GE Mac1200ST ECG Machine Display SP14Q002-A2

 

Quick Detail:

This monitor is for use with GE Mac1200ST electrocardiogram model SP14Q002-A2. It is very accurate to use it to sample. It has 24-bit sampling accuracy and a sampling frequency of up to 34khz. The display is very clear. The color display is basically the same as other color display structures. Basically, the 'pixel units' arranged in a matrix constitute the luminous body of the display screen; each 'pixel unit' contains red, green and blue light-emitting tubes; under the management of the 'matrix control circuit', it can display text, color images, Video, video. The main advantages of the display screen are: high brightness; long life; large viewing angle; easy to interface with computers and supports rich software; waterproof and moisture-proof; low-voltage drive, safe and energy-saving; environmentally friendly; flexible shape, as long as the shape of the substrate is changed, it can be satisfied Various forms of display requirements.

 

All information that appears on the screen of the GE Mac1200ST ECG Machine is displayed through this display, namely the patient's vital sign data. The display will display data including respiratory data, ECG data, blood pressure data, blood oxygen data, pulse data and other data. And it can be displayed according to the mode you set, such as wave mode. After successful setting, the patient's waveform physical characteristic data will be displayed on the display. It greatly facilitates medical staff's understanding of patient data, thereby helping them treat patients better.

 

► Working principle

 

GE Mac1200ST ECG Machine Display SP14Q002-A2
The working principle is relatively complex and has rich high-tech content. Its interface consists of video control chip, video RAM and control software. The display controller interface handles display commands within the device, such as instructions for character and graphics generation, or waveforms, and then converts these instructions into specific pixels. These pixels are written to the video RAM and then the controller chip generates the video and synchronizes these signals and pixels to the color LCD on the patient monitor. You can see changes in patient vital sign data on the patient monitor.

 

Display features:

1. Anti-glare brightness 140 cd/m (Typ.)
2. Comparison 25:1(Typ.)
3. Six points in the direction of the viewpoint
4. Response time 120/150(Typ.)(Tr/TD)
5. Observation angle 40 (Typ.) (CR≥2, Φ2-Φ1)
6. Operating mode STN, black/white (negative), transmission
7.Support color monochromatic light source CCFL[1 PC]

When the display shows:

Note: ECG monitoring is only for monitoring heart rate and heart rhythm changes. If you need to analyze ST segment abnormalities and observe ECG changes in more detail, you should do a conventional lead ECG.

GE Mac1200ST ECG Machine Display SP14Q002-A2 perform observations by detecting heart rate, blood pressure, blood oxygen saturation, and respiratory rate.

 

1. Heart rate: Generally, the top of the screen is the human body’s heartbeat waveform curve. The normal value is 60-100 beats/min. It can determine the person’s heart rate and the occurrence of arrhythmia.

2. Blood pressure: The second line on the ECG monitor screen is blood pressure, and the number displayed is the blood pressure value.

3. Blood oxygen saturation: The single number displayed on the screen is the blood oxygen saturation, and the normal value is 90-100%.

4. Respiration rate: There will be a curve at the bottom of the screen that rises and falls with the chest as you breathe, and the number to the right is the number of breaths. The normal respiratory rate for adults is 12 to 18 breaths/minute.

 

You can choose lead I, II or III for ECG monitoring. The most commonly used lead is lead II: abipolar lead with electrodes on the right arm and left leg. It is most useful for detecting arrhythmias because its direction is closest to the direction of the heart's electrical axis(the total vector direction of the current), and the shapes of P waves and R waves are also the clearest. Organize supplies and bed units.

 

 

 

 

If an alarm occurs on the ECG monitor, it means that the value is abnormal and the doctor needs to be notified as soon as possible to provide corresponding treatment.

 

Product cleaning and protection

 

When cleaning the instrument, do not use chemicals

Thinner or solvents such as benzene to avoid damaging the deep surface of the instrument.

Check instrument performance regularly.

Product parameters:

Be applicable:

GE Mac1200ST ECG Machine Display

Model:

SP14Q002-A2

Sampling accuracy

24 bit

Sampling frequency

32kHz

common mode rejection ratio

>105dB

Scaling voltage

<±2%

monitor:

8-inch TFT color LCD display

Check item

electrocardiogram

Package

a display

 

 

 

user target audience:

 

Patients whose condition is critical require continuous and uninterrupted monitoring of heart rate, rhythm, body temperature, pulse,respiration, blood pressure, and transcutaneous blood oxygen saturation. Or it can be used solely for ECG and blood pressure monitoring in order to understand the condition in time (patients over three years old)

 

About delivery:

 

We default to express delivery by DHL. We will contact you as soon as possible when sending express delivery. If you have any questions after receiving the express delivery, please feel free to contact us at any time.

About ordering

 

If you have any questions about the GE Mac1200ST ECG Machine Display SP14Q002-A2 , please call or email us .

 

 

 

 

 

 

 

 


 

Hot Products

Goldway UT4000F PRO Patient Monitor Philip Goldway UT4000F PRO Patient Monitor By GOLDWAY INDUSTRIAL ...
Goldway UT4000F PRO Multi-parameter patient monitor Goldway UT4000F PRO Multi-parameter patient ...
Mindray Pulse Oximeter PM-60 Brief Introduction of Mindray Pulse Oximeter PM-60 The PM-60 is a ...
Sino-K Medical SPH100 Handheld Spo2 Finger Tip Pulse Oximeter product features: The working ...
Olympus EVIS LUCERA CV-260 Endoscopy Endoscopy Function 1. Suction connector Connect the endoscope ...
Biolight BLT AnyView A5 Patient Monitor Modular Buckle ► About Biolight BLT AnyView A5 Patient ...