Gas Chromatograph – Mass Spectrometer (Quadrupole) with new ion optics system

 

Brief introduction of NBXD-8010:

Applications

The excellent performance of the GC-MS 3200 makes it suitable for applications in various fields including food safety, environmental safety, chemicals, among others.

1 Detection of Melamine in Milk
The detection limit is stable at 0.01 mg/kg. Linearity remains excellent between 0.05 - 50 mg/L. Recovery of added standard is between 85% - 108%. Relative standard deviation is less than 5%. Correlation coefficient is above 0.999. Results comply with GB / T 22388-2008 standard.

 

2 Analysis of Volatile Organic Compounds (VOC) in Drinking Water or Surface Water
Using external standard method, range of linearity is 0.5 - 100 μg/L. Correlation coefficient of each component is between 0.993 ~ 0.9992. The lowest detection limit is 0.001 mg/L for vinyl chloride. The instrument shows excellent performance in VOC analysis of drinking water in compliance with EPA method 502.2 and GB5749-2006.

 

3 Detection of Plasticizer in Liquors
16 types of phthalates in liquor are analyzed simultaneously. Range of linearity is 0.08 - 1.6 ug/mL. Recovery of added standard is between 70% - 119%. The lowest detection limit achieved is 1.06 ug/kg for DEP. Shows excellent contamination resistance. After 1 month of continuous use, background signal remains within spec.

 

4 Trace PAHs Detection
Linear correlation coefficient is more than 0.999 in the concentration range of 0.05 - 0.5 ug /mL.
Relative standard deviation is less than 6%. The lowest detection quality for benzopyrazole is 0.05 ng.

5 Detection of Organochlorine Pesticide

In ion monitoring mode, the analysis of organochlorine pesticide provides reliable data. Range of linearity is 0.012 - 0.2 ug/mL. Relative standard deviation is less than 10%. Lowest detection concentration reaches 0.012 ug/L.

6 Rapid Semi-quantitative Analysis of Hydrocarbons

7 Qualitative Analysis of Unknown Samples Using Direct Injection Probe

Working Conditions
l Power220 V, 50 Hz
l Temperature15℃-35℃
l Humidity25%-80% RH
Specifications
Gas Chromatograph
l Column oven temperatureRoom temperature + 10℃-400℃
l Temperature stability≤±0.03℃
Maximum heating rate40℃/min
Maximum run time999.99 min
10-segment programmable temperature control
l Split/splitless inlet (3rd generation EPC)
Maximum temperature: 400℃
Electronic controlled pressure, flow rate and split ratio
Pressure range: 0-999 kPa
Flow range: 0-200 mL/min
Autosampler (optional)
Mass Spectrometer
l Main Specifications
Mass range1.5 - 1024.0 amu
Mass stabilityBetter than 0.1 amu/48 h
ResolutionUnit mass
Sensitivity

DB-5MS 30m*0.25mm*0.25um fused silica capillary column or similar column.

EI source, full scan: (range 100-300 amu).

1 pg OFN S/N≥100:1

Maximum scan rate10,000 amu/s
Dynamic range105
l Ion source

Electron impact ionization source (EI), standard.

Chemical ionization source (CI), optional.

Dual filamentsProgrammable switch
Maximum filament current3 A
Emission current10 – 350μA adjustable
Ionization energy5 – 150eV adjustable
Ion source temperature150 – 320℃ adjustable, individually controlled
l Mass analyzer

Quadrupole.

Full scan, selected ion monitoring (SIM) and acquisition.

At most 128 groups in SIM mode.

At most 128 ions in each group.

l Detectorelectron multiplier + high-energy dynode back focusing assembly
l GC-MS interface
Individually controlled through transmission cable, 150 – 320℃ adjustable
l Vacuum system
Turbo molecular pump (250 L/s), mechanical pump (180 L/min)
Wide range compound cold cathode gauge
l Data processing system
HardwareComputer (optional)
PrinterLaser printer (optional)
SoftwareMS3200RT Real-time data acquisition application and MS3200P data processing application

Optional Accessories

 

DIP 100 liquid/solid direct injection probe assembly
Thermal desorption device
Dynamic headspace sampler
Purge-and-trap sample concentrator

 

                         

Hot Products

-10℃ ~ -40℃ 90 liters 4 drawers for easy storage medical Freezer NB-FL90 Freezer -10℃ ~ -40℃ Usage & ...
-40 degree 270 liters ultra low temperature laboratory freezer NB-FL270 Lab Freezer Usage & ...
-20~-40 degree Ultra-low Temperature Freezer Medical Freezer NB-FL450 Freezer -10℃ ~ -40℃ Usage & ...
Vacuum Freeze Dryer Vacuum Dryer Manufacturer Price Laboratory Vacuum Pilot Freeze Dryer Lyophilizer ...
Electrical Heating LCD Display Vacuum Freeze Dryer Lyophilizer Machine Characteristics of Vacuum ...
Lyophilizer Manufacturers Vacuum Function Freeze Dryer NB-10N Freeze Dryer Characteristics: ●Accord ...