Home Companies China World Technology Medical Equipment Service Group

Metrax Primedic M240 DM1 Defibrillator SpO2 Module Includes Connecting Cable And SpO2 Module

China World Technology Medical Equipment Service Group

Contact Us

[China] country

Trade Verify

Address: TianHe District,GuangZhou,GuangDong

Contact name:Kiara

Inquir Now

China World Technology Medical Equipment Service Group

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Metrax Primedic M240 DM1 Defibrillator SpO2 Module Includes Connecting Cable And SpO2 Module

Country/Region china
City & Province guangzhou guangdong
Categories Solar Chargers
InquireNow

Product Details

 

Metrax Primedic M240 DM1 Defibrillator SpO2 Module

 

Metrax Primedic M240 DM1 Defibrillator SpO2 Module,Includes Connecting Cable And SpO2 Module

 

►Quick Detail:

The SPO2 module is used for sampling examination or measuring the patient's blood oxygen saturation and pulse rate. For average blood oxygen saturation, the low-power module can send instantaneous blood oxygen saturation. Its detection speed is very efficient and the SPO2 module is compatible with all BCI probes. This module is suitable for measuring blood oxygen saturation and pulse rate in infants, newborns and adults.

 

 

►There are several inspection methods:

If there is a fault, there will be no blood oxygen waveform or blood oxygen value.

 

1. Replace the blood oxygen probe. If it doesn't work, the blood oxygen probe or blood oxygen extension cable may be faulty.
2. Check whether the blood oxygen probe model matches.
3. Check whether the red light of the blood oxygen probe is flashing. If it does not flash, the probe assembly is faulty.
4. If a blood oxygen "initialization error" alarm occurs, the blood oxygen module is faulty.
 

If the finger probe does not have a red light flashing, it may be a poor contact at the wire interface. It is recommended to check extension cords and socket connections. In areas with lower temperatures, try not to expose the patient's arms to avoid affecting the detection effect. Blood pressure measurement and blood oxygen measurement should not be performed on the same arm to avoid pressure on the arm and affect the measurement results. If the blood oxygen display waveform channel displays "No signal reception", it means there is a problem with the communication between the blood oxygen module and the host. Please close and then open again. If this prompt continues to appear, the blood oxygen module needs to be replaced.

 

If the SPO2 value is low or inaccurate, there are several checking methods:

1. First we have to ask whether this is a specific case or a general phenomenon. If it is a special situation, you can consider how to avoid it from the precautions of blood oxygen measurement, such as patient movement, poor microcirculation, hypothermia, too long time, etc.
2. If this is a common situation, please try to replace the blood oxygen probe. It may be caused by a faulty blood oxygen probe.
3. Check whether the blood oxygen extension cable is damaged.
Try to keep the patient as stable as possible. Once the blood oxygen value is lost due to hand movements, it is considered normal. If the blood oxygen extension cable is damaged, please replace it with a new one.

 

 

 

 

 

 

►features:

 

 

BrandPrimedic
TypeM240 DM1 Defibrillator SpO2 Module
Warranty period90 Days
Shipping Date3-5 Working Days
size18*16cm
Storage temperature-20-70°c

 

 

About delivery:

 

We default to express delivery by DHL,Fedex, We will contact you as soon as possible when sending express delivery. If you have any questions after receiving the express delivery, please feel free to contact us at any time.

 

 

 

 

 

 

 

 


 

Hot Products

Goldway UT4000F PRO Patient Monitor Philip Goldway UT4000F PRO Patient Monitor By GOLDWAY INDUSTRIAL ...
Goldway UT4000F PRO Multi-parameter patient monitor Goldway UT4000F PRO Multi-parameter patient ...
Mindray Pulse Oximeter PM-60 Brief Introduction of Mindray Pulse Oximeter PM-60 The PM-60 is a ...
Sino-K Medical SPH100 Handheld Spo2 Finger Tip Pulse Oximeter product features: The working ...
Olympus EVIS LUCERA CV-260 Endoscopy Endoscopy Function 1. Suction connector Connect the endoscope ...
Biolight BLT AnyView A5 Patient Monitor Modular Buckle ► About Biolight BLT AnyView A5 Patient ...