Theory Portable Three Phase Electronic Meter with Terminal Power Meter Connection

Product Description

The YC98G is a portable working standard meter with human oriented design to verify active / reactive three phase meter (3 or 4 wires) and single-phase meter, which accuracy class from 0.1 to 0.05, suitable for field testing.

  • One phase two wire
  • Three phase four wire
  • Three phase three wire
  • Highlights
  1. Measuring mode: gives information about the parameters of the line under test, like:
    • Phase voltage, current, angle
    • Active power, reactive power, apparent power.
    • Phase and three-phase power factor.
    • Phase angle of phase to phase voltage
    • Phase angle of phase to phase current
    • Frequency.
  2. Vector diagram: draw the line vector diagram
  3. Waveform: show the wave form of voltage and current
  4. Harmonics: make a graphic and numeric analysis of the THD. (2nd~51st)
  5. Meters test: Performs the test to the meters. The data field configurable in this function is the serial number, the meter type, the constant, the divisor factor (for HF), the type of test and cycles.
  6. CT ratio test: get CT ratio by synchronously testing primary and secondary current of CT
  7. Wiring check: judge the wiring right or wrong automatically
  8. Energy accumulating: accumulate active and reactive energy in a setting time, used for meter's dial test
  9. Clamp CT self-calibration: check whether the clamp CT is accurate and re-calibration.
  10. Test data storage: can store 1000 data groups. Data include meter type, serial number, constant, error, date etc.
  11. It has a RS232 interface to communication with a PC
  12. Firmware can be upgraded through PC by users themselves
  13. Can connect with external printer, keyboard, barcode scanner
  14. In dial test, user can input active, reactive, apparent energy, and calculate three kinds of energy error: active, reactive, apparent.
  15. Pulse and manual switch and key control can be used to check the pulsing error.

Product Parameters

  • Specification for YC98G - 0.1%
emMeasurement rangeEffective resolutionAccuracy (%)Others
voltage5 - 450 V0.001 V0.05%2 ranges(1:4)
Current CT0.05 - 20 A0.0002 A0.05%3 ranges(1:10)
Clamp CT0.01 - 100 A0.001 A0.15%3 ranges(1:10)
frequency45-65 Hz0.001 Hz0.01 Hz 
Active power0~±Umax X Imax0.0001 W0.10% 
 0~±Umax X Imax0.0001 W0.20%With CT Clamp
Reactive power0~±Umax X Imax0.0001 Var0.20% 
 0~±Umax X Imax0.0001 Var0.30%With CT clamp
Apparent power0~±Umax X Imax0.0001 VA0.20% 
Active energy  0.10% 
   0.20%With CT clamp
Reactive energy  0.20% 
   0.30%With CT clamp
Energy Constant180000imp/kWh / 1800imp/kWh / 18imp/kWh* 
Power Factor0~±0.99990.0001±0.01 
Phase angle0 ~ 359. 999º0.001 º±0.01 º 
Working environment-10~+55ºC, 15~85% RHD,altitude:-10~3500 m 
Temperature Influence≤25ppm/ºC(U/I, ≤15ppm /ºC(others) 
Frequency Influence≤25ppm / Hz 
Pulse interfaceInput (2 channels, PLi1, PLi2) 
Low level≤2V, high level≥5V
Output (2 channels, PLo-1 active power, PLo-3 reactive power)
Low level≤0.5V, high level≥11.5V
 
Communication interfaceAsynchronous serial transmission: RS232, 9600bps, 1N8. 
Power supply1Power from U1, Un tested circuit terminals: 85~450V/≯35VAFrom tested circuit
Power supply 2Power from the AC socket: 85~450V/≯35VA 
Power supply3Battery type: Li polymer batter, size: 110mmX51mmX16mm,Inner Li-battery
Nominate output voltage: 7.2V, Capacity: 5000mAh
DimensionInstrument: 245mm X 162mm X 60mm 
 Carry case: 559mm X 351mm X 229mm 
WeightWeight of the main instrument: 1.7kg 
 Total set weight: 11.5kg 
     
