SG600 Solar pumps inverter MPPT solar pump controller , 220V/380V solar pump drive

The SG600 series solar pump inverters is a low voltage pumps inverter of 0.3 to 400KW above rating designed to operate with energy drawn from solar panel or photovoltaic cells (PV).

The inverters is customized to operate in dual supply mode (Ac and DC), so the grid connected supply is used in the absence of energy from PV cells. This drive functions with the latest in technology maximum power point tracking (MPPT) algorithm to derive maximum power from the PV cells at any instant.

SG600 solar pump inverter features.

The SG600 series solar pump inverter is a low voltage AC drive of 0.3 to 400KW above rating designed to operate with energy drawn from solar panel or photovoltaic cells (PV).

The inverter is customized to operate in dual supply mode (AC and DC), so the grid connected supply is used in the absence of energy from PV cells. This inverters functions with the latest in technology maximum power point tracking (MPPT) algorithm to derive maximum power from the PV cells at any instant.

  • Maximum power point tracking (MPPT) with fast response speed and stable operation efficiency > 99.6%;
  • High speed running when sunlight radiation is good, frequency reduce fast when sunlight is become weak, stop running when output frequency lower lower limit frequency setting.
  • Suits for most 3 phase AC pumps and AC PMSM high efficiency pumps.
  • The working voltage of solar panel can set by manual or MPPT automatically tracking
  • Compatible with dual power input, AC grid and DC power supply input.
  • Built in automatic sleep-wake up function, start by timer is option.
  • Dry run (under load ) protection
  • Motor maximum current protection
  • Low input power protection
  • Lowest stop frequency protection
  • The PQ (power/flow) performance curve enables calculating the flow output from the pump
  • Digital control for fully automatic operation, data storage and protective functions
  • Intelligent power module (IPM) for the main circuit
  • LED display operating panel and support remote control
  • Low water probe sensor, and water level control function
  • Strong lightning protection
  • Easy operation and CVT auto detection function
  • GPRS function is option for remote start and stop, remote parameters setting.

 Solar pump inverter models and specification

NModelsRate currentOutput voltage ( 3PH VAC)Applicable for pumpsMPPT voltage (VDC)
Mini type 2S series : 90/150 to 450 VDC or 220VAC input,Vmp 310V, Voc 380V
1SG600-0K7GB-2S-M3.8A0-220VAC0.75KW260 to 375
2SG600-1K5GB-2S-M7A0-220VAC1.5KW260 to 375
3SG600-2K2GB-2S-M10A0-220VAC2.2kw260 to 375
4SG600-4K0GB-2S17A0-220VAC4.0KW260 to 375
General type: 4T, 250/350 to 800 VDC or 380VAC input, Vmp520, Voc650
1SG600-0K7GB-4T2.3A0-380V0.75KW486 to 750
2SG600-1K5GB-4T3.8A0-380V1.5KW486 to 750
3SG600-2K2GB-4T5.1A0-380V2.2KW486 to 750
4SG600-4K0GB-4T10A0-380V4.0KW486 to 750
5SG600-5K5GB-4T13A0-380V5.5KW486 to 750
6SG600-7K5GB-4T17A0-380V7.5KW486 to 750
7SG600-011GB-4T25A0-380V11KW486 to 750
8SG600-015GB-4T32A0-380V15KW486 to 750
9SG600-018GB-4T37A0-380V18KW486 to 750
10SG600-022GB-4T45A0-380V22KW486 to 750
11SG600-030G-4T60A0-380V30KW486 to 750
12SG600-037G-4T75A0-380V37KW486 to 750
13SG600-045G-4T91A0-380V45KW486 to 750
14SG600-055G-4T110A0-380V55KW486 to 750
15SG600-075G-4T150A0-380V75KW486 to 750
16SG600-090G-4T180A0-380V90KW486 to 750
17SG600-110G-4T220A0-380V110KW486 to 750
18SG600-132G-4T260A0-380V132KW486 to 750
19SG600-160G-4T320A0-380V160kw486 to 750
20SG600-185G-4T377A0-380V185kw486 to 750
21SG600-200G-4T426A0-380V200kw486 to 750
22SG600-220G-4T465A0-380V220kw486 to 750
23SG600-250G-4T465A0-380V250kw486 to 750
24SG600-280G-4T520A0-380V280kw486 to 750
25SG600-315G-4T585A0-380V315kw486 to 750
26SG600-355G-4T650A0-380V355kw486 to 750
27SG600-400G-4T725A0-380V400kw486 to 750

 

Solar pump inverter technical specification

**Solar pump inverter specification when PE-00=1&2
Recommended MPPT voltage range

Vmp 131 to 350 VDC for 1s 3 phase 110VAC pumps

Vmp 260 to 355VDC for 2S 3 phase 220VAc pumps

Vmp 486 to 650 VDC for 4T 3 phase 380VAc pums

Recommended input Voc and Vmpp voltage

Voc 180(VDC), Vmpp 155(VDC) for 1S model or 110V AC pumps

Voc 380(VDC), Vmpp 310(VDC) for 2S model or 220V AC pumps

Voc 650(VDC), Vmpp 520(VDC) for 4T model or 380V AC pumps

Voc 820(VDC), Vmpp 676(VDC) for 5T model or 480V AC pumps

Motor typeControl for permanent magnet synchronous motor and asynchronous motor pumps.
Rated output voltage1/3-Phase,110V/160V/220V. 3-phase, 220V/380V/460V
Output frequency range0~maximum frequency 600Hz.
MPPT efficiencyAbove 99.6%,
Ambient temperature range

G-type for submersible pumps, 150% rated current for 60s, 180% rated current for 2s .

