Product Details

MS104K Portable Muiti Combustible Gas Detector

 

OVERVIEW

 

Data recovery function; in case of mis-operation, it is possible to select partial or full recovery. It is possible to set whether to display the maximum value, minimum value, average value or not. Standard USB charging port, with charging protection function, USB hot-plug supported,and the charging status instrument can work properly. 2100mA high capacity rechargeable polymer battery is adopted, so it is possible to work for a long period of time.

Zero-point automatic tracking; long-term use will not be affected by the zero drift. Multi-level calibration for target points, can ensure the linearity and accuracy of the measurements.
 

 

FEATURES

 

1. Multi-gas made simple, easy to wear, slim and compact
It is possible to simultaneously detect 1 ~ 4 types of gases, and the units can be switched freely .
Units that can be selected: PPM, mg/m3, Vol%, LEL%, PPHM, ppb, mg/l.


2. Compact design, easy to use
Handy and durable, the MS104 is intuitive to operate single-handedly using three function keys.
The easy-to-read color display clearly lays out all the information for you. Thanks to its compact and robust construction, the device can withstand even the harshest conditions.

3. Large Data Storage Management, release and documentation in no time
Standard configuration is the data storage capacity for 100, 000 entries.
Real-time storage and fixed time storage are supported, or only the data of the alarm concentration will be stored.
It is supported to use the local host to view, and delete data, and upload the data via USB interface to the computer for data analysis or printing.RS485 communication is an optional configuration.

4. Clear signaling design
The signal system of the MS104K is based on a clear color code: sound & light alarm, vibration alarm, display screen visual alarm.These are also documented in the data logger.

5. Economical Calibration Management
The deviation of the concentration which was detected out by the instrument from the standard gas concentration can be corrected by calibrating the concentration or changing the display coefficients.

6. Inductive charging protects against wear and tear
The MS104K features inductive charging.
This makes it easier to operate and increases the lifespan of the device.
Issues like corrosion and contact problems in the charging cradle are a thing of the past. You can charge (outside of explosion-hazard zones) and measure at the same time.

 

SPECIFICATION

 

Gases to be detected
Arbitrary combination of 1 ~ 4 types of gases such as toxic gases, oxygen gas, carbon dioxide, inflammable and explosive gases, TVOC, and so on. Optional configuration: temperature and humidity measurements.
Application scenarios
All the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.
Detection range
0 ~ 1, 10, 100, 1000, 5000, 50000, 100000ppm, 200 mg/L, 100%LEL, 20%, 50%, 100%Vol, can be selected; and other ranges can be customized.
Resolution
0.01ppm or 0.001ppm (0 ~ 10 ppm);
0.01ppm (0 ~ 100 ppm),
0.1ppm (0 ~ 1000 ppm),
1ppm (0 ~ 10000 ppm or more),
0.01 mg/l (0 ~ 200 mg/l),
0.1% LEL,
0.01%,
0.001% Vol
Detection principle
Electrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, and so on, depending on the type of gas, range, field environment and user demand.
Sensor service life
Electrochemical principle: 2 ~ 3 years; Oxygen gas: 2 years or 6 years can be selected; infrared principle: 5 ~ 10 years;
catalytic combustion: 3 years; thermal conductivity: 5 years; PID photoionization: 2 ~ 3 years.
Allowable error
≤±3% F.S (higher precision levels can be customized)
Linearity
≤±2%
Repeatability
≤±2%
Uncertainty
≤±2%
Response time
T90≤30 seconds
Recovery time
≤30 seconds
Working environment
Temperature: -40 ℃ ~ + 70 ℃, humidity: ≤10 ~ 95% RH
Sample gas temperature
-40 ℃ ~ + 70 ℃, and the optional configuration of high-temperature sampling and cooling filter handle will be possible to detect
the smoke gas at the temperature of 400 ℃ or higher.
Temperature and humidity measurement
Optional configuration: temperature at -40 ℃ ~ + 70 ℃, accuracy level at 0.5 ℃; humidity at 0 ~ 100% RH, precision level at 3 % RH
Power supply
3.7VDC, 3000mA high capacity rechargeable polymer battery
Display mode
2.31-inch high-definition color screen
Detection mode
Diffusion type measurement. The calibrated flow rate is 500 ml/minute.
Alarm mode
It is possible to set as sound & light alarm, vibration alarm, sound & light + vibration alarm, turning off the alarm.
Communication interface
USB (charging and communication), optional: RS485 communication interface
Data storage
Standard configuration is the data storage capacity for 100, 000 entries
Protection level
IP65
Explosion-proof type
Intrinsically safe type
Explosion-proof mark
Exia II CT4 Ga
Exterior dimensions
130×68×34mm (L×W×H)
Weight
200g
Standard accessories
Manual, qualification certificate, warranty card, USB charger (including the data cable), belt clip, colorful packaging box (optional high-grade aluminum instrument case)
Optional items
Temperature and humidity measurement function, external gas sampling pump, 1.2 m retractable sampling handle (1-10 meter hose, and
the standard length is 1 meter), 0.4 meter stainless steel sampling handle (with dust filter, not retractable)

 

APPLICATION

 

The detector is widely used in petroleum, chemical industry,environmental protection, metallurgy, refining, gas, biochemical medicine, agriculture, fire protection, Archaeology and other industries and places that need safety monitoring for toxicity and harmfulness, explosion prevention. 

 

 

Hot Products

AT 7000 Portable Alcohol Detector OVERVIEW AT7000 is a newly developed alcohol tester with rapid ...
AT 7200 Portable Alcohol Detector OVERVIEW AT7200 is a newly developed alcohol tester with rapid ...
AT 7200 Portable Alcohol Detector OVERVIEW AT7200 is a newly developed alcohol tester with rapid ...
MS104K-S1​ Protable Single Gas Detector OVERVIEW MS104K-S1 is a maintenance-free single gas detector...
MS104K-S1​ Personal Safety Gas Detector OVERVIEW The most dependable, affordable, and user-friendly ...
MS104K-S1​ Protable Single Gas Detector OVERVIEW MS104K-S1 is a maintenance-free single gas detector...