Customized Yc1891d-6 Single Phase Meter Test Bench for Industrial Applications

 

Product Description

 

  • Meters under testing: 1P2W
  • Testing mode active power, reactive power With MSVT, can test single phase meters with closed links between the current and voltage measuring circuits(I-P links) With current output switch, can calibrate 2-element meters (optional)
  • Installing Rs232 Ethernet communication ports in each meter position, to realize automatic calibration of electronic meters  (optional)  
  • The meter test systems can measure mechanical meters, electronic mechanical meters and electronic meters by the way of automatic, semi-automatic or manual operation
  • Aluminum alloy material, light and strong and corrosion resistant
  • Automatic positioning rotor mark of disc of mechanical meters, with more efficiency.
  • The swing together of the scanning heads simplifies the control
  • Starting test and creeping test
  • Measuring different constants of meters synchronously
  • With the protection function of overload, short voltage circuit and open current circuit
  • The testing software with friendly Window 10 and XP operation system, includes functional module of all kinds or modern energy meter needed, to reality error test, harmonic test, demand test, influence test etc.
  • The stored testing data can be transferred to multi-format for other program use
  • The whole system is accredited to conforms to EU health and safety standards with CE certificate

 

Product Parameters

 

 

 YC1891D-6YC1891D-12YC1891D-24YC1891D-48
Number of meter positions6122448
Accuracy0.05
Power SourceYCS-101-250YCS-101-600YCS-101-1200YCS-101-2500
Standard MeterSZ01A-K3
MSVTHJ200GL-6HJ200GL-12HJ200GL-24HJ200GL-48
QCDD5 series
Scanning HeadYCG-2 series
Voltage
Test voltage output24V – 288V or customized
Power of the voltage output100VA250VA500VA1000VA
ResolutionBetter than 0.01% of full scale value of range
Setting accuracyBetter than 0.05% at the final range value
StabilityBetter than 0.005%/h (integration time 150 s)
Load regulation from 0-max. loadBetter than 0.01%
Distortion factorBetter than 0.3% for linear resistance load
Harmonics2nd – 21st free programmable
Current
Test current output1mA – 100A or customized,Max.200A1mA – 100A
Power of the current output150VA350VA750VA1500VA
ResolutionBetter than 0.01% of full scale value of range
Setting accuracyBetter than 0.05% at the final range value
StabilityBetter than 0.005%/h (integration time 150 s)
Load regulation from 0-max. loadBetter than 0.01%
Distortion factorBetter than 0.3% for linear resistance load
Harmonics2nd – 21st free programmable
Phase angle
Range0 -- 360°
Resolution0.01°
Setting accuracy0.1°
Frequency
Range45Hz – 65Hz
Resolution0.01Hz
Error display
Type of error displayRed LED
Resolution of the error displays8 digits
 
Voltage Supply

220V±10% or customized

50/60Hz±2Hz

3x220/380V±10% or customized

50/60Hz±2Hz

Ambient temperature-10°C -- +40°C
Relative humidity35% -- 85%

 

Applications

 

 

1. Nation-level utility companies

2. Governmental bureaus of metrology

3. Big energy meter manufacturers

 

Primary Competitive Advantages

 

 

1. High quality product

2. Over 18 months long warranty

3. High accuracy class: 0.05/0.02
*** highest accuracy can reaches to 0.01% under 3 meter positions***

4. 3~48 Single Phase Electric Energy Meter Test bench

5. Extremely high power stability

6. Neutral current test(optional)

7. Timing error test

8. Influence test of voltage, frequency, and harmonic

9. Installing RS232, Ethernet communication port in each meter position.

10. Tilt impact test (optional)

 

 

 

 

*If you want to know more please check our official website:http://www.genymetertestequipment.com/

Hot Products

Stationary Meter Test System with 0.01 Class Accuracy and Optional Standard Meter YC-1893R series of ...
Intelligent Energy Meter Calibration Device for Single-Phase Meters Stationary Meter Test System ...
High-Precision Stationary Meter Test System with Output for Voltage and Current Specification ...
Three-Phase Intelligent Electricity Meter Calibration Device Stationary Meter Test System The YC...
Versatile Stationary Meter Test System for Electromechanical Meters The YC-1893D series three-phase ...
YC-1893R High-grade Three-phase Energy Meter Calibration Device The YC-1893R series of three-phase ...