Home Companies HUATEC GROUP CORPORATION

Digital Vibration Calibrator Calibrate Vibration Meter Non Destructive Testing Equipment HG-5020

HUATEC  GROUP  CORPORATION

Contact Us

[China] country

Trade Verify

Address: 7th Floor, Chengyuan Building B, the Mid. Road of Jiancaicheng Haidian Dist.BeiJing,CHINA 100096

Contact name:Shifen Yuan

Inquir Now

HUATEC GROUP CORPORATION

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Digital Vibration Calibrator Calibrate Vibration Meter Non Destructive Testing Equipment HG-5020

Country/Region china
City & Province beijing beijing
Categories Electric Wrenches
InquireNow

Product Details

Digital Vibration Calibrator Calibrate Vibration Meter , Vibration Analyzer / Tester ISO10816 HG-5020
Frequency(continually adjustable): 10 to1280Hz +0.01%


Application for ISO10816 HG-5020 Vibration Calibrator:

1.Can be used to calibrate vibration accelerometer, velocity and proximity transducer and also a vibration measuring instruments. Standard sine signals at frequency 10, 20, 40, 80, 160, 320, 640 and 1280 Hz

2.Can be generated from the calibrator the amplitude of the acceleration, velocity and displacement

3.Can be defined through potentiometers and shown on digital displays. Either horizontal or vertical vibration can be generated.

4.HG-5010 vibration calibrator combines sine signal generator, power amplifier, standard transducer and a shaker in one and features a small volume, high accuracy and easy operation. It can be used either in laboratory or on site.

5. International standards: ISO10816


Specifications:

Frequency: Not fixed, Frequency(continually adjustable): 10 to1280Hz +0.01%
Unit:
Acceleration: m/s2 (PEAK)
Velocity: mm/s (RMS)
Displacement: um (PK-PK)
Amplitude accuracy:
Acceleration (30m/s2 pk, 80Hz) 40Hz to 320Hz + 0.3dB + 1digit
10Hz to 1280Hz + 0.5dB +1digit
Velocity ( 25mm/sec pk ,80Hz) 40Hz to 320Hz +0.5dB +1digit
Displacement (10μm pk-pk, 80Hz) 40Hz to 320Hz + 0.5dB + 1digit
Proximity probe linearity
Prode: 5mm and 8mm probes Range: 0~4.0mm
Display: 3 1/2 digit display for acceleration, velocity or displacement
Maximum vibration amplitude and maximum load:
Because of the vibrostand used in HG-5010 Vibration Calibrator is rather small, during the calibration of transducers of different weight under different frequencies the output amplitude of the calibrators are also different. Maximum vibration amplitude and maximum load are related to the maximum acceleration. Maximum velocity and maximum displacement output generated from the calibrator under a certain frequency and with a certain weight of the transducer to be calibrated. The specific figures can be seen in the following table.

Wt

Freq
<100g<250g<650g
a(m/S2)v(mm/S)d(μm)a(m/S2)v(mm/S)d(μm)a(m/S2)v(mm/S)d(μm)
10Hz2.52813003.54018004452000
20Hz1585190010601300528640
40Hz6017020003510011001235380
80Hz10014180040603201420110
160Hz7553150352570128.524
320Hz501825301015103.55
640Hz3053203.5261*
1280Hz232*100.9*50.4*

Note: With higher frequency the value of the displacement of vibration is very small so there will be no vibration signal output from the calibrator.

 

Size: 280 x 180 x 250(mm)

Weight: 20lb,9kgs

Temperature: Operation: 0oC to 50 oC

Storage: -20 oC to 70 oC

Humidity: 90% non -condensing


The control panel of HG-5020 Vibration Calibrator is shown as following:

 

1 Vibration amplitude output display Showing the amplitude of the different vibration signal output of the calibrator
2 Calibration potentiometer
3 Function selecting switch Shifting the output of the calibrator to acceleration, velocity or displacement
4 Potentiometer for adjusting the output amplitude
Adjusting the potentiometer to change the output vibration amplitude
5 Adjusting the the output vibration amplitude slowly
6 The table for fixing the transducer to be calibrated
7 The thread hole for fixing the stand of proximity probe
During the calibration of proximity probe, the stand of the transducer is fixed on the control panel through this thread hole.
8 Power switch 220 VAC
9 Socket for 220 V AC power input
Used for connecting 220 V AC power.
10. Socket for power output
For monitoring the wave shape of the output signal of the power amplifier of the calibrator.
11 Output socket of – 24 V voltage
Providing power at – 24 V for proximitor during the calibration of proximity probe.
12 Frequency selecting switch

 

1

 

Fixing stand

 

2

 

 

Spindle micrometer

 

3

 

 

Tool to fix the sensor

 

4

 

 

Testing plate

 

5

 

M5 Fixing screw

 

6

 

M5-M8 Transition screw

 

7

 

M5-M10 Transition screw

 

 

Hot Products

Unique Multiple-wave check method TG5500DL Series Ultrasonic Thickness Gauge Usage Widely used to ...
Automatic self-calibration TG4000B Ultrasonic Thickness Gauge Usage Widely used to measure the ...
Advantage for measuring the thin piece and high precision measuring TG4100B Ultrasonic Thickness ...
Digital Vibration Calibrator Calibrate Vibration Meter Vibration Analyzer Vibration Tester ISO10816 ...
Digital Vibration Calibrator Calibrate Vibration Meter , Vibration Analyzer / Tester ISO10816 HG...
HG5003 Vibration Calibratorcan be used to calibrate small vibration transducers and also vibration ...