor Edan SE-2003 SE-2012 Holter System ► Brief ...
Hospital Medical Equipment Stryker Endoscopy X-6000 X6000 Xenon Light Source, 220-185-000 ►Brief ...
Refurbished GE DASH2000 Patient Monitor Standard Parameter For Sale GE Dash2000 device is designed ...
Hospital Medical Equipment Mindray BeneHeart R12 ElectrocardiograPhilipilip ECG Machine ► Brief ...