GE Marquette Mainstream CAPNOSTAT CO2 Sensor 412340-002 ECG Machine Accessories

Country/Region china
City & Province guangzhou guangdong
InquireNow

Product Details

GE Marquette Mainstream CAPNOSTAT CO2 Sensor

GE Marquette Mainstream CAPNOSTAT CO2 Sensor 412340-002 ECG Machine Parts

 

Brief Description

The GE Marquette Mainstream CAPNOSTAT CO2 Sensor is used in connection with the GE ECG Machine to measure the CO2 concentration data of patients for reference by medical staff. Its working principle is very simple, it mainly uses the selective absorption theory of molecules for carbon dioxide gas molecules, and the gas concentration can be measured according to the absorption intensity of light. According to the theory of selective absorption of gases, when the emission wavelength of the light source coincides with the absorption wavelength of the gas, the phenomenon of resonance absorption will occur, and the absorption intensity is related to the concentration of the gas, and the concentration of the gas can be directly measured after measuring the absorption intensity of light. It is such a connected sensor, one end of which is connected to GE's ECG monitoring equipment, and the other end is connected to the patient, and the patient's CO2 concentration data can be measured.

 

 

 

Measurement

The GE Marquette CAPNOSTAT CO2 Sensor uses the mainstream method to measure the patient's end-of-breath CO2 concentration. There are three common measurement methods in healthcare settings, including mainstream, sideflow, and microfluidic measurement hands-off. This sensor is the mainstream measurement method of choice. Mainstream measurement is characterized by real-time monitoring, no time delay, and the patient's CO2 concentration can be measured directly in the main exhalation duct through the sensor. Although it needs to be fixed, the measured data is very accurate. Therefore, the GE Marquette CAPNOSTAT CO2 Sensor is a sensor device that is very suitable for clinical medicine.

 

 

 

Specifications

BRAND NAMEGE
PACKAGINGCarton
WARRANTY90 Days
PRODUCT CATEGORYECG Parts
ITEM NO.412340-002
ColorGrey

 

 

 

► Detailed photos

 

 

 

 

► Instructions

Before using the GE Marquette Mainstream CAPNOSTAT CO2 Sensor, please make sure that it is working properly and free of any damage. Otherwise, the measurement results will be inaccurate, and even affect the patient's life, health and safety. After use, it should also be properly cleaned and disinfected in time for continued use.However, the prescribed cleaning and disinfection reagents must be used, and it is forbidden to use unapproved reagents, otherwise the sensor may be damaged.

 

 

 

 

 

 

 

 

Thank you for your interest in GE Marquette Mainstream CAPNOSTAT CO2 Sensor 412340-002 ECG Machine Parts. If you are interested in our products, please feel free to contact me.We will happy to serve you.

Hot Products

philip VM6 LVDS cable 10 philip VM6 LVDS cable Medical Equipment For Hospital Product Description: ...
GE Dash 4000 Patient Monitor GE Healthcare DASH 4000 Patient Monitor Medical Equipment Good Working ...
philip CAPNOSTAT M2501A Patient Monitor CO2 Sensor philip CAPNOSTAT M2501A Patient Monitor CO2 ...
COMEN C60 Neonatal Patient Monitor Used for Hospital About COMEN C60 patient monitor COMEN C60 has ...
Used Mindary VS-600 VS600 Vital Signs Patient Monitor for Adult Pediatric Neonatal ❖ Mindray VS-600 ...
Medical Fetal Monitor Parts philip FM20 Fetal Monitor Cover Protector M2703-44150 philip FM20 Fetal ...