Home Companies Shenzhen Kangnuoxin Electronic Technology Co.,Ltd

ODM 9 Pin Oximax Disposable Spo2 Sensor For N560 N600

Shenzhen Kangnuoxin Electronic Technology Co.,Ltd
Active Member

Contact Us

[China] country

Address: Floor 7, C building , No. 142, Xiangshan Road,Luotian street, Bao'an district, Shenzhen

Contact name:

Inquir Now

Shenzhen Kangnuoxin Electronic Technology Co.,Ltd

ODM 9 Pin Oximax Disposable Spo2 Sensor For N560 N600

Country/Region china
City & Province shenzhen
InquireNow

Product Details

ODM 9 Pin Oximax Disposable Spo2 Sensor For N560 N600

 

9pin Oximax Disposable Spo2 Sensor For N-560 N-600

 

Product Details

Compatible

: N-560, N-600, N-600x, N-65, N-85, NPB-195, PM10N, N-10, N-180, N-190, N-20, N-30, NPB-190, NPB-3910, NPB-3920, NPB-3930, NPB-3940, NPB-40, NPB-4000, NPB-75, Sensors that have OxiMax Technology and 9 pins

Mindray: Accutorr Plus, DPM5, DPM6, DPM7, Duo, Passport 12, Passport 2, Passport V, Passport XG, Spectrum, Spectrum OR, Trio, Passport 8, BeneView T1, Expert, Passport, V-Series

ConnectorDB9 9pins blob.png
cable materialPVC Jacket
Cable Diameter3.2mm
cable's Length0.9M or according to customer's requirement
 

Technical parameters

LEDLED660nm normal
Infrared905nm normal
Text RangeOxygen Saturation(%SpO2)0% to 100%
 Pulse Rate(bpm)30 to 245
AccuracySpO2±1%(90~100%)
±2%(80~90%)
±3%(below 70%)
Pulse Rate2bpm(30-250bpm)
Storage Environment-10℃~+40℃
Operating Temperature±5℃~+40℃
Operating/Storage/Transportation Humidity0%-80%
Hyperbaric Pressure86kPa-106kPa

 

Sensor Type 

Adult Non-woven

Adult Foam

Adult/Neonate sponge

Adult Transpore

Pediatric Non-woven

 

Shipment
1. We will ship the item within 1-3 weeks after confirmation of order, kindly leave us your shipping address and

contact number, both are very important.
2. Shipping to all over the world by UPS/DHL/FedEx or other express (5-15days), or sea shipment ( 10-45days),

pls contact us for theshipping rate.If you have any special requirement, please feel free to contact our staff immediately,

we will offer you the satisfy shipping.
3. We will send you the tracking number after shipment, you also can ask us for the tracking service.
4. If you haven't received items in 2-8 weeks after delivery, please contact us immediately.

Hot Products

Reusable Spo2 Sensors Direct Connect Type With DB9 Connector Product Description Compatible monitor ...
Philips Neonatal Spo2 Sensor Compatible With HP MP20 MP40 Product Description Compatible monitor ...
BCI Reusable Spo2 Sensor DB 9 Pin Connector Adult Finger Clip Product Description Compatible monitor ...
Ds100a Oximax Spo2 Sensor 9 Pin Patient Monitor Probe Oximax Spo2 Sensor DS-100A 9pin Patient ...
GE OHMEDA Adult Reusable Spo2 Sensor For GE B20 B60 1M Cable Product Description Compatible with GE ...
Edan MS3 109069 Reusable Adult Spo2 Probe Pulse Oximeter Sensor Product Description Compatible Edan ...