MIC500S Fixed Gas Detector
Infrared remote control
① Standard configuration includes the infrared remote control, it is possible for one-key operation via infrared remote control function key, which can achieve the operation without opening the cover under hazardous situations, such as: the functions like modification of the alarm point, density calibration, zeropoint calibration, noise reduction, restoring the factory setting, and so on.
Powerful and convenient humanized function
① Multiple alarm modes, and multi-directional and threedimensional indication alarm states. It includes: 2 sets of relay switch output, sound & light alarm (optional configuration), and display screen visual alarm.Alarm types include: concentration alarm, and failure alarm.Multiple alarm mode settings: low alarm, high alarm, interval alarm, and weighted average alarm.
② Zero-point automatic tracking; long-term use will not be affected by the zero drift.
③ Multi-level calibration for target points, can ensure the linearity and accuracy of the measurements.
④ Log recording Record the calibration logs, repair logs, failure history, failure countermeasure solutions, sensor service life due reminder, and function of reminder for the time of next concentration calibration.
⑤ Data recovery function; in case of mis-operation, it is possible to select partial or full recovery.
⑥ Mis-operation recognition function: automatic recognition and prevention of the concentration calibration mis-operation, which is possible to avoid the poor performance that may be caused by human factors.
Gas | NO/NO2 can be customized | Range | 0-100ppm other ranges can be customized |
Size | 210×170×85mm (L×H×W) | Weight | 1.8 Kg |
Installation method | Pipeline Type Wall Mounting Type | Display | 1.7-inch high-definition color screen |
Environment | Temperature: -40 ℃ ~ + 70 ℃ Humidity: ≤10 ~ 95% RH (regular) | Approvals | IP65; Exd Ⅱ CT6 |
Accessories | Manual, qualification certificate, warranty card, outer packaging
box | ||
Working Voltage | 12 ~ 30VDC direct current, the standard power supply for a single
equipment is 24V, DC stabilized voltage switching power supply of
1A or greater than 1A | ||
Working Method | Fixed type installation, online detection, diffusion type
measurement; and it is possible to select the measurement of
pipeline type, flow-through type, and pump-suction type. | ||
Connecting Cable | Adopted 4 ~ 20mA three-core shielding cable, adopted four-core for
RS485, when the distance exceeded 100 meters, the single wire
diameter ≥1.5mm; and the shielding layer will be connected to the
earth. | ||
Optional items | Alarms;Wireless Transmission;Pretreatment System; SD Card; Temperature and Humidity Measurement; Accessory for connection with computer for monitoring. | ||
Installation Type Accessories (Optional configuration) | Wall mounting bracket, mounting clips for fixation on the pipes
(1/2", 3/4" pipe), stainless steel threaded welding seat or flange to be installed on the pipeline (it is necessary to mark the flange or pipe size, such as DN50, DN15 ...), rain cover, 24VDC or 220AC sampling pump (sampling distance is 10 m), vacuum pump (sampling distance is 40 m), 24V switching power supply, pressure reducing valve, flow meters |
Gases to be detected | Range | Accurancy | Resolution | Response time T90 |
Oxygen gas ( O2 ) | 0-30%Vol | <±2%(F.S) | 0.01%Vol | ≤10 seconds |
Nitrogen oxide ( NOX ) | 0-100ppm | <±2%(F.S) | 0.01ppm | ≤30 seconds |
Chlorine gas ( CL2 ) | 0-10ppm | <±2%(F.S) | 0.001ppm | ≤30 seconds |
Ammonia gas ( NH3 ) | 0-100ppm | <±2%(F.S) | 0.01ppm | ≤30 seconds |
Hydrogen gas ( H2 ) | 0-40000ppm | <±2%(F.S) | 1ppm | ≤30 seconds |
Nitrogen gas ( N2 ) | 0-100%Vol | <±2%(F.S) | 0.01%Vol | ≤10 seconds |
Carbon monoxide ( CO ) | 0-100ppm | <±2%(F.S) | 0.1ppm | ≤25 seconds |
Carbon dioxide ( CO2 ) | 0-100%Vol | <±2%(F.S) | 0.01%Vol | ≤30 seconds |
Formaldehyde ( CH2O ) | 0-100ppm | <±2%(F.S) | 0.01ppm | ≤30 seconds |
Ozone ( O3 ) | 0-100ppm | <±2%(F.S) | 0.01ppm | ≤20 seconds |