Home Companies China World Technology Medical Equipment Service Group

Mindray City MOX-4 MOX4 O2 Oxygen Sensor Cable 122009708

China World Technology Medical Equipment Service Group

Contact Us

[China] country

Trade Verify

Address: TianHe District,GuangZhou,GuangDong

Contact name:Kiara

Inquir Now

China World Technology Medical Equipment Service Group

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Mindray City MOX-4 MOX4 O2 Oxygen Sensor Cable 122009708

Country/Region china
City & Province guangzhou guangdong
Categories Control Cables
InquireNow

Product Details

Mindray MOX-4 Oxygen Sensor Cable 122009708

 

 

About Mindray MOX-4 Oxygen Sensor Cable 122009708

 

The Mindray MOX-4 Oxygen Sensor Cable is a replacement cable used with the Mindray MOX-4 oxygen sensor. This cable is designed to

 

provide a reliable connection between the sensor and the monitoring device, ensuring accurate and consistent oxygen level readings. It is an

 

 

essential component for patient monitoring in hospital settings and healthcare facilities.

 

 

Specification of Mindray MOX-4 Oxygen Sensor

 

MEASUREMENT
Operating PrinciplePartial pressure electrochemical
Output9 mV to 13 mV in 210 mBar O2
Measurement Range0 mBar to 1500 mBar O2
Baseline Offset<200 μV
ENVIRONMENTAL
Typical ApplicationsCritical care anesthesia
Operating Temperature RangeRange -20°C to +50°C
Operating Pressure Range0.5 Bar to 2.0 Bar
Operating Humidity Range0% to 99% RH noncondensing

 

 

 

Purpose of use

These sensors are designed for oxygen partial pressure monitoring in anesthesia (except xenon), intensive care, neonatal incubators and general

 

oxygen monitors.

 

 

 

Stabilization time.

 

Wait at least 15 minutes for the instrument to stabilize before calibrating or refer to the manufacturer's instructions.

 

 

 

Cleaning and sterilization

 

If the sensor is dirty, clean it with distilled water and allow it to air dry. This sensor is not suitable for steam sterilization or exposure to chemicals

 

such as ethylene oxide or hydrogen peroxide.

 

 

 

Calibration interval

 

If the sensor is dirty, clean it with distilled water and allow it to air dry. This sensor is not suitable for steam sterilization or exposure to chemicals

 

such as ethylene oxide or hydrogen peroxide.

 

 

 

If you drop the sensor

 

If a sensor is dropped, it must be isolated for 24 hours and then a two-point calibration performed.

 

 

mechanical installation

 

When installing the sensor, simply screw it in tightly by hand to ensure a tight seal. Do not use wrenches or similar mechanical devices as

 

excessive force may damage the sensor threads.

 

 

Photos 

 

Below picture is Mindray City MOX-4 MOX4 O2 Oxygen Sensor Cable 122009708 New .The cable condition is new .

 

 

 

 

About us

 

CWT Technology HK Limited is a developing company ,mainly selling patient monitor ,ECG ,defibrillator ,ultrasound ,spare parts ,accessories

 

.With the developing ,our customers are from all over the world,such as USA ,Italy ,Spain ,Malaysia ,Philippines,Indonesia ,Thailand ,Colombia

 

,Saudi Arabic ,United Arab Emirates ,Oman etc .

 

 

Thank you so much for your attention .If you're interested in Mindray MOX-4 MOX4 O2 Oxygen Sensor Cable 122009708 ,feel free to contact us .Thank you .

Hot Products

Mindray Pulse Oximeter PM-60 Brief Introduction of Mindray Pulse Oximeter PM-60 The PM-60 is a ...
Sino-K Medical SPH100 Handheld Spo2 Finger Tip Pulse Oximeter product features: The working ...
Olympus EVIS LUCERA CV-260 Endoscopy Endoscopy Function 1. Suction connector Connect the endoscope ...
Biolight BLT AnyView A5 Patient Monitor Modular Buckle ► About Biolight BLT AnyView A5 Patient ...
Mindray BIS LOC 2 Channel Cable Assembly 6800-30-50761 185-1014-MR 0010-21-42759 ► Brief Introductio...
Mindray BeneHeart D6 Defibrillator Machine ► Brief Introduction The Mindray BeneHeart D6 Defibrillat...