Main Technical Parameters:
Measurement Range | Non-transparence N 0~99.9% Ray absorption
coefficient K 0~16.06m-1 |
Resolution | Non-transparence N 0.1%
Ray absorption coefficient K 0.01m-1 |
Indicated error | Non-transparence N ±2.0%(absolute
error) |
Power | AC 220V±10%;50Hz±1Hz |
Weight | Test Unit 7.5Kg
Control
Unit 5Kg(include printer) |
Volume | Core Unit 610 * 500 * 330mm Donkey Unit 500 * 350 * 330mm |
Effective Optical Path Length | 215mm±0.1mm |
Preheat Time | 15min |
Main Function
1.Meet the requirements GB3847-2005
2.Plates imported funcitional group can store 500 measurements,
real-time clock.
3.Fission structure, measurement and control unit, conenient and
simple.
4.Opacity and absorption coefficient, N & K, convenient, simple
operation.
5.LCD large screen display, Chinese/English menu clew operation
6.Free acceleration experiments and adopts the transient
measurement function, and automatic 7.processing of test data and
display measurements.
7.Preheat 15 mins, and automatic zero
8.Test unit adopts shunt technique, test the diesel smoke
level.Using “air curtain ” technique to protect optical systems
against pollution.Temerature control to prevent condensation ,
ensure accuracy of masurements.
9.Built-in printer, real-time easurements of query and print.
10.RS-232C interface, convinent networking.
11.Gas temperature and engine speed Optional configuration.