Single Lumen Closed Loop Suction System For 24 Hours

 

 

Closed Suction Catheter can be helpful in limiting environmental, personnel and patient contamination and in preventing the loss of lung volume and the alveolar derecruitment associated with standard suctioning in the severely hypoxemic patients.

 

 

Product Parameter

 

Product CodeSizeColour CodeTube OD (mm)Length of Tube (mm)
MC-02400Neonatal/24H/TracheostomyGrey5Fr(1.7mm)300mm
MC-02401Neonatal//24H/TracheostomyLight Green6Fr(1.95mm)300mm
MC-02402Pediatric/24H/TracheostomyLvory7Fr(2.3mm)300mm
MC-02403Pediatric//24H/TracheostomyLight Blue8Fr(2.7mm)300mm
MC-02404Adult/24H/TracheostomyBlack10Fr(3.35mm)300mm
MC-02405Adult/24H/TracheostomyWhite12Fr(4.05mm)300mm
MC-02406Adult/24H/TracheostomyGreen14Fr(4.75mm)300mm
MC-02407Adult/24H/TracheostomyOrange16Fr(5.45mm)300mm

 

 

 

 

 

 

 

 

 

 

 

 

 

Product CodeSizeColour CodeTube OD (mm)Length of Tube (mm)
MC-02410Neonatal/24H/EndotrachealGrey5Fr(1.7mm)300mm
MC-02411Neonatal//24H/EndotrachealLight Green6Fr(1.95mm)300mm
MC-02412Pediatric/24H/EndotrachealLvory7Fr(2.3mm)300mm
MC-02413Pediatric//24H/EndotrachealLight Blue8Fr(2.7mm)300mm
MC-02414Adult/24H/EndotrachealBlack10Fr(3.35mm)600mm
MC-02415Adult/24H/EndotrachealWhite12Fr(4.05mm)600mm
MC-02416Adult/24H/EndotrachealGreen14Fr(4.75mm)600mm
MC-02417Adult/24H/EndotrachealOrange16Fr(5.45mm)600mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Instructions For Use

 

1. Unlock the thumb control valve

 

2. Stabilize the catheter and endotracheal tube by firmly holding the T-Piece or Elbow with one hand and inserting the catheter into the endotracheal tube or tracheostomy tube by advancing the catheter between the thumb and forefinger of the opposite hand to the desired depth.

 

3. Activate suction by depressing the thumb control valve while gently withdrawing the catheter. Stop when the black band on the catheter is visible in the sheath.

 

4. Release the thumb control valve.

 

5. For subsequent suctioning repeat step 1 to 4

 

6. After the suction procedure rinse the catheter by attaching a saline vial or syringe to the rinse port and gently instill saline or established fluid while depressing the thumb control valve simultaneously.

 

Advantage

 

-Auto-Flushing

 

-Hinged Valve

 

-Unique Blue Soft Tip

 

-Turbulent Cleaning Chamber

 

 

Hot Products

Disposable Liquid Silicone Laryngeal Mask Airway For Emergency Medicine The Laryngeal Mask Device is ...
Regular Silicone Reinforced Laryngeal Mask Airway With 1-5Fr The Laryngeal Mask Device is a type of ...
Flexible Silicone Reinforced Laryngeal Mask Airway For Endotracheal Medical grade silicone for super ...
Disposable Liquid Silicone Laryngeal Mask Airway With Or Without Bar The Laryngeal Mask Device is a ...
#1.0-5.0 Oral Laryngeal Mask With Strengthen Neck And Easier Insertion Color Coding Pilot Balloon ...
Double Lumen Curved Laryngeal Mask With Aspiration Port -Double Lumen Laryngeal Mask Airway Curved ...