Home Companies Knkong Electric Co.,Ltd

Solar Powered JYW-KK IPX7 Overhead Line Fault Indicator Automatic Warning

Knkong Electric Co.,Ltd
Active Member

Contact Us

[China] country

Address: No. 25 Street , Hanghai Road, Zhengzhou,Henan,China

Contact name:Ken Chan (English)

Inquir Now

Knkong Electric Co.,Ltd

Solar Powered JYW-KK IPX7 Overhead Line Fault Indicator Automatic Warning

Country/Region china
City & Province zhengzhou henan
Categories Other Chargers
InquireNow

Product Details

Solar Powered JYW-KK IPX7 Overhead Line Fault Indicator Automatic Warning

 

Product Introduction

 

 

1. Advantages
Be the first to apply Roche coils into this type of indicator, It has great linearity of test data and is not affected by wire diameter, thus guarantee test accuracy;
The "energy module" which use the anti-corrosion and high-permeability material with low-power system design enables the battery-free full-function operation at a primary current of 2A;
The three-level power architecture (CT power supply, supercapacitor, and disposable lithium battery) constitutes the power supply system let the equipment operates 24/7;
High-protection level "collection unit", withstands temperature shocks and long-term blisters, ensuring long-term outdoor working reliability;
Both the collection unit and the acquisition unit can be controlled remotely and wirelessly;

 

2. Technical Parameter

ItemParameter

 

Applications

Voltage6~35kV
Neutral grounding methodVarious grounding methods are available
Wiring typeOverhead insulation and bare wires 35mm²~240mm²

 

Collection unit power supply

Main power

Solar power supply (the rated output voltage of the solar panel is 18V, and the capacity is based on

necessary)

Backup power

Rechargeable battery: Lithium iron phosphate or lead-acid colloid battery is dependent on necessary.

All hardware design is compatible for them both.

 

Acquisition unit power supply

Main powerLine self-powered (5A full-function operation)
Backup powerDisposable lithium battery 3.6V, 8.5Ah
Time of duration of the supercapacitor battery> 12 hours
Static power dissipationAcquisition unit≤40uA
Collection unit≤0.2VA
Telemetry accuracyCurrent

0~100A, measurement accuracy:±3A

100A~600A,measurement accuracy:±2%

Fault detectionRecognizable fault typeShort circuit between phases, various single-phase grounding
Instantaneous faults and permanent faults
Recognition minimum recognition time0.2s

 

Line status indication

Indication360° omnidirectional bright LED
Flashing time after an outage>2000h
Fault reset methodA timed automatic reset can be set from 1 to 48 hours
Power-on automatic reset and remote manual reset

 

Local communication

Frequency band430~480MHz
Communication distance>50m
Transmit power consumption<25mA@+10dBm
Receive power consumption<3mA
Communication frequency150kbps
Mechanical propertiesWeight<1kg
Protection levelAcquisition unit IPX7;Collection unit IPX5
Working environmentTemperature-40℃~70℃
Humidity10%~100%
Service lifeOperating>8 years
Failure-free time (average)

MTBF≥70000h

 

 

Hot Products

KYN28A-12KV for 6KV withdrawable switchgear Voltage: 12KV Current:630-2000A Circuit breaker: Vacuum ...
Withdrawable vacuum circuit breaker for medium voltage use KYN28A-12 Voltage: 12KV Current: 630...
Withdrawable VCB medium voltage switch panel KYN28A-12 metal-clad type Voltage: 3.6-24KV Current: ...
IEC GB standard 12KV 1250A KYN28 metal-enclosed switchgear for power plants use Voltage: 3.6KV-24KV...
KYN28A-12KV medium voltage 3.6KV 6.6KV 12KV 24KV withdrawable switchgear Voltage: 12KV Current:630...
Vacuum circuit breaker type switchgear KYN28 for medium voltage using Voltage: 3.6KV 6.6KV 12KV 24KV ...