Characteristics:

 

HY2850 can monitor variety of parameters such as the intracranial pressure,

blood pressure, blood oxygen saturation, pulse, per fusing pressure in encephalon,

pressure volume synchronously. It is either used in the neurosurgery of hospitals

or acted as the independent monitor of multi-parameter body symptom.

 

1. Monitoring the parameter such as intracranial pressure, cerebral perfusion pressure,

blood pressure, blood oxygen, pulse, pressure volume.

2. Imported blood oxygen saturation module and is suitable for the bad conditions such

as weak perfusion, low body temperature, serious Blood loss.

3. 10.4" TFT color display, Windows interface, operating in the touch screen.

4. 30 mins waveform replay in real-time, 72 hours waveform replay of intracranial

pressure tendency in real time.

5.255 groups data list sheet for blood pressure, blood oxygen saturation degree.

6. Store 30 zero-positions of fiber probe, auto-checking breakdown.

7. The printing output connector for waveform and data, alarming if exceeding the

parameter limit.

8. Intracranial pressure information transmitted by fiber, the temperature is not drifted.

 

Specification

Pulse measuring range40bpm~235bpm resolution: 1bpm error & le; 4bpm
Blood oxygen saturation degree measuring range40~99%, resolution: 1%, error & le; 2%
Intracranial pressure measuring range-5kPa+20kPa
Whole range measuring error& le; 250Pa
Zero point repetition& le; 0.1kPa
Blood pressure measuring range20mmHg~240mmHg
Standard ConfigurationMain unit epidural/subdural probe
OptionVentricle probe

 

Features
1. Pulse measuring range: 40bpm~235bpm resolution: 1bpm error & le; 4bpm
2. Blood oxygen saturation degree measuring range: 40~99%, resolution: 1%, error & le; 2%
3. Intracranial pressure measuring range: -5kPa+20kPa
4. Whole range measuring error: & le; 250Pa
5. Zero point repetition: & le; 0.1kPa
6. Blood pressure measuring range: 20mmHg~240mmHg
Standard Configuration: Main unit epidural/subdural probe
Option: Ventricle probe

Hot Products

Code (Size) 7170-1016L ¢10×160mmL 7170-1016R ¢10×160mmR 7170-1020L ¢10×200mmL 7170-1020R ¢10×200mmR ...
Product Describtion Tibial Intramedullary Nail, Titanium Orthopedic Interlocking Nail, Trauma ...
Proximal Femoral Nail, Anti-rotation (PFNA), Orthopedic Implant PFNA Intramedullary Nail, Femoral ...
Proximal Femoral Nail, Anti-rotation (PFNA), Orthopedic Implant PFNA Intramedullary Nail, Femoral ...
Interlocking Nails, Titanium Surgical Trauma Implant Interlock Gamma Nail, Orthopedic Trauma ...
Interlocking Nails, Titanium Surgical Trauma Implant Interlock Gamma Nail, Orthopedic Trauma ...