P type for general pumps, 120% rated current for 60s, 150% rated current for 2s

Solar pump control special performanceMPPT ( maximum power point tracking), CVT (constant voltage tracking), auto/manual operation, dry run protection, low stop frequency protection, minimum power input, motor maximum current protection, flow calculating, energy generated calculating and water tank level detected
Protection functionPhase loss protection, phase short circuit protection, ground to phase circuit protection , input and output short circuit protection. Stall protection, lightning protection
Protection degreeIP20, Air force cooling
Running modeMPPT or CVT
AltitudeBelow 1000m; above 1000m, derated 1% for every additional 100m.
Enhanced version of AC driveCE, Design based on vector control motor AC drive, more specification please refer to S600 or S600 vector control drive operation manual

Solar pump inverter comissioning

It is accepted dual power AC/DC mode connecting input. If connect AC and DC at the same time, please install a anti direction diode (protection diode) between inverter and soalr panels which used to protection solar panels safety.

User can able to install a power switchover to selection which mode power input as conditions.

 

 

 

1. Wiring DC power supply to R, T terminals of inverter. ( or connect P P- termianls as well) 

2.Check actual Voc ( open loop circuit voltage) of solar arrays by multi-meter, or monitor U012 parameters that display Voc value in keypad. Set PE-03 with actual Voc value.

3.Confirmed PE-00 if set for 1or 2 for MPPT working in solar pump control model.

4. Set P1-00 to P1-05 motor group parameters for getting better pumps protection.

5. Press the RUN button to start inverter (keypad control mode is in default setting, P0-02=0),to check output frequency, output voltage if good or not. The output frequency should be increase from 0 to 50/60hz, and output voltage should be balanced when frequency reach to rated frequency of pumps.

6.If output frequency and output voltage is normal, please stop inverter, and then switch off power, after that connect pump to U, V, W of inverter. ( connect U, W for 1 phase pumps).

7. Press the RUN to start inverter to check water flow if correct, if water flow is small when reach to high speed, please check the pump running direction if correct or not. Please rewire any two phase order of U, V, W if pump running direction is not correct.

Solar panels selection 

Voc and Vmp selecting er pumps voltage. 

Input voltage, power solar arrays selection
Pumps modelInverte modelsVmpVocTotal Power of solar arrays
110VAC pumps1S110*1.41=155VDC190VDC

≧ (1.3 to 2.0) rated power of pumps

It is also depend on the quality of solar panels. The more power input, the better performance.

220VAC pumps2S220*1.41=310VDC372VDC
380VAC pumps4T (Max 800VDC)380*1.41=540VDC648VDC
480VAC pumps4T ( Max 900VDC)480*1.41=677VDC812VDC

Solar arrays selection tables as AC pumps.

Connecting solar panels in series to get enough voltage input, and then calculating how much strings for getting enough power.

Take a solar panels Voc38VDC, Vmp 31VDC, 265W for exampling.

Please check if enough DC voltage input for system, Voc and Vmp. 2S (310vmp), 380V (540vmp).

If the output frequency is not high, lower than 50/60Hz even in good sunlight radiation, please check if enough solar panels have been connected. The total power should be at least bigger 1.3 times than of rated power of pumps.

Solar panel spec.:265w, 38Voc (Open circuit voltage), 31Vmp ( Voltage at Pmax)
Inverter modelsPower of pumpConnection in series (PCS) (Vmp)Connect in parallel ( Strings) PowerTotal (PCS)
1S (110VAC)0.75kw to 1.0kw4 or 5 PCS1* strings5*1=5
2S (220VAC)0.75kw to 1.5kw10PCS1* strings10*1=10
2S (220VAC), Max 450vdc2.2kw11PCS1* strings11*1=11
4T(380VAC)0.75kw to 2.2kw18PCS1* strings18*1=18

4T(380VAC)

Max 900VDC

3.7kw20PCS1* strings20*1=20
4T(380VAC)5.5kw18PCS2* strings18*2=36

4T(380VAC)

Max 900VDC

7.5kw20pcs2* strings20*2=40
4T(380VAC)11kw18pcs3* strings18*3=54

4T(380VAC)

Max900VDC

15kw20pcs4* strings20*4=80

 

 

 

Hot Products

SG200 380V 0.75k to 5.5kw series solar pump inverter compatible with dual supply mode The solar pump ...
IP54 IP65 Solar Pump Inverter DC Voltage Pumps Drive Solar Pump VFD With MPPT SD600-IP65 series ...
SG320 220V Solar Pump Inverter For IM And PMSM AC Pumps Control MPPT Gprs Remotor Control 1 Phase ...
220V Input 380V Output Motor VFD Motor AC Drive Pumps Frequency Inverter Fans Variable Speed Drive ...
SG600 Solar pumps inverter MPPT solar pump controller , 220V/380V solar pump drive The SG600 series ...
ZK/ZUN Solar VFD 0.75kw 2.2kw 450VDC 220VAC LED Keypad MPPT Vfd Solar Pump Inverter SU10M-D2-2R2G-B ...