Home Companies Guangzhou YIGU Medical Equipment Service Co.,Ltd

Oxygen Medical Equipment Spare Parts Rad 9 Model Oximeter

Guangzhou YIGU Medical Equipment Service Co.,Ltd

Contact Us

[China] country

Trade Verify

Address: Room 206, Jin Hao Zhi Ying centre Buliding, Fengxin Road NO.1, Science avenue, Luo Gang District Guangzhou Guangdong China

Contact name:chamY

Inquir Now

Guangzhou YIGU Medical Equipment Service Co.,Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Oxygen Medical Equipment Spare Parts Rad 9 Model Oximeter

Country/Region china
City & Province guangzhou guangdong
Categories Solar Chargers
InquireNow

Product Details

White good quality Oxygen Rad-9 Model oximeter

 

  • Description:

Brand Name: 

 

Name: Oxygen Rad-9 Model oximeter

 

Payments:TT/Western Union or Paypal

 

Shipments:DHL/EMS/FedEx

 

Shipping Time:Within 1-3work days

 

 

we are also selling power supply, printer, high voltage board, blood oxygen board, ECG board, keypress board, mainboard, NIBP board (pump) of mindray PM series monitor. Do let us know your kind enquiry. Do not hesitate to contact with us for futher information.

 

 

Company Business Scope

  • A. ECG monitor, Fetal monitor, Defibrillator, Electrocardiograph, Oximeter for repairing and accessories for selling.
  • B. Mainboard, Power Stripe/Panel, Touch Screen, Viewing screen, Button Board, ECG/Oximeter/Blood Press Module for repairing and selling.
  • C. Medical Patient Monitor/Electrocardiograph for leasing, maintenance, guarantee repair and exchange.

 

Common Faults Repair

  • 1. Unbootable/ Unable to boot up 2. The module ( M3001A ) can’t detect blood pressure.
  • 3. The module can’t be connected. 4. Automatically disconnect.
  • 5. The sphygmomanometer has a leak. 6. NIBP equipment failure.
  • 7. Unable to contact. 8. Error reporting MMS disconnected.
  • 9. False alarm MMS pull out. 10. Can’t load out.
  • 11. ECG malfunctions. 12. ECG equipment out of order.
  • 13. Software upgrades. 14. NIBP fails to inflate.
  • 15. IBP equipment faults. 16. M3012A module can’t be detected.
  • 17. Automatically restart. 18. The encoder can’t work.
  • 19. Blue screen appears after startup. 20. No ECG signal.
  • 21. Unable to enter the select menu. 22. Alarm occurs when starting up, and the failure light is on.
  • 23. Report CO2 plugging. 24. MMSL developing module faults.
  • 25. M3015A / M3001A module faults. 26. No power display light.
  • 27. NBP equipment faults. 28. ECG and oximeter equipment faults.
  • 29. LCD lamp aging. 30. Inflated blood pressure does not indicate a number.
  • 31. The key plate is out of order. 32. Encoder failure.
  • 33. Can’t inflate. 34. NIBP equipment faults.
  • 35. SP O2 and ECG equipment fault. 36. Unable to charge.
  • 37. The touch screen can’t work. 38. The screen shows double image.
  • 39. Error code 1000. Error code 20004. 40. No alarm sounds.

 

Business Scopes
Repairing Services
Monitor, ECG, Defibrillator, Oximeter, Electrocardiograph, Fetal monitor and spare parts
Sell and ReplaceMainboard, Circuit board, Power strip/ panel, Battery, SP O2 and ECG module, Parameter module, Display screen, Touch screen, Encoder, Keyboard plate, Sensor, Probe, Cable etc.
Service Brands
GE, , SPACELABS, SIEMENS, MINDRAY, NIHON KOHDEN, MEDTRONIC, TYCO, NONIN, TOSHIBA, MEDISON, BIOSOUND, HITACHI, HP, ATL, ALOKA etc.


1. Maintenance Services:


ECG monitor, Defibrillator, Oximeter, Electrocardiograph, Fetal monitor

2. Sell and Replace:


Mainboard, Circuit board, Power strip/ panel, Battery, SP O2 and ECG module, Parameter module, Display screen, Touch screen, Encoder, Keyboard plate, Sensor, Probe, Cable etc.

3. Service Brands:


GE, , SPACELABS, SIEMENS, MINDRAY, NIHON KOHDEN, MEDTRONIC, TYCO, NONIN, TOSHIBA, MEDISON, BIOSOUND, HITACHI, HP, ATL, ALOKA etc.

 

 

  • Agilent M1460A Sensor, Intellivue G5-M109A, Intellivue MX40,
  • M1205A , M1001A, M1012A, M1034A, M3001A, M3012A,M3014A, M3015A,M3046A,
  • MP2 X2,MP20,MP30, MP40, MP5, MP50 , MP60, MP70, MP80, MP90,
  • V24E(M1204A), VM4, VM6, VM8,VS2+, VS3
GE

 

  • B20, B20i, B30, B40, B40i, B650, B850,
  • DASH1800, DASH2000, DASH2500, DASH3000, DASH5000, Cardiocap 5,
  • Datex-Ohmeda S3/S4/S5, GE DT-4500, Marquette EAGLE 4000,
  • PRO1000, PRO300,
  • SOLAR8000, SOLAR8000i, SOLAR8000M,
  • V100, SAM Smart, SAM80
Nihon Kohden

 

  • BSM-2301A, BSM-2301K, BSM-2304A, BSM-2351A, BSM-2351C, BSM-4104A, BSM-5106A
  • GF-210R, MU-631KA, WEP-4204K, WEP-4208A
Mindray

 

  • IMEC8, IMEC10, IMEC12,
  • IPM8, IPM10, IPM12, IPM9800, MEC-1000, MEC-1200, MEC-200, MPM,
  • PANORAMA, PM6000, PM1000, PM8000, PM8000E, PM9000, PM9000E,
  • T1, T5, T6, T8, VS-800
Spacelabs

 

  • 90309, 90369, 90518,91369, 91370, 91387, 91388, 91393, 91496, 91518,
  • elance93300,mCare300
Siemens
  • SC6002,SC6000,SC7000,SC6002 XL
Tyco
  • NBP4000, NBP4000C

Hot Products

Drager patient monitor High pressure plate About YIGU MED Guangzhou YIGU Medical Equipment Service ...
GE B40 B650 PDM Modules with spo2 in stocks for Medical Repairing Replacement Parts ICU Equipment ...
Medical Patient Monitor Repairing Spacelabs Ultraview DM3 Patient Monitor With Spo2 In Stocks For ...
Description: Rad-8 Oximeter Medical equipment Brand Name: Name: Rad-8 Oximeter · Notes from company: ...
GE CAM S-5 Patient Monitor Fan for Patient Monitor Spare Parts The GE CAM (Central Acute Monitoring) ...
Medical Equipments X2 Patient Monitor Spo2 Spare Parts In Stocks For Selling And Repairing Services ...