Home Companies China World Technology Medical Equipment Service Group

GE Mac1200ST electrocardiograph side cover for GE Mac1200ST electrocardiograph,White plastic,

China World Technology Medical Equipment Service Group

Contact Us

[China] country

Trade Verify

Address: TianHe District,GuangZhou,GuangDong

Contact name:Kiara

Inquir Now

China World Technology Medical Equipment Service Group

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

GE Mac1200ST electrocardiograph side cover for GE Mac1200ST electrocardiograph,White plastic,

Country/Region china
City & Province guangzhou guangdong
Categories Monitoring & Diagnostic Equipment
InquireNow

Product Details

 

GE Mac1200ST electrocardiograph side cover

 

Quick Detail:

Start by checking the model side cover for compatibility with your specific device, as the design may vary between models.

 

When installing the side cover, first cut off the power and make sure the side cover of the GE Mac1200ST electrocardiograph is clean and free of other stains. Then find the position of the side cover of the GE MAC 1200ST electrocardiograph, put the side cover in and tighten it, and check whether the electrocardiograph can work normally.

 

How to use the GE Mac1200ST electrocardiograph  is as follows:

1.Preparation

(1) Skin preparation: The skin where the electrode is attached should be undamaged. If necessary, shave the hair, scrub the skin, and use the skin preparation paper on the electrode pad to remove dead skin.

(2) Place the electrode pads in the correct position on the patient's body.

(3) Connect the wires and electrode sheets. Make sure the monitor is powered on.

2. Placement of electrode pads

(1) Three leads: LA (left arm) electrode - left midclavicular line, subclavian area or upper left limb connecting to the trunk; FL (left leg) electrode - left midclavicular line, 6th and 7th intervening area or left hip; RRA (right Arm) Electrode - the right midclavicular line, subclavian area or the part where the right upper limb connects to the trunk;
(2) Five leads: LA (left arm) electrode - left midclavicular line, subclavian area or the part where the left upper limb connects to the trunk; R/RA (right arm) electrode - right midclavicular line, subclavian area or where the left and right limbs connect to the trunk ; FLL (left leg) electrode - right midclavicular line, sixth and seventh intercostal space or right hip; NRL (right leg) electrode - left midclavicular line, sixth and seventh intercostal space or left hip; CN (chest) electrode - electrocardiogram chest Lead location.

3. Setting menu
 

Heart rate source: Can be set to ECG, SPO2, automatic, and simultaneous. You can choose ECG or SPO2 to detect heart rate; choose to have the monitor automatically determine the heart rate source based on signal quality. When the signal quality is the same, ECG takes priority; choose both to display HR and PR at the same time, and display the measurement value of PR on the right side of the main screen SPO2. Waveform velocity trace There are three speeds: 12.5, 25, and 50mm/s. Usually choose 25mm/s.

4. Respiratory monitoring function


When discharging the electrodes, place the two breathing electrodes on the right midaxillary line and the left side of the thorax. These two places have the greatest activity during breathing and can obtain the best respiratory waves.
5.SPO2 monitoring function
Measure blood oxygen saturation. Choose fingers with good nail bed conditions. The probe wire is placed on the back of the hand. Do not place the sensor on a limb that has an arterial catheter or intravenous line, and do not place the blood oxygen probe and blood pressure cuff on the same limb.
6.NIBP monitoring function
The blood pressure cuff and monitor inflation tube should be kept unobstructed. Deflate all cuffs before measurement. Place the mark on the cuff on the appropriate artery. The cuff should not be wrapped too tightly. Do not measure blood pressure on an IV or cannulated limb. The NIBP monitoring function displays systolic blood pressure, diastolic blood pressure, mean blood pressure, and pulse rate; NIBP has functions such as manual measurement, automatic measurement, and midway stop measurement.

 

 

Parameter Description:

 

PRODUCT NAME:

GE Mac1200ST electrocardiograph side cover

APPLICATION:

Medical Equipment,ICU,hospital

WARRANTY:

90days

USAGES:

ICU, Emergency, Patient Monitor, ICU Room And Operating Room

PREPONDERANCES:

Specialized Engineers With 12 Years Of Experience

Minimum order quantity

one piece

Transportation method

international express

Material

ABS plastic

 

 

 

About contact delivery:

 

We will provide satisfactory service for all your needs as soon as possible. Thank you for your attention. If you are interested in A pair of white plastic GE Mac1200ST electrocardiograph  side  corver, please feel free to contact us to place an order for delivery!

 

Hot Products

Goldway UT4000F PRO Multi-parameter patient monitor Goldway UT4000F PRO Multi-parameter patient ...
Mindray Pulse Oximeter PM-60 Brief Introduction of Mindray Pulse Oximeter PM-60 The PM-60 is a ...
Sino-K Medical SPH100 Handheld Spo2 Finger Tip Pulse Oximeter product features: The working ...
Olympus EVIS LUCERA CV-260 Endoscopy Endoscopy Function 1. Suction connector Connect the endoscope ...
Biolight BLT AnyView A5 Patient Monitor Modular Buckle ► About Biolight BLT AnyView A5 Patient ...
Mindray BIS LOC 2 Channel Cable Assembly 6800-30-50761 185-1014-MR 0010-21-42759 ► Brief Introductio...