                              New and Original philip M2741A CO2 Sensor

                   New and Original philip M2741A CO2 sensor Medical Equipment For Hospital

 

Product Description

 

philip M2741A LoFlo Sidestream etCO2 bruger sensors
sofistikeret infrared absorption spectroscopy to measure
etCO2 and respiratory rates. lever sensors in clear,
Practical capnogram for respiratory rate up to 150 vejrtrækninger
I minute. Og med en tested at 50 ml/min he det det
Ideal for brug with spædbørn and fewer patients.
LoFlo sidestream etCO2 sensors Bruges together with philip
kapnografimåling serverudvidelse (M3014A) in
Combination with IntelliVue Multi-Måleserserveren.
philip tilbyder Luftvejsadaptersæt til intuberede patient
the increasing number of estimates of your etCO2 level. nose up
Kanyler oral-nasal that tilgængelege to ikke-intuberede patient
some known procedures.

 

 

 

BrandphilipModel NO.M2741A
ColorWhiteCertificationCE
TypeSensorOriginUnited States
ConditionNew Original-GoodMOQ1 pcs
Warranty90 daysShip Time3-5 days

 

 

 

Use Procedure

 

1. Connect the m2741a CO2 sensor to the patient monitor. Connect the sample line and the lime.
Hose to the sensor. Make sure the sensor is disconnected from the patient circuit.
2. Turn on the patient monitor.
3. Go to monitor service mode.
Performance testing
3 testing and maintenance 89
4. Use sensor status given in m2741a serial protocol, wait for m2741a
The sensor heats up to operating temperature.
5. Reboot the sensor. Make sure that there is no gas in the air of the room
6. Connect a flow-controlled gas mixture of 5% CO2, n2 balance, to the calibration tube.
7. Turn off gas correction.
8. Wait a few seconds for the gas mixture to stabilize and monitor the CO2 level.

 

 

 

Product Features 

 

1. Application environment: ideal for general service, intensive care,CCU, ER, OU and EMS
2.Compatibility: The M2741A sensor is compatible with any IntelliVue Patient Monitor Series (Version D.0 or later)
3. Reliability: Provides clear and accurate etCO2 measurement
4. Reliability: solid solid state design
5. Innovative: sample cup and filter attached to
disposable sampling kits that prevent contamination of liquids sensor
6.Easy: plug-and-play function; intuitive and easy to use,does not require regular calibration

 

Product Details

 

 

 

 

 

 

 

 

 

 

                  If you are interested in New and Original philip M2741A CO2 Sensor,please feel free to contact us.

        If you have any questions about the New and Original philip M2741A CO2 Sensor, please feel free to contact us.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hot Products

philip VM6 LVDS cable 10 philip VM6 LVDS cable Medical Equipment For Hospital Product Description: ...
GE Dash 4000 Patient Monitor GE Healthcare DASH 4000 Patient Monitor Medical Equipment Good Working ...
philip CAPNOSTAT M2501A Patient Monitor CO2 Sensor philip CAPNOSTAT M2501A Patient Monitor CO2 ...
COMEN C60 Neonatal Patient Monitor Used for Hospital About COMEN C60 patient monitor COMEN C60 has ...
Used Mindary VS-600 VS600 Vital Signs Patient Monitor for Adult Pediatric Neonatal ❖ Mindray VS-600 ...
Medical Fetal Monitor Parts philip FM20 Fetal Monitor Cover Protector M2703-44150 philip FM20 Fetal ...