GE Mac1200ST electrocardiograph side cover
Quick Detail:
Start by checking the model side cover for compatibility with your
specific device, as the design may vary between models.
When installing the side cover, first cut off the power and make
sure the side cover of the GE Mac1200ST electrocardiograph is clean
and free of other stains. Then find the position of the side cover
of the GE MAC 1200ST electrocardiograph, put the side cover in and
tighten it, and check whether the electrocardiograph can work
normally.
How to use the GE Mac1200ST electrocardiograph is as follows:
1.Preparation
(1) Skin preparation: The skin where the electrode is attached
should be undamaged. If necessary, shave the hair, scrub the skin,
and use the skin preparation paper on the electrode pad to remove
dead skin.
(2) Place the electrode pads in the correct position on the
patient's body.
(3) Connect the wires and electrode sheets. Make sure the monitor
is powered on.
2. Placement of electrode pads
(1) Three leads: LA (left arm) electrode - left midclavicular line,
subclavian area or upper left limb connecting to the trunk; FL
(left leg) electrode - left midclavicular line, 6th and 7th
intervening area or left hip; RRA (right Arm) Electrode - the right
midclavicular line, subclavian area or the part where the right
upper limb connects to the trunk;
(2) Five leads: LA (left arm) electrode - left midclavicular line,
subclavian area or the part where the left upper limb connects to
the trunk; R/RA (right arm) electrode - right midclavicular line,
subclavian area or where the left and right limbs connect to the
trunk ; FLL (left leg) electrode - right midclavicular line, sixth
and seventh intercostal space or right hip; NRL (right leg)
electrode - left midclavicular line, sixth and seventh intercostal
space or left hip; CN (chest) electrode - electrocardiogram chest
Lead location.
3. Setting menu
Heart rate source: Can be set to ECG, SPO2, automatic, and
simultaneous. You can choose ECG or SPO2 to detect heart rate;
choose to have the monitor automatically determine the heart rate
source based on signal quality. When the signal quality is the
same, ECG takes priority; choose both to display HR and PR at the
same time, and display the measurement value of PR on the right
side of the main screen SPO2. Waveform velocity trace There are
three speeds: 12.5, 25, and 50mm/s. Usually choose 25mm/s.
4. Respiratory monitoring function
When discharging the electrodes, place the two breathing electrodes
on the right midaxillary line and the left side of the thorax.
These two places have the greatest activity during breathing and
can obtain the best respiratory waves.
5.SPO2 monitoring function
Measure blood oxygen saturation. Choose fingers with good nail bed
conditions. The probe wire is placed on the back of the hand. Do
not place the sensor on a limb that has an arterial catheter or
intravenous line, and do not place the blood oxygen probe and blood
pressure cuff on the same limb.
6.NIBP monitoring function
The blood pressure cuff and monitor inflation tube should be kept
unobstructed. Deflate all cuffs before measurement. Place the mark
on the cuff on the appropriate artery. The cuff should not be
wrapped too tightly. Do not measure blood pressure on an IV or
cannulated limb. The NIBP monitoring function displays systolic
blood pressure, diastolic blood pressure, mean blood pressure, and
pulse rate; NIBP has functions such as manual measurement,
automatic measurement, and midway stop measurement.
Parameter Description:
PRODUCT NAME: | GE Mac1200ST electrocardiograph side cover |
APPLICATION: | Medical Equipment,ICU,hospital |
WARRANTY: | 90days |
USAGES: | ICU, Emergency, Patient Monitor, ICU Room And Operating Room |
PREPONDERANCES: | Specialized Engineers With 12 Years Of Experience |
Minimum order quantity | one piece |
Transportation method | international express |
Material | ABS plastic |
About contact delivery:
We will provide satisfactory service for all your needs as soon as
possible. Thank you for your attention. If you are interested in A
pair of white plastic GE Mac1200ST electrocardiograph
side corver, please feel free to contact us to place an
order for delivery!