Home Companies Guangzhou YIGU Medical Equipment Service Co.,Ltd

M3046A M4 Used Patient Monitor In Good Physical And Functional Condiction

Guangzhou YIGU Medical Equipment Service Co.,Ltd

Contact Us

[China] country

Trade Verify

Address: Room 206, Jin Hao Zhi Ying centre Buliding, Fengxin Road NO.1, Science avenue, Luo Gang District Guangzhou Guangdong China

Contact name:chamY

Inquir Now

Guangzhou YIGU Medical Equipment Service Co.,Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

M3046A M4 Used Patient Monitor In Good Physical And Functional Condiction

Country/Region china
City & Province guangzhou guangdong
Categories Solar Chargers
InquireNow

Product Details

Used Monitor M3046A M4 Patient Monitor in Good Physical and Functional Condiction

 

Maintenance Services

 

we are providing repairing service for the patient monitors/defibrillators/sensors/ECG/Fetal monitors for the brands like: /GE/Spacelabs/Mindray/Nihon Kohden/Endoscopy ect.

 

 

Company Strengths

 

1. We are able to provide all kinds of medical equipment parts, hospital devices, patient facility accessories and complete machines.

2. We are able to offer maintenance service by professional medical equipment engineer with over 10 years specialized skills.

3. We have been solved more than 90% of MP series medical patient monitor module malfunctions (including software and hardware), and repair M3001A modules more than 400 pcs every year.

4. We deal with all medical patient monitors’ main brands including: GE, , SPACELABS, SIEMENS, NIHON KOHDEN, MINDRAY, Endoscopy, TYCO, NONIN etc.

5.Our principle: integrity and pragmatic, efficient and innovative, fearless and careful, professional service.

 

Common Faults Repair
1. Unbootable/ Unable to boot up2. The module ( M3001A ) can’t detect blood pressure.
3. The module can’t be connected.4. Automatically disconnect.
5. The sphygmomanometer has a leak.6. NIBP equipment failure.
7. Unable to contact.8. Error reporting MMS disconnected.
9. False alarm MMS pull out.10. Can’t load out.
11. ECG malfunctions.12. ECG equipment out of order.
13. Software upgrades.14. NIBP fails to inflate.
15. IBP equipment faults.16. M3012A module can’t be detected.
17. Automatically restart.18. The encoder can’t work.
19. Blue screen appears after startup.20. No ECG signal.
21. Unable to enter the select menu.22. Alarm occurs when starting up, and the failure light is on.
23. Report CO2 plugging.24. MMSL developing module faults.
25. M3015A / M3001A module faults.26. No power display light.
27. NBP equipment faults.28. ECG and oximeter equipment faults.
29. LCD lamp aging.30. Inflated blood pressure does not indicate a number.
31. The key plate is out of order.32. Encoder failure.
33. Can’t inflate.34. NIBP equipment faults.
35. SP O2 and ECG equipment fault.36. Unable to charge.
37. The touch screen can’t work.38. The screen shows double image.
39. Error code 1000. Error code 20004.40. No alarm sounds.

 

 

Company Business Scope:

 

ECG monitor, Fetal monitor, Defibrillator, Electrocardiograph, Oximeter for repairing and accessories for selling. Mainboard, Power Stripe/Panel, Touch Screen, Viewing screen, Button Board, ECG/Oximeter/Blood Press Module for repairing and selling. Medical Patient Monitor/Electrocardiograph for leasing, maintenance, guarantee repair and exchange.

 

Hot Products

Ventilator Pb840 PSOL Valve PN 4-071800-00K The PB840 PSOL Valve is a crucial component of the ...
MX450 monitor keypad with speaker [453564271771] The MX450 monitor keypad with speaker is a ...
Coman C50 Monitor Keypad PN 051-000292-00 The Coman C50 monitor keypad is a key control panel for ...
Mindray DRYLNE Adult Pediatric WATER TRAP 040-003877-00 The Mindray DRYLNE Adult Pediatric WATER ...
MIndray water trap for 9200-10-10530 Adult Pediatric Anesthesia Gas Module Generally speaking, the ...
GE CO2 module Water trap M1182629 Dark Steel Teal the water trap used in a CO2 module for anesthesia ...