Specification for YC98G - 0.05%    
     
ItemMeasurement rangeEffective resolutionAccuracy (%)Others
voltage5 - 450 V0.001 V0.02%2 ranges(1:4)
Current CT0.05 - 20 A0.0002 A0.02%3 ranges(1:10)
Clamp CT0.01 - 100 A0.001 A0.15%3 ranges(1:10)
frequency45-65 Hz0.001 Hz0.01 Hz 
Active power0~±Umax X Imax0.0001 W0.05% 
 0~±Umax X Imax0.0001 W0.20%With CT Clamp
Reactive power0~±Umax X Imax0.0001 Var0.10% 
 0~±Umax X Imax0.0001 Var0.30%With CT clamp
Apparent power0~±Umax X Imax0.0001 VA0.10% 
Active energy  0.05% 
   0.20%With CT clamp
Reactive energy  0.10% 
   0.30%With CT clamp
Energy Constant180000imp/kWh / 1800imp/kWh / 18imp/kWh* 
Power Factor0~±0.99990.0001±0.005% 
Phase angle0 ~ 359. 999º0.001 º±0.005 º 
Working environment-10~+55ºC, 15~85% RHD,altitude:-10~3500 m 
Temperature Influence≤10 ppm/ºC(U/I, ≤ 15 ppm /ºC(others) 
Frequency Influence≤20 ppm / Hz 
Pulse interfaceInput (2 channels, PLi1, PLi2) 
Low level≤2V, high level≥5V
Output (2 channels, PLo-1 active power, PLo-3 reactive power)
Low level≤0.5V, high level≥11.5V
 
Communication interfaceAsynchronous serial transmission: RS232, 9600bps, 1N8. 
Power supply1Power from U1, Un tested circuit terminals: 85~450V/≯35VAFrom tested circuit
Power supply 2Power from the AC socket: 85~450V/≯35VA 
Power supply3Battery type: Li polymer batter, size: 110mmX51mmX16mm,Inner Li-battery
Nominate output voltage: 7.2V, Capacity: 5000mAh
DimensionInstrument: 245mm X 162mm X 60mm 
 Carry case: 559mm X 351mm X 229mm 
WeightWeight of the main instrument: 1.7kg 
 Total set weight: 11.5kg 

 

  • Specification for YC98G - 0.05%

ItemMeasurement rangeEffective resolutionAccuracy (%)Others
voltage5 - 450 V0.001 V0.02%2 ranges(1:4)
Current CT0.05 - 20 A0.0002 A0.02%3 ranges(1:10)
Clamp CT0.01 - 100 A0.001 A0.15%3 ranges(1:10)
frequency45-65 Hz0.001 Hz0.01 Hz 
Active power0~±Umax X Imax0.0001 W0.05% 
 0~±Umax X Imax0.0001 W0.20%With CT Clamp
Reactive power0~±Umax X Imax0.0001 Var0.10% 
 0~±Umax X Imax0.0001 Var0.30%With CT clamp
Apparent power0~±Umax X Imax0.0001 VA0.10% 
Active energy  0.05% 
   0.20%With CT clamp
Reactive energy  0.10% 
   0.30%With CT clamp
Energy Constant180000imp/kWh / 1800imp/kWh / 18imp/kWh* 
Power Factor0~±0.99990.0001±0.005% 
Phase angle0 ~ 359. 999º0.001 º±0.005 º 
Working environment-10~+55ºC, 15~85% RHD,altitude:-10~3500 m 
Temperature Influence≤10 ppm/ºC(U/I, ≤ 15 ppm /ºC(others) 
Frequency Influence≤20 ppm / Hz 
Pulse interfaceInput (2 channels, PLi1, PLi2) 
Low level≤2V, high level≥5V
Output (2 channels, PLo-1 active power, PLo-3 reactive power)
Low level≤0.5V, high level≥11.5V
 
Communication interfaceAsynchronous serial transmission: RS232, 9600bps, 1N8. 
Power supply1Power from U1, Un tested circuit terminals: 85~450V/≯35VAFrom tested circuit
Power supply 2Power from the AC socket: 85~450V/≯35VA 
Power supply3Battery type: Li polymer batter, size: 110mmX51mmX16mm,Inner Li-battery
Nominate output voltage: 7.2V, Capacity: 5000mAh
DimensionInstrument: 245mm X 162mm X 60mm 
 Carry case: 559mm X 351mm X 229mm 
WeightWeight of the main instrument: 1.7kg 
 Total set weight: 11.5kg 
     

 

Hot Products

All-in-One Power Solution Stationary Power Source with High Precision Stability Specifications ...
Single Phase Portable Meter Tester for Calibration with High Precision within Voltage Range10v – ...
High PrecisionPortable 3 Phase Portable Reference Standard for Single Phase Meter Calibration with ...
Highly Versatile Portable Reference Standard for All Your Testing Needs Specification Application ...
YCCl-9901 Phase and Feeder Identifier for Transformer Test Equipment 1.Phase and Feeder Identifier ...
Solid Structure Quick Connection Device for Single Phase And Three Phase Energy Meter with Pure ...