MIC500S Fixed Toxic And Harmful Gas Detector
MIC500S Series gas detector can be used in 24 hours continuous online monitoring of concentrations of multiple types of gases in the field. The types for detection are more than 500 types. With a 4-20 mA analog output, can be simply integrated into a Distributed Control System (DCS) to provide warnings.
Gas | CO2 (Carbon Dioxide) | Range | 0-50000PPM; 0-100%LEL ; 0-100%Vol. other ranges can be customized |
Size | 210×170×85mm (L×H×W) | Weight | 1.8 Kg |
Installation method | Pipeline Type Wall Mounting Type | Display | 1.7-inch high-definition color screen |
Environment | Temperature: -40 ℃ ~ + 70 ℃ Humidity: ≤10 ~ 95% RH (regular) | Approvals | IP65; Exd Ⅱ CT6 |
Accessories | Manual, qualification certificate, warranty card, outer packaging
box | ||
Working Voltage | 12 ~ 30VDC direct current, the standard power supply for a single
equipment is 24V, DC stabilized voltage switching power supply of
1A or greater than 1A | ||
Working Method | Fixed type installation, online detection, diffusion type
measurement; and it is possible to select the measurement of
pipeline type, flow-through type, and pump-suction type. | ||
Connecting Cable | Adopted 4 ~ 20mA three-core shielding cable, adopted four-core for
RS485, when the distance exceeded 100 meters, the single wire
diameter ≥1.5mm; and the shielding layer will be connected to the
earth. | ||
Optional items | Alarms;Wireless Transmission;Pretreatment System; SD Card; Temperature and Humidity Measurement; Accessory for connection with computer for monitoring. | ||
Installation Type Accessories (Optional configuration) | Wall mounting bracket, mounting clips for fixation on the pipes
(1/2", 3/4" pipe), stainless steel threaded welding seat or flange to be installed on the pipeline (it is necessary to mark the flange or pipe size, such as DN50, DN15 ...), rain cover, 24VDC or 220AC sampling pump (sampling distance is 10 m), vacuum pump (sampling distance is 40 m), 24V switching power supply, pressure reducing valve, flow meters |
1.multi-directional and three-dimensional indication alarm states.
Alarm types include: concentration alarm, and failure alarm.
Multiple alarm mode settings: low alarm, high alarm, interval
alarm, and weighted average alarm.
2. Zero-point automatic tracking; long-term use will not be
affected by the zero drift.
3. Multi-level calibration for target points, can ensure the
linearity and accuracy of the measurements.
4. Log recording Record the calibration logs, repair logs, failure
history, failure countermeasure solutions,
sensor service life due reminder, and function of reminder for the
time of next concentration calibration.
5. Data recovery function; in case of mis-operation, it is possible
to select partial or full recovery.
6. Mis-operation recognition function: automatic recognition and
prevention of the concentration calibration mis-operation,
which is possible to avoid the poor performance that may be caused
by human factors.
All the cases which requires the fixed installation, and online detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.