GE Invasive Pressure IP Adapter cable IBP Tram 451 Dual Adaptor 0.3 Meter REF 2005772-001

 

 

► Brief Introduction

The dual invasive blood pressure adapter is intended to be used for connection two invasive blood pressure transducers to GE Medical System Information.

Work for GE B20 B20i B40 B105 B125 Modules. Cath-Lab, MAC-Lab, Dash 1000, Dash 2000, Dash 3000, Dash 3100, Dash 4000, Dash 5000, Eagle, Solar 7000, Solar 8000, Solar 9000, Tram 451, Tram Module 100-600, Tram Rac 3, Tram Rac 4A, Tram Scope 100-800 A, Tram Scope 100-800 L

To measure invasive blood pressure, a catheter is inserted into an artery or vein. The invasive pressure setup, consisting of a connecting tubing, a pressure transducer, an intravenous bag of normal saline, all connected together by stopcocks, is attached to the catheter. The transducer is placed at the same level with the heart, and is electrically zeroed.

The transducer is a piezo-resistive device that converts the pressure signal to a voltage. The monitor interprets the voltage signal so that pressure data and pressure waveforms can be displayed.

 

 

Invasive blood pressure measurement

Configure the simulator’s IBP channels as follows:

Sensitivity: 5 µV/V/mmHg

InvBP outputs: "0 mmHg static pressure" or "atmosphere"

  • Zeroing
  • Press IBP Zero All key.
  • Check that a message "Zeroing" followed by a message "Zeroed" is shown in the IBP parameter window.
  • Static Pressure
  • Configure the simulator's InvBP output to "200 mmHg static pressure".
  • Check that the flat pressure line appears on the related waveform field. The reading in the parameter window shall be 200 ±10 mmHg.

NOTE: Recalibration is required, if the measured value is not within the specification.

  • Pressure Waveforms
  • Configure the simulator's InvBP output to "Arterial 120/80".
  • Check that the pressure waveform for tested invasive pressure channel appears in the IBP waveform field and the Sys/Dia (Mean) pressure values are shown in the related parameter window.

 

 

► Invasive blood pressure connectors (IBP1, IBP2)

1BP_+VREFBP transducer excitation voltage, channel 1
2BP SIG+BP transducer signal positive (+), channel 1
3BP_+VREFBP transducer excitation voltage, channel 2
4AGNDAnalog ground
5BP SIG+BP transducer signal positive (+), channel 2
6SHIELDBP cable shield
7AGNDAnalog ground
8BP SIG1BP transducer signal negative (-), channel 1
9BP SIG2BP transducer signal negative (-), channel 2
10BP1_IDBP1 probe identification
11NCNot connected

 

 

 

If you have other inquiry of GE Invasive Pressure IP Adapter cable IBP Tram 451 Dual Adaptor 0.3 Meter REF 2005772-001, please feel free to contact us.

We are always ready to serve you.

Hot Products

philip VM6 LVDS cable 10 philip VM6 LVDS cable Medical Equipment For Hospital Product Description: ...
GE Dash 4000 Patient Monitor GE Healthcare DASH 4000 Patient Monitor Medical Equipment Good Working ...
philip CAPNOSTAT M2501A Patient Monitor CO2 Sensor philip CAPNOSTAT M2501A Patient Monitor CO2 ...
COMEN C60 Neonatal Patient Monitor Used for Hospital About COMEN C60 patient monitor COMEN C60 has ...
Used Mindary VS-600 VS600 Vital Signs Patient Monitor for Adult Pediatric Neonatal ❖ Mindray VS-600 ...
Medical Fetal Monitor Parts philip FM20 Fetal Monitor Cover Protector M2703-44150 philip FM20 Fetal ...