10/0.4KV 3-phases oil type power transformer 30-2500KVA ISO IEC GB

Product Introduction

The oil-immersed transformer is one of the important pieces of equipment in the power supply and distribution system of industrial and mining enterprises and civil buildings. It reduces the 10(6)kV or 35kV network voltage to the 230/400V bus voltage used by the user. This type of product is suitable for AC 50 (60) Hz, three-phase maximum rated capacity 2500kVA (single-phase maximum rated capacity 833kVA, single-phase transformer is generally not recommended), can be used indoors (outdoor), when the capacity is 315kVA and below Can be installed on a pole, the ambient temperature is not higher than 40℃, not lower than -25℃, the highest daily average temperature is 30℃, the highest annual average temperature is 20℃, the relative humidity does not exceed 90% (ambient temperature 25℃), altitude No more than 1000m. If it is inconsistent with the above conditions of use, appropriate quota adjustments should be made in accordance with the relevant provisions of GB6450-86.

 

Features
1. The transformer iron core greatly reduces the no-load loss and no-load current, and the iron core is bound to ensure the tightness of the iron core and reduce noise.
2. The high and low voltage windings are made of oxygen-free copper, and the low voltage windings of 500kVA and below adopt a double-layer cylindrical structure. 630kVA and above adopt double-spiral or quad-spiral structure, and high-voltage winding adopts multi-layer cylindrical structure.
3. The transformer connection group uses Dyn11 to reduce the impact of harmonics on the power grid and improve the quality of power supply.
4. The transformer is a fully sealed structure, which prolongs the service life, does not need to hang the core and is free of maintenance.
5. The measured noise value is lower than the standard.
After this series of transformers are transported normally, the relevant parts can be installed without core checking, and the acceptance test can be carried out, and they can be put into operation after being qualified.

 

Product Standards

GB1094.1-2013
GB1094.2-2013
GB1094.3-2003
GB1094.5-2008
GB/T1094.10-2003
GB/T25446-2010

 

Performance characteristics
a. The low-voltage windings of oil-immersed transformers generally adopt a cylindrical structure with copper foil around the shaft, except for the small-capacity copper wires; the high-voltage winding adopts a multi-layer cylindrical structure to balance the ampere-turn distribution of the winding and cause leakage. Small, high mechanical strength, strong short-circuit resistance.
b. The iron core and the winding are each adopted with fastening measures. The fastening parts such as the height of the device and the low-voltage lead are equipped with self-locking lock nuts, and the non-suspending structure is adopted to withstand the shock of transportation.
c. The coil and iron core are vacuum dried, and the transformer oil is vacuum filtered and oiled to minimize the moisture inside the transformer.
d. The oil tank adopts corrugated sheet, which has a breathing function to compensate for the volume change of the oil caused by temperature changes, so this product does not have an oil conservator, which obviously reduces the height of the transformer.
e. Because the corrugated sheet replaces the oil conservator, the transformer oil is isolated from the outside world, which effectively prevents the entry of oxygen and moisture, which leads to a decrease in insulation performance.
f. According to the above five points of performance, it is ensured that the oil-immersed transformer does not need to be changed during normal operation, which greatly reduces the maintenance cost of the transformer and prolongs the service life of the transformer.

 

10KV S11 Oil Transformer main technical data

Rated Capacity
(KVA)
High
voltage
(KV)
Tapping
Range
Low
voltage
(KV)
Frequency
(Hz)
Connection
Symbol
No-load loss
(W)
load loss
(W)
No-load Current
(%)
Noise level
(dB)
Short-circuit
impedance (%)
Gauge
A x B
(mm x mm)
Dimensions
L*W*H (mm)
Weight (KG)
306
6.3
6.6
10
10.5
11
±5%
±2X 2. 5%
0.450
  1. yn11
  2. Y, ynO
1006302.3444400770X545X890260
501309102.044400790X560X920320
8018013101.948400850X635X980420
10020015801.848550865X685X990470
16028023101.6495501120X740X1050610
20034027301.5515501235X825X1080750
25040032001.4515501275X860X1100850
31548038301.4535501300X870X1170960
40057045201.3536601395X960X11901160
50068054101.2546601530X1080X12301340
63081062001.1544.56601660X1180X13001660
80098075001.0578201740X1255X14002100
10001150103001.0578201780X1320X14902400
12501360120000.9598201855X1345X15802850
16001640145000.8598201960X1415X17003430

 

10KV-S13/14 Oil Transformer main technical data

Rated Capacity
(KVA)
High
voltage
(KV)
Tapping
Range
Low
voltage
(KV)
Frequency
(Hz)
Connection
Symbol
No-load loss
(W)
load loss
(W)
No-load Current
(%)
Noise level
(dB)
Short-circuit
impedance (%)
Gauge
A x B
(mm x mm)

Dimensions

L*W*H (mm)

Weight (KG)
S13S14S13S14
30

6

6.3

6.6

10

10.5

11

±5%

±2X 2.5%

0.450D, yn11 Y. ynO8080630/600505/4801.4504400X40C1005X670X960280
50100100910/870730/6951.250400 X 40C1005X670X990390
801301301310/12501050/10000.9752400X40C1060 X 715X1040495
1001501501580/15001265/12000.9752550X55C1075X735X1060600
1251701701890/18001510/14400.8454550X55C1110X750X1100690
1602002002310/22001850/17600.8454550X55C1140X780X1130780
2002402402730/26002185/20800.7456550X55C1210X815X1150908
2502902903200/3052560/24400.6456550X55C1290X885X11901043
3153403403830/36503065/29200.6458550X55C1300X880X12301190
4004104104520/43003615/34400.5458660 X 66C1410X975X13001430
5004804805410/51504330/41200.5460660X66C1465 X 980X13901648
630570570620049600.54604.5660X66C1560X1050X14102027
800700700750060000.4862820X82C1700X1160X14802500
10008308301030082400.4262820X82C1790X1280X15202700
12509709701200096000.3665820X82C1890X1360X16003280
16001170117014500116000.3669820X82C1970X1430X1700

3500

Hot Products

KYN28A-12KV for 6KV withdrawable switchgear Voltage: 12KV Current:630-2000A Circuit breaker: Vacuum ...
Withdrawable vacuum circuit breaker for medium voltage use KYN28A-12 Voltage: 12KV Current: 630...
Withdrawable VCB medium voltage switch panel KYN28A-12 metal-clad type Voltage: 3.6-24KV Current: ...
IEC GB standard 12KV 1250A KYN28 metal-enclosed switchgear for power plants use Voltage: 3.6KV-24KV...
KYN28A-12KV medium voltage 3.6KV 6.6KV 12KV 24KV withdrawable switchgear Voltage: 12KV Current:630...
Vacuum circuit breaker type switchgear KYN28 for medium voltage using Voltage: 3.6KV 6.6KV 12KV 24KV ...