For biological laboratories 100 level protection Class II B2 Biosafety Cabinet

Class II B2 Biosafety Cabinet Features:

1. Stainless steel operating area. Corrosion resistant, easy to clean, and equipped with a power socket.

2. LED lighting system. The lighting system design, equipped with LED tubes, can effectively disinfect the products in the work area.

3. Spring-loaded sliding door up and down. All windows can be opened and closed, and can be stopped at any height, so as to facilitate the entry and exit of the experimental equipment.

4. Electric front window.

5. Automatic wind speed, with filter block.

6. The side and back walls are made of a single piece of stainless steel.

7. Interlocking function: ultraviolet lamp and front window; ultraviolet lamp and blower, fluorescent lamp; blower and front window.

8. Lean forward 10°, which can provide the operator with a sense of comfort when working for a long time, reduce glare and extend into the work area to the greatest extent.

 

ModelBHC-1000B2
Clean GradeHEPA:ISO 5 calss ( Class100 )
ULPA:ISO 4 Class ( Class10 )
HEPA FilterHEPA:≥99.995% , @0.3μm
ULPA:≥99.999% , @0.12μm
Air tightness99.99≤E≤99.999
Overall Dimensions1500×750×1950
MM
Working Space1300×650×580
MM
Inside of the door0.38±0.025m/s
Front inflow air0.48±0.025m/s

 

Maintenance of Class II B2 Biosafety Cabinet:

In order to ensure the safety of the biological safety cabinet, the safety cabinet should be maintained and maintained regularly:

1.  The working area of ​​the safety cabinet should be cleaned and disinfected before and after each use.

2.  After the service life of the HEPA filter expires, it should be replaced by a professional who has received special training in biological safety cabinets.

3.  The laboratory biosafety manual promulgated by WHO, the U.S. biosafety cabinet standard NSF49 and the China Food and Drug Administration biosafety cabinet standard YY0569 all require one of the following conditions, the biosafety cabinet should be safety tested: installation is completed and put into use Before; annual routine inspection; when the safety cabinet is shifted; after replacing the HEPA filter and repairing internal components.

Safety inspection includes the following aspects:

1.  Inlet flow direction and wind speed detection: Inlet flow direction is detected on the working section by smoke method or wire method. The detection position includes the periphery and middle area of ​​the working window; the wind speed of the intake flow is measured by an anemometer.

2.  Detecting the wind speed and uniformity of the sinking airflow: Use an anemometer to measure the wind speed of the cross section evenly.

3.  Work area cleanliness detection: use dust particle timer to detect in the work area.

4.  Noise detection: The horizontal center of the front panel of the biological safety cabinet is 300mm outwards and 380mm above the work surface to measure the noise with the sound level.

5.  Illumination detection: set a measuring point every 30cm along the center line of the length of the worktable.

6.  Leakage detection of the cabinet: Seal the safety cabinet and pressurize it to 500Pa. After 30 minutes, connect a pressure gauge or pressure sensor system in the test area to detect with the pressure attenuation method, or detect with the soap bubble method.

 

                  

 

Hot Products

TG16MW Normal Temperature Desktop No Noise High Speed Centrifuge TG16MW High Speed Centrifuge: It is ...
TG16MW High Speed Centrifuge: It is widely used in experiments with small sample volume, many steps, ...
TG16MW Safe Ultra-Quiet Research Use High Speed Refrigerated Centrifuge The high speed refrigerated ...
20800r/Min Lab High Speed Centrifuge Machine Continuous Run High Speed Centrifuge Machine Features: ...
12000r/Min High Speed Refrigerated Centrifuge All Steel Body Features of High Speed Refrigerated ...
TG16MW Normal Temperature Desktop No Noise High Speed Centrifuge TG16MW High Speed Centrifuge: It is ...