Home Companies China World Technology Medical Equipment Service Group

Edan F9 Fetal & Maternal Monitor Hospital Medical Equipment Parts

China World Technology Medical Equipment Service Group

Contact Us

[China] country

Trade Verify

Address: TianHe District,GuangZhou,GuangDong

Contact name:Kiara

Inquir Now

China World Technology Medical Equipment Service Group

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Edan F9 Fetal & Maternal Monitor Hospital Medical Equipment Parts

Country/Region china
City & Province guangzhou guangdong
InquireNow

Product Details

 

Hospital Medical Equipment Edan F9 Fetal & Maternal Monitor

 

 

 

► Brief Introduction

The F9 Fetal & Maternal Monitor is intended for non-invasive and invasive monitoring of fetus during antepartum examination, labor and delivery. It is intended to be used only by trained and qualified personnel in antepartum examination rooms, labor and delivery rooms.

F9 Fetal & Maternal Monitor provides Non-Stress testing for pregnant women. It can externally monitor the FHRs using ultrasound and uterine activity via a TOCO transducer. Alternatively, it can internally monitor one of the FHRs with DECG and uterine activity with an IUPC.And it is intended for providing Non-Stress testing or fetal monitoring for pregnant women. In addition, it provides a solution for maternal vital signs monitoring.

 

 

► Overview

.

1Keys
2Transducer
3Sockets
4Alarm Indicator
5Display Screen
6Control Knob
7Charge, AC, Power Indicator
8Paper Drawer

9Accessory Holder
10MECG Socket
11NIBP Socket
12DECG Socket
13US2 Socket
14EXT.1 Socket
15MARK Socket
16US1 Socket
17TOCO Socket
18SpO2 Socket
19TEMP Socket

 

 

► Confirming Fetal Life

Fetal monitoring with ultrasound or DECG cannot differentiate a fetal heart rate signal source from a maternal heart rate source in all situations. These are some of the signal sources that might be taken as FHR signal source by mistake:

  • High maternal heart rate signal.
  • Maternal aorta or other large vessels signals.
  • Electrical impulse from the maternal heart transmitted through a recently deceased fetus.

These are some of the signal sources that might be taken as fetal movement signal source by mistake:

  • Movement of the ultrasound transducer.
  • Movement of the deceased fetus during or following manual palpation of fetal movement.
  • Movement of the deceased fetus during or following maternal movement.

So you need to confirm fetal life by other means before starting to use the fetal monitor, such as using a fetoscope, stethoscope, Pinard stethoscope or obstetric ultrasonography.

 

 

 

► Delivery Instructions

As a general rule, all the orders are going to be shipped within 3 to 5 working days and delivered on time. Of course sometimes there are some special circumstances. For instance, on busy days the shipment will be postponed. But no worries, all the orders will be dispatched finally. We will make great efforts to process the orders and ship them out as soon as possible. Please stay patient and keep in touch with us. If you need the product to be shipped urgently, please make sure you talk to us in advance before placing your orders. In order to make the deal runs successfully, please make it a point and manage your time of placing orders on the basis of your business needs. If you have any questions such as your order is taking much more time than expected or you need to know when will your order arrive, you can contact us at anytime. We will reply you as soon as possible. Your satisfaction is our biggest wish.

 

 

 

We seek for providing perfect service to the satisfaction of customers. Thank you for your time! If you are interested in Edan F9 Fetal & Maternal Monitor, welcome to place your orders. Early order early shipment!

Hot Products

philip VM6 LVDS cable 10 philip VM6 LVDS cable Medical Equipment For Hospital Product Description: ...
GE Dash 4000 Patient Monitor GE Healthcare DASH 4000 Patient Monitor Medical Equipment Good Working ...
philip CAPNOSTAT M2501A Patient Monitor CO2 Sensor philip CAPNOSTAT M2501A Patient Monitor CO2 ...
COMEN C60 Neonatal Patient Monitor Used for Hospital About COMEN C60 patient monitor COMEN C60 has ...
Used Mindary VS-600 VS600 Vital Signs Patient Monitor for Adult Pediatric Neonatal ❖ Mindray VS-600 ...
Medical Fetal Monitor Parts philip FM20 Fetal Monitor Cover Protector M2703-44150 philip FM20 Fetal ...