ECG300G 3 channel electrocardiography machine ekg ecg machines home ecg devices

 

Introduction

 

ECG300G is an Electrocardiograph which can collect 12-lead ECG signal simultaneously and print waveform by thermal printing system. It features in, recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for “Lead off” and “Lack of paper”, multi-language interface, AC/DC, optional rhythm lead that convenient to observe abnormal heart rhythm, case database management, etc.
Note: The device sold to the countries and regions that have FDA certification requirement does not support automatic analysis and diagnosis function.
 
Function
1)Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
2)Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.
3)Multiply printing modes and formats, including manual, auto 4x3, auto 3x4+1, auto 3x4, auto 2x6+1, auto 2x6, auto 3-2+1, auto 3-2, auto 1x12+1, auto 1x12, rhythm 4, rhythm 3, rhythm 2, etc. Waveform length printed can be adjusted, and with timed print function, which meets different requirements.
4)With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc. which reduces the doctor’s burden.
5)Build-in large capacity memory stores at least to 1000 cases, which is convenient for doctor to review case and statistic.
6)Multi- language(Chinese, English, Spanish, Turkish, Polish, Italian, French, German, Portuguese, Russian, Ukrainian, Serbian, Vietnamese, Slovenian, Slovak, Bulgarian and Nigerian language) interface and report.
 
Performance
Input mode: floating and defibrillation protection
Lead: Standard 12-lead
Patient leakage current: <10 µA
Input impedance: ≥2.5MΩ
Frequency response:
Rated input amplitude Input frequency and waveform Relative output response
1.0 0.67Hz~40Hz, Sine wave ±10%a
0.5 40Hz~100Hz, Sine wave +10 %, -30 %a
0.25 100Hz~150Hz, Sine wave +10 %, -30 %a
0.5 150 Hz ~ 500 Hz, Sine wave +10 %, -100 %a
1.5 ≤1Hz,200ms, Triangle wave +0 %, -10 %b
a relative to 10Hz b relative to 200 ms
Time constant:≥ 3.2s
CMRR: >105dB
Filter: power frequency(AC50/60 Hz), EMG(25 Hz/35 Hz (-3 dB)), baseline drift filter
Recording way: thermal printing system
Specification of recording paper: 80 mm(W)×20 m(L) high-speed thermal paper
Time base selection(paper speed): 12.5 mm/s, 25 mm/s, 50 mm/s, error: ±5%
Gain control(sensitivity): 5, 10, 20 mm/mV, accuracy is ±2%; Standard sensitivity: 10 mm/mV±0.2 mm/mV
Recording mode: auto mode, rhythm mode and manual mode
Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1)
Safety classification: Class I, type CF defibrillation-proof applied part
Polarization resistance voltage: ±610mV
Noise level: ≤12 µVp-p
ECG signal input sampling frequency: 32 kHz
Waveform data processing sampling frequency: 1 kHz
Sampling accuracy: 24-bit
The minimum detection signal: 10 Hz, 20 µV(peak-peak value) deflected sinusoidal signal can be detected
Pacing detection channel: standard II
Accuracy of input signal: ±5%
Amplitude quantization: ≤5µV/LSB
Dimension: 315 mm(L)×215 mm(W)×77 mm(H)
Weight: 1.6 kg
Interchannel time deviation: <100 µs
Power supply:
AC: 100V~240V(50/60Hz)
DC: 7.4V/3500mAh rechargeable lithium battery
Degree of protection against ingress of liquid: IPX0
Working mode: continuous working
 
Accessories
Standard configuration:
A lead cable
A limb electrode
A chest electrode
A thermal recording paper
A power cord
An earth wire
A user manual
 
Physical characteristic
Working environment
Temperature: 5℃~40℃
Relative humidity: 25%~95%(non-condensing)
Atmospheric pressure: 700 hPa~1060 hPa
Transport and storage environment
Temperature: -20 ℃~+55 ℃
Relative humidity: ≤95%
Atmospheric pressure: 500 hPa~1060 hPa
Dimension: 315mm(L)×215mm(W)×77mm(H)
Weight: 1.6Kg
 
ECG

 

 

 

PerformanceECG300GECG600GECG1200G
Screen3.5'' color LCD7'' TFT-LCD8'' TFT-LCD
Power supplyAC/DC,built-in rechargeable lithium battery
Paper speed5,6.25,10,12.5,25,50mm/s +/-5%
Paper size80mm*20m110mm*20m210mm*20m
Dimension315mm(L)*215mm(W)*77mm(H)315mm(L)*215mm(W)*92mm(H)340mm(L)*320mm(W)*85mm(H)
Weight1.6Kg1.7Kg3.2Kg
 

Hot Products

BC401 Urine Analyzer is a high-precision, intellectual instrument which is researched and developed ...
Product Description The charging nano-blue light atomizer needs to be fully charged before use, each ...
Product Description LUBAR SUPPORT DECOMPRESSION BELT Specification item value Place of Origin China ...
Product Description before getting air after getting air The inflatable air column pulls in the up ...
Product Description German hot pressing technology, no glue, continuous line, no deformation, no ...
Product Description Easy traction at home, 30 minutes a day, can effectively relieve cervical